LogiCO2 CO2 sensor for cold rooms with reliable detection in low temperatures
The LogiCO2 3349 set is a CO2 detection system for cold rooms and freezers with a Cold Room sensor, Mk9 central unit and sounder/beacon to monitor leaks in cold environments where a conventional detector may lose accuracy.
Qué aporta este producto
This unit is designed for cold rooms and freezing applications where CO2 may accumulate due to a leak and a standard detector does not provide a sufficiently reliable response at low temperature.
The real advantage of this set is that it already includes the core of the system: low-temperature-specific sensor, Mk9 central unit, sounder/beacon, power supply, connectors, signage, and protective cover. This reduces configuration errors and simplifies a technically sound installation.
In addition, the manufacturer states that the Cold Room solution is specially adapted to refrigeration and freezing, and that the sensor differs from the standard Mk90 in its temperature range and in an alarm level configurable via DIP switch 1.
Key data
Artículo fabricante
3349
SKU Install Beer
LG007
Main application
Cold rooms and freezers
Sensor
Cold Room CO2 Sensor
Central unit included
Mk9 central unit
Sensor operating temperature
From -40 °C to 25 °C
Important: this product is aimed at cold environments. If your installation has several risk points or several cold rooms, the manufacturer’s own documentation allows for expansion with additional kits and up to twelve sensors on a single central unit.
Main features
-
Designed for real cold The manufacturer has tailored it specifically for cold rooms and freezers, where a conventional detector may drift more.
-
Complete base set Includes Cold Room sensor, Mk9 central unit, sounder/beacon, power supply, connectors, cabling, manual and signage.
-
Accurate CO2 detection It is designed for safety in environments where a leak may go unnoticed if the sensor is not prepared for low temperature.
-
Professional architecture Uses RS485 Modbus communication, common in technical supervision systems.
-
Expandable Up to twelve sensors can be connected to one central unit and additional kits integrate in plug-and-play mode.
-
Visual and audible alarm The strobe sounder/beacon helps to warn both inside and outside the monitored area.
-
Altitude compensation The sensor can be adjusted to compensate for the installation altitude.
-
Automatic calibration Performs self-calibration several times a year.
Technical specifications
Confirmed technical specifications of the LogiCO2 Cold Room 3349 set
| Parámetro |
Dato confirmado |
| Brand |
LogiCO2 |
| Model |
CO2 Cold Room Mk90 Detector Base SET / CO2 sensor set for cold rooms |
| SKU |
LG007 |
| MPN / artículo fabricante |
3349 |
| Equipment type |
Base CO2 detection system for cold rooms and freezers |
| Application |
Cold room and freezer applications |
| Main components of the set |
CO2 Cold Room Sensor + Central Unit Mk9 + Amber LED glass Horn/Strobe + Power Supply 1A + Protection Cover |
| Sensor reference |
1153 |
| Central unit reference |
1148 |
| Horn/strobe reference |
0440 |
| Power supply reference |
0021 |
| Protective cover reference |
0185 |
| Fuente de alimentación del sistema |
12-24 V CC |
| Communication |
RS485 Modbus |
| Automatic calibration |
Several times a year |
| Sensor ingress protection |
IP54 |
| Temperatura de funcionamiento del sensor |
From -40 °C to 25 °C |
| Preset alarm levels |
5000 ppm awareness indication, 5000 ppm TWA/8 h alarm, 1.5% low alarm, 3.0% high alarm |
| Ajuste adicional |
Compensación de altitud |
| Sirena/baliza tensión nominal |
18–24 V DC |
| Sounder/beacon power consumption |
80 mA peak with 24 V DC supply |
| Sounder/beacon sound level |
110 dB / 1 m |
| Sirena/baliza intensidad del flash |
115 CD |
| Sirena/baliza frecuencia del flash |
65/min |
| Sirena/baliza temperatura ambiente |
From -5 °C to +50 °C |
| Sounder/beacon dimensions |
134 x 115 x 61 mm |
| Sirena/baliza protección |
IP65 |
| Central unit communication |
RS485, Modbus |
| Central unit display |
128x64 graphic display, backlit |
| Central unit audible signal |
80 dBa (1 m) max. |
| Central unit ambient temperature |
From 0 to +40 °C |
| Central unit humidity |
0-90 % sin condensación |
| Central unit dimensions |
90 x 161 x 38 mm |
| Central unit protection |
IP54 according to TÜV, IP44 according to UL |
| Expansion capacity |
Up to 12 sensors connected to a central unit |
| Scope of supply |
CO2 Mk90 incl. one 10 m blue cable and one 5 m red cable, strobe sounder/beacon with amber LED lens with blue indicator incl. 1 m cable and sign, RJ45 1-1 splitter, 1 A transformer, plug lock, bag with 3 gland seals, 6 strips, 24 screws and wall plugs, signs, Mk90 manual, Mk90 quick guide and protective cover. |
| Certificaciones y cumplimiento |
CE, UL, DIN6653-2 2015-06, EN55022:2006/A1:2007, EN55024/A2:2003, EN61000-3-2:2006, EN61000-3-3/A2:2006, AS/NZS CISPR 22:2006, IEC/EN IT55022/55024, LNE Règle de certification NF 128. |
| GTIN/EAN |
Dato no facilitado |
| Weight |
Dato no facilitado |
Compatibility and use cases
This set is designed for cold rooms, freezers, cold storage areas, gas rooms connected to cold rooms and other cold indoor spaces where CO2 is used and there is a risk of accumulation due to leakage.
Suitable for hospitality, food retail, wineries, breweries, beverage producers, the food industry and any facility where CO2 is used in cold rooms or low-temperature enclosures.
The manufacturer’s own documentation allows expansion with additional kits, relay kits and connection to building management systems, always within the LogiCO2 architecture.
Installation and considerations before buying
- El sensor debe instalarse a una altura máxima de 30 cm del suelo y a una distancia máxima de 5 m del punto de distribución de CO2.
- Each sensor covers a maximum area of 78 m²; if the cold room or area is larger, consider additional sensors.
- The sounder/beacon must be placed above the sensor, approximately 2–2.4 m from the floor, clearly visible from any entrance.
- The documentation also recommends installing a second sounder/beacon outside the monitored area, preferably above the access door or doors.
- The central unit must be installed outside the monitored area, in a visible and accessible position.
- Check the available power supply, the RJ45 cable routing and compatibility with the system architecture if you plan future expansions.
- As this is a safety product, installation and commissioning must be carried out with technical expertise and final functional verification.
Recommended maintenance and use
The sensor performs automatic calibration several times a year. Even so, as this is a CO2 safety system, it is advisable to periodically check cables, connectors, visibility of signage, sounder/beacon, and correct reading on the central unit.
The general system documentation recommends that a qualified professional agent perform a functional check at least once a year. Cleaning should be done with water and a damp cloth, avoiding any unauthorised tampering with the equipment.
Frequently asked questions
Is this product for cold rooms and freezers?
Yes. Item 3349 is specifically designed for cold room and freezer applications.
Does it include an Mk9 central unit?
Yes. This base set includes a Cold Room sensor, Mk9 central unit, sounder/beacon, power supply, connectors, manual and signage.
How does it differ from a conventional detector?
The manufacturer’s own datasheet explains that conventional detectors are not designed for cold environments and may have a high margin of error. This sensor is adapted to low temperatures.
Where should the sensor be installed?
It must be mounted at a maximum of 30 cm from the floor and at a maximum of 5 m from the CO2 distribution point. Each sensor covers up to 78 m².
Can the system be expanded?
Yes. The documentation for item 3349 states that up to 12 sensors can be connected to one central unit and that additional kits are installed in plug-and-play mode.
Does it require periodic maintenance?
Yes. Although the sensor performs automatic calibration, it is advisable to carry out periodic functional checks and have a professional inspection at least once a year.