Cooler agitator for cold water recirculation
Pickup available at Install Beer S.L.
Usually ready in 4 hours
Cooler agitator for recirculating cold water and protecting the line
This agitator is installed in coolers with a cold-water circuit to keep the water moving inside the tank and push it towards the recirculation outlets. Its function is highly technical and specific: to prevent the water inside from freezing and to help maintain the temperature in the line up to the point of service.
In beer and other tap beverage installations, thermal stability of the line is crucial to reduce issues, improve service and work more consistently. A suitable agitator does not chill the drink by itself: it makes it possible for the chilled water to do its job properly within the system.
This replacement part is intended for both professional environments and compatible home installations, especially when working with coolers with an ice bank and a recirculation line to the column, tap or service area.
How to choose a variant
Water outlets · 3
| SKU | Stages |
|---|---|
| IB0061 | 1 |
| IB0062 | 2 |
Compatibility and use cases
Technical compatibility
This agitator is intended for ice bank coolers that work with chilled water circulation. The published compatibility includes models V-50, V-100, V-200, H-100 and H-200keg system.
Its job is not to drive the beverage, but the cold water in the circuit. That’s why it fits systems where the product line needs recirculation support up to the column, tap or remote run.
Typical scenarios
A useful replacement part for bars, restaurants, breweries, brewpubs, events and compatible home installations with a tap and a cooler with water bath.
It may be suitable for beer and other tap-dispensed beverages as long as the system uses recirculating cold water to keep the line stable.
Installation
- Check that your cooler is compatible with the listed models or an equivalent ice-bank and water-recirculation system.
- Check the available power supply: 220 V / 50 Hzkeg system.
- Check whether you need 1 or 2 stages depending on the distance, resistance of the circuit and the demands of the cold-water return.
- Confirm that the 3 outlets and the 7 x 10 mm tube match your current circuit.
- Check whether your original assembly works with an external capacitor. This reference does not integrate it into the chassis.
- Before replacing it, it’s advisable to check the condition of the impeller, turbine, wiring, and existing connections.
- If you are not used to this type of spare part, installation by a service technician reduces assembly errors and subsequent downtime.
Good practice
For reliable operation, the agitator must run in a clean, unobstructed circuit. It is advisable to periodically check the condition of the bath water, accumulated dirt, impeller rotation, motor noise and the condition of the outlet tubes. Poor recirculation can lead to worse thermal stability in the line.
For replacement or inspection tasks, always disconnect the power supply and check the actual start-up of the assembly once mounted. If your system uses an independent capacitor, it is also advisable to check it when symptoms of irregular start-up or loss of performance appear.
Tools and documentation
Golderos distinguishes G98 versions by capacitor configuration and pump stage. Check the variant and motor nameplate before ordering.
Frequently asked questions
Is this agitator compatible with my cooler?
The listed compatible models are V-50, V-100, V-200, H-100 and H-200. For another model, confirm the dimensions, power supply, outlets and mounting system before buying.
Does it include a start capacitor?
No. This reference corresponds to the version without integrated capacitor. If your machine requires one, you must check the compatible capacitor or the agitator version with capacitor.
What’s the difference between 1 stage and 2 stages?
The difference lies in the pushing power available for recirculation. The choice depends on the distance and the demands of the cold‑water circuit.
Is it suitable for pumping beer or wine?
No. This agitator moves chilled water inside the cooling system. It is not a direct pump for the beverage.
What should I check before buying?
Machine model, electrical voltage, need for an external capacitor or not, number of outlets, tube size, impeller mounting and available space.
Is installation easy?
For a technician familiar with coolers and dispensing spare parts, it is usually a manageable replacement. If you do not know the circuit or the wiring, it is preferable to install it with technical support.
Accessories and add-ons
Technical information
| Property | Detail |
|---|---|
| Product | Refrigeration machine agitator |
| Model | Cooler agitator, 3 outlets |
| MPN | 1200020013 and 1200020014 |
| Equipment type | Spare part / agitator for recirculation of chilled water in an ice bank machine |
| Version | Without integrated capacitor |
| Available stages | 1 stage or 2 stages, depending on variant |
| Number of outlets | 3 chilled water outlets |
| Main function | Keep the water moving to prevent freezing and to drive water through the tube cooling outlets |
| Overall dimensions | 150 x 120 x 270 mm |
| Weight | 2,500 g |
| Materials | Metal and plastic; outlets specified for 7 x 10 mm clear PVC tube |
| Connections / installation notes | According to the published information, it can be mounted with any type of connection and impeller |
| Outputs | Clear PVC tube, 7 x 10 mm |
| Impeller | 8 mm, 50 mm diameter, for M6 |
| Pump | Gol-98 |
| Turbine | Gol-92, 9 mm diameter |
| Motor | EBM M2E068-CF10-17 |
| Power supply | 220 V / 50 Hz / 55 W / 0.26 A / F-V 2/450 |
| Published compatibility | V-50, V-100, V-200, H-100 and H-200 beer coolers |
| Scope of supply | Agitator according to selected variant |
| Color / finish | Chrome and black |
| Certifications | Patent AGG98113 |
Useful accessories and add-ons
Check the correct connections and sizes.
Technical information
Information to choose, install and maintain this product
Typical applications
- A useful replacement part for bars, restaurants, breweries, brewpubs, events and compatible home installations with a tap and a cooler with water bath.
- It may be suitable for beer and other tap-dispensed beverages as long as the system uses recirculating cold water to keep the line stable.
Compatibility
Its job is not to drive the beverage, but the cold water in the circuit. That’s why it fits systems where the product line needs recirculation support up to the column, tap or remote run.
Technical specifications
Select a variant to see its technical specifications.
- Tube size
- 7 × 10 mm (outlet tubes)
- Thread
- Connection
- 3 recirculation outlets
- Pressure
- Temperature
- Dimensions
- 150 × 120 × 270 mm
Installation and commissioning
Check the available power supply: 220 V / 50 Hzkeg system.
Check whether you need 1 or 2 stages depending on the distance, resistance of the circuit and the demands of the cold-water return.
Confirm that the 3 outlets and the 7 x 10 mm tube match your current circuit.
Check whether your original assembly works with an external capacitor. This reference does not integrate it into the chassis.
Before replacing it, it’s advisable to check the condition of the impeller, turbine, wiring, and existing connections.
If you are not used to this type of spare part, installation by a service technician reduces assembly errors and subsequent downtime.
Maintenance
For replacement or inspection tasks, always disconnect the power supply and check the actual start-up of the assembly once mounted. If your system uses an independent capacitor, it is also advisable to check it when symptoms of irregular start-up or loss of performance appear.
Product FAQs
The listed compatible models are V-50, V-100, V-200, H-100 and H-200. For another model, confirm the dimensions, power supply, outlets and mounting system before buying.
Does it include a start capacitor?
No. This reference corresponds to the version without integrated capacitor. If your machine requires one, you must check the compatible capacitor or the agitator version with capacitor.
What’s the difference between 1 stage and 2 stages?
The difference lies in the pushing power available for recirculation. The choice depends on the distance and the demands of the cold‑water circuit.
Is it suitable for pumping beer or wine?
No. This agitator moves chilled water inside the cooling system. It is not a direct pump for the beverage.
What should I check before buying?
Machine model, electrical voltage, need for an external capacitor or not, number of outlets, tube size, impeller mounting and available space.
Is installation easy?
For a technician familiar with coolers and dispensing spare parts, it is usually a manageable replacement. If you do not know the circuit or the wiring, it is preferable to install it with technical support.