Kit adicional de válvula de seguridad y SMB LogiCO2 para sistemas CO2 - Install Beer

Additional LogiCO2 safety valve and SMB kit for CO2 systems

378.00€ EUR (457.38€ EUR IVA incl.)
Skip directly to product information
Kit adicional de válvula de seguridad y SMB LogiCO2 para sistemas CO2 - Install Beer

Additional LogiCO2 safety valve and SMB kit for CO2 systems

LG010
378.00€ EUR (457.38€ EUR IVA incl.)

Pickup available at Install Beer S.L.

Usually ready in 4 hours

View store information

Additional LogiCO2 safety valve and SMB kit for CO2 systems

Install Beer S.L.

Pickup available, usually ready in 4 hours

Carrer de Joaquim Valls 109
Local
08042 Barcelona
B
Spain

+34933464656
CO2 Safety · LogiCO2

LogiCO2 SMB safety valve to shut off CO2 in case of leak

The LogiCO2 SMB and safety valve add‑on kit automatically shuts off CO2 distribution when an Mk9 or Mk90 sensor detects a high concentration, helping to limit the leak from the start of the gas line.

What this product offers

This accessory is designed to add an active safety measure to the LogiCO2 system: not only detecting a leak, but also shutting off the gas supply when an alarm occurs.

Its technical value lies in the fact that the solenoid valve acts on the CO2 distribution and operates in fail-safe mode. This means that if power is lost, the valve closes.

In a real installation, this helps reduce the risk of continuing to feed a leak from the cylinder or tank into the distribution line.

Key data

Manufacturer’s part number 0476
SKU Install Beer LG010
Compatibility LogiCO2 Mk9 and Mk90 CO2 systems
Working pressure 0.15 to 30 bar
Threaded connection 1/4"–18 NPT
Safety mode Fail‑safe, power‑off closing
Important note: this product does not replace the detector or the central unit. It is an additional accessory that acts on the gas line when the LogiCO2 system detects a leak.

Main features

  • Automatic CO2 shut-off Shuts off the gas supply when the sensor detects a high CO2 concentration.
  • Fail‑safe valve It closes in the event of power loss, adding a layer of passive safety.
  • Compatible with Mk9 and Mk90 Designed as an accessory for LogiCO2 Mk9 and Mk90 CO2 safety systems.
  • Blue RJ45 signal output The electronic box connects to the sensor’s blue alarm signaling side.
  • Factory setting on high alarm Supplied configured to close on high alarm, with the option to change it to low/pre-alarm via jumper.
  • Visual status indicator Includes a red indicator showing that the valve is open.
  • Compact format Electronic enclosure 78 x 78 x 37 mm, easy to integrate into technical rooms.
  • Installation near the cylinder The manufacturer recommends installing it as early as possible in the distribution chain, near the CO2 tank.

Technical specifications

Confirmed technical specifications of the additional LogiCO2 safety valve and SMB KIT
Parameter Confirmed data
Brand LogiCO2
Model SMB Safety Valve Add-on KIT
SKU LG010
MPN / manufacturer part number 0476
Equipment type Fail‑safe box with safety valve for CO2 safety system
Compatibility LogiCO2 Mk9 and Mk90 CO2 safety system
Function Shut off CO2 gas distribution in case of a leak
Valve type Magnetic safety shutoff valve
Fail‑safe mode Yes, the valve closes in the event of power loss
Fuente de alimentación Through the CO2 sensor
Relés 1A / 24 V CA/CC
Material PC/ABS
Operating pressure 0.15 to 30 bar / 2.2 to 435 psi
Burst pressure >150 bar / 2175 psi
Threaded connection 1/4"–18 NPT
Dimensions 78 x 78 x 37 mm
Ingress protection IP55
Wired 1 m Cat. 5 cable from the electronics box with blue RJ45 connector
Factory setting High‑alarm shutoff
Configurable setting It can be changed to close on low alarm/pre-alarm
Status indicator Red indicator; lit means valve open
Scope of supply SMB + safety shut-off valve + 1 m cable; the datasheet also states delivery with 1-4 RJ45 splitter and the official page specifies valve without filter

Compatibility and use cases

This kit is intended for CO2 installations where a LogiCO2 Mk9 or Mk90 system is already in place and you want to add automatic gas shutoff in the event of a leak.

It is suitable for hospitality, wineries, breweries, cold rooms, technical rooms and any installation where the CO2 cylinder or tank feeds a distribution network and it is advisable to interrupt the supply in case of alarm.

It also makes sense when the project includes a central unit, sensors, horn/beacon, and other safety accessories within the LogiCO2 architecture.

Installation and considerations before buying

  • The solenoid valve must be installed as early as possible in the gas distribution line, close to the CO2 tank or cylinder.
  • The electronic box must be mounted in a mechanically protected location.
  • The connection is made using the blue RJ45 connector on the blue alarm signaling output side of the Mk9 or Mk90 sensor.
  • Before purchasing, confirm the thread of the installation: 1/4”-18NPT.
  • Also check the actual working pressure of the circuit, which must be within 0.15 to 30 bar.
  • If the installation design is large or has many accessories, it is advisable to review the total system consumption and the power distribution within the LogiCO2 architecture.
  • As safety equipment, installation and commissioning must be carried out with technical criteria and final functional verification.

Recommended maintenance and use

The manufacturer recommends an annual functional check. To test the valve, the indicator must be lit, which shows that the valve is open.

The test is carried out by pressing the test button on the SMB junction box: the indicator light must go out and the valve must make a clear clicking sound. After any intervention in the system, it is advisable to repeat this check.

Frequently asked questions

What exactly is the SMB with safety valve used for?

It is used to automatically shut off CO2 distribution when the LogiCO2 system detects a leak or a high concentration.

Is it compatible with any detector?

No. It is designed as an accessory for LogiCO2 CO2 Mk9 and Mk90 systems.

Where should the valve be installed?

It must be installed as close as possible to the CO2 tank or cylinder, at the start of the distribution chain.

What happens if the power supply is cut?

The valve is fail-safe, so it closes in the event of a power loss.

Is it configured for high alarm or low alarm?

From the factory it is configured to close on high alarm, although it can be adjusted to operate on low alarm or pre‑alarm.

How do you check that it is working correctly?

The manufacturer recommends an annual test: with the indicator lit, press the test button on the SMB; the indicator should go out and you should hear a click from the valve.

Fast and secure shipping (24h express)

Flexible returns (14-day period)

3-year warranty (6 months for businesses)

Essential accessories

You might also be interested in

Frequently asked product questions

Is this product compatible with my setup?

It depends on the type of connector/head, threads, and tube diameter. If you provide us with your configuration or send us a photo, we can confirm compatibility.

What measurements should I check before buying?

Thread type, inner/outer tube diameter, fitting type (quick-connect/barb/threaded), and whether it’s for beer, gas, or water line.

Does it include gaskets, clamps, or the necessary accessories?

The description specifies what is included. If you need additional seals or accessories, we’ll recommend compatible options.

What material is it made of and what use is it recommended for?

The material (stainless steel, brass, etc.) is designed for food-grade and dispensing use. If you’re going to use it with another beverage or under special conditions, we’ll advise you.

Is it easy to install? What tools do I need?

It’s usually a straightforward installation, but we recommend a clean cut on the tubing, proper tightening, and leak testing. We’ll indicate the method according to the type of connection.

How do I know if the thread or fitting is the right one?

The key is to identify your system’s thread standard and connection type. If you’re unsure, send us a photo of the current part and we’ll help you choose.

What should I do if I have leaks after assembling it?

It’s usually due to a worn gasket, incorrect measurement, poorly cut tubing, or insufficient sealing. We’ll help you diagnose and fix it.

Does this component affect foam or serving flow rate?

Yes, some components affect flow and stability. If you’re having issues with foam or flow rate, we’ll help you balance pressure, temperature, and line.

How often should I check or replace gaskets and consumables?

It depends on usage and cleaning, but it’s advisable to check them regularly to avoid leaks and maintain a stable, hygienic service.

Do you offer technical support and international shipping?

Yes. We advise you before and after purchase and provide technical service. We also ship throughout Europe and to North, Central, and South America.