Kit adicional para monitor de potencia LogiCO2 - Install Beer

Additional kit for LogiCO2 power monitor

162.00€ excl. VAT 196.02€ VAT incl.
Skip directly to product information
Kit adicional para monitor de potencia LogiCO2 - Install Beer

Additional kit for LogiCO2 power monitor

LG013
162.00€ excl. VAT 196.02€ VAT incl.
Shipping calculated at checkout.

Pickup available at Install Beer S.L.

Usually ready in 4 hours

View store information

Additional kit for LogiCO2 power monitor

Install Beer S.L.

Pickup available, usually ready in 4 hours

Carrer de Joaquim Valls 109
Local
08042 Barcelona
B
Spain

+34933464656
Monitoring accessory · LogiCO2

LogiCO2 power monitor to signal if the system loses power

The LogiCO2 power monitor add‑on kit monitors the power supply to the safety system and triggers an audible and visual warning if power is cut or if the voltage drops to a critical level.

What this product offers

This accessory is designed for a very specific problem: the LogiCO2 safety system stopping due to loss of power. Instead of relying only on the presence of voltage at the central unit, the monitor provides an independent warning if the system goes out of service.

Its technical value lies in combining power monitoring with an internal backup battery. This allows it to continue providing alerts even when the main power supply is lost, which is especially useful in installations where a power failure must not go unnoticed.

It also makes sense when the system runs on a UPS. If the UPS battery is depleted and the system no longer has 24 V DC, the monitor will indicate this with its own alarm.

Key data

Manufacturer’s part number 0486
SKU Install Beer LG013
Main function System power monitoring
System power supply 24 V DC
Internal backup 2 alkaline AAA batteries
Alarm autonomy At least 12 hours
Important: this product does not detect gas. Its function is to warn when the LogiCO2 safety system loses power or drops to an insufficient voltage level.

Main features

  • Power supervision Monitors whether the safety system has proper power or loses it completely.
  • Low-voltage alarm Also alerts when the voltage drops below 18 V, before total failure.
  • Built-in buzzer Includes a local audible alarm so that any incident is clearly noticeable.
  • Backup battery Uses two included alkaline AAA cells to keep providing alerts during a power outage.
  • Minimum alarm autonomy The manufacturer specifies an audible warning for at least 12 hours in case of power failure.
  • Clear LED indicators Green for normal power, red for fault or low voltage, and yellow for low batteries.
  • Flexible connection It can be connected to the safety system’s red or blue cable.
  • Useful with UPS Also recommended for monitoring the operation of a system powered via UPS.

Technical specifications

Confirmed technical specifications of the LogiCO2 power monitor add‑on kit
Parameter Confirmed data
Brand LogiCO2
Model Power Monitor Add-on KIT
SKU LG013
MPN / manufacturer part number 0486
Equipment type Power monitor for LogiCO2 Safety System
Function Alert staff if a power failure puts the safety system out of service
Power supply from system 24 V DC
Internal battery 2 x 1.5 V AAA alkaline batteries
Battery check Once per hour
Low-voltage activation point 18 V
Activation point on loss of power Approximately 3 V
Connections RJ45
Sound signal level Approximately 80 dBA (1 m)
Operating temperature 0 to +45 °C
Use Indoor use only
Overvoltage Category II
Approval UL certified
Dimensions 90 x 161 x 38 mm
Ingress protection IP54
Scope of supply Power monitor for LogiCO2 safety systems, incl. cable
Note on batteries Do not use lithium or rechargeable batteries
Weight 1 Kg

Compatibility and use cases

This monitor is designed for the LogiCO2 Safety System and can be connected to either the system’s red cable or blue cable.

It is useful in installations where a power loss must not go unnoticed: hospitality, wineries, breweries, technical rooms, light industrial facilities and systems with UPS.

It is especially recommended when you want to add an extra layer of monitoring to the power supply of the safety system itself.

Installation and considerations before buying

  • Install it in a place where it is easy to see and hear, preferably next to the central unit.
  • It must not be covered by other mounting elements.
  • It can be connected directly to the central unit or via a splitter to the red or blue cable of the system.
  • For commissioning without triggering a low-battery alarm, both batteries must be installed within 30 seconds after reconnecting the unit’s power cable.
  • Before buying, check whether you need monitoring of power failure for the entire system or a different signaling accessory, because this product does not replace an external siren or a sensor.
  • If the system uses a UPS, this monitor is especially recommended to supervise depletion of the UPS battery.

Recommended maintenance and use

As a safety product, the manufacturer recommends a functional check at least once a year. The test consists of disconnecting the power supply to the safety system and checking that the “no power” audible alarm and the red LED are activated, then reconnecting the power supply.

When the batteries are depleted, they must be replaced following the specified procedure: disconnect the monitor’s power cable, reconnect it, and install the two new batteries within 30 seconds. The manufacturer recommends high‑performance AAA alkaline batteries and advises against lithium or rechargeable batteries.

Frequently asked questions

What exactly is the LogiCO2 Power Monitor for?

It is used to signal if the LogiCO2 safety system loses power or if the voltage drops too low.

Does it detect CO2 or O2?

No. It is not a gas sensor; it is a power monitor for the safety system.

Does it include batteries?

Yes. The manufacturer specifies space for two alkaline AAA batteries and includes the batteries in the set.

How long can it sound in the event of a power cut?

The manufacturer states that it can maintain the audible alarm for at least 12 hours.

Where should it be installed?

It must be mounted in a visible and audible location, preferably next to the central unit, and must not be covered.

Can it be connected to the red cable or the blue one?

Yes. The documentation states that it can detect power failure on both the red and the blue cable of the safety system.

Shipping: check availability, lead time and applicable cost before completing your order.

Terms: see the shipping, returns and warranty pages for the applicable conditions.

Buy technical products with confidence

Confirm compatibility before purchasing

With dispensing components, a few millimetres, a thread or the beverage type can determine compatibility. Review the description and contact us when you do not have all the details.

01

Application

Beverage, location, expected flow and installation type.

02

Connection

Thread, hose barb, push-fit connector, internal and external diameter.

03

Conditions

Pressure, gas, temperature, material and cleaning requirements.

04

Contents

Check which accessories, seals or adapters are included.