Additional kit for LogiCO2 power monitor
Pickup available at Install Beer S.L.
Usually ready in 4 hours
LogiCO2 power monitor to signal if the system loses power
The LogiCO2 power monitor add‑on kit monitors the power supply to the safety system and triggers an audible and visual warning if power is cut or if the voltage drops to a critical level.
What this product offers
This accessory is designed for a very specific problem: the LogiCO2 safety system stopping due to loss of power. Instead of relying only on the presence of voltage at the central unit, the monitor provides an independent warning if the system goes out of service.
Its technical value lies in combining power monitoring with an internal backup battery. This allows it to continue providing alerts even when the main power supply is lost, which is especially useful in installations where a power failure must not go unnoticed.
It also makes sense when the system runs on a UPS. If the UPS battery is depleted and the system no longer has 24 V DC, the monitor will indicate this with its own alarm.
Key data
Main features
- Power supervision Monitors whether the safety system has proper power or loses it completely.
- Low-voltage alarm Also alerts when the voltage drops below 18 V, before total failure.
- Built-in buzzer Includes a local audible alarm so that any incident is clearly noticeable.
- Backup battery Uses two included alkaline AAA cells to keep providing alerts during a power outage.
- Minimum alarm autonomy The manufacturer specifies an audible warning for at least 12 hours in case of power failure.
- Clear LED indicators Green for normal power, red for fault or low voltage, and yellow for low batteries.
- Flexible connection It can be connected to the safety system’s red or blue cable.
- Useful with UPS Also recommended for monitoring the operation of a system powered via UPS.
Technical specifications
| Parameter | Confirmed data |
|---|---|
| Brand | LogiCO2 |
| Model | Power Monitor Add-on KIT |
| SKU | LG013 |
| MPN / manufacturer part number | 0486 |
| Equipment type | Power monitor for LogiCO2 Safety System |
| Function | Alert staff if a power failure puts the safety system out of service |
| Power supply from system | 24 V DC |
| Internal battery | 2 x 1.5 V AAA alkaline batteries |
| Battery check | Once per hour |
| Low-voltage activation point | 18 V |
| Activation point on loss of power | Approximately 3 V |
| Connections | RJ45 |
| Sound signal level | Approximately 80 dBA (1 m) |
| Operating temperature | 0 to +45 °C |
| Use | Indoor use only |
| Overvoltage | Category II |
| Approval | UL certified |
| Dimensions | 90 x 161 x 38 mm |
| Ingress protection | IP54 |
| Scope of supply | Power monitor for LogiCO2 safety systems, incl. cable |
| Note on batteries | Do not use lithium or rechargeable batteries |
| Weight | 1 Kg |
Compatibility and use cases
This monitor is designed for the LogiCO2 Safety System and can be connected to either the system’s red cable or blue cable.
It is useful in installations where a power loss must not go unnoticed: hospitality, wineries, breweries, technical rooms, light industrial facilities and systems with UPS.
It is especially recommended when you want to add an extra layer of monitoring to the power supply of the safety system itself.
Installation and considerations before buying
- Install it in a place where it is easy to see and hear, preferably next to the central unit.
- It must not be covered by other mounting elements.
- It can be connected directly to the central unit or via a splitter to the red or blue cable of the system.
- For commissioning without triggering a low-battery alarm, both batteries must be installed within 30 seconds after reconnecting the unit’s power cable.
- Before buying, check whether you need monitoring of power failure for the entire system or a different signaling accessory, because this product does not replace an external siren or a sensor.
- If the system uses a UPS, this monitor is especially recommended to supervise depletion of the UPS battery.
Recommended maintenance and use
As a safety product, the manufacturer recommends a functional check at least once a year. The test consists of disconnecting the power supply to the safety system and checking that the “no power” audible alarm and the red LED are activated, then reconnecting the power supply.
When the batteries are depleted, they must be replaced following the specified procedure: disconnect the monitor’s power cable, reconnect it, and install the two new batteries within 30 seconds. The manufacturer recommends high‑performance AAA alkaline batteries and advises against lithium or rechargeable batteries.
Frequently asked questions
What exactly is the LogiCO2 Power Monitor for?
It is used to signal if the LogiCO2 safety system loses power or if the voltage drops too low.
Does it detect CO2 or O2?
No. It is not a gas sensor; it is a power monitor for the safety system.
Does it include batteries?
Yes. The manufacturer specifies space for two alkaline AAA batteries and includes the batteries in the set.
How long can it sound in the event of a power cut?
The manufacturer states that it can maintain the audible alarm for at least 12 hours.
Where should it be installed?
It must be mounted in a visible and audible location, preferably next to the central unit, and must not be covered.
Can it be connected to the red cable or the blue one?
Yes. The documentation states that it can detect power failure on both the red and the blue cable of the safety system.
Downloadable
Shipping: check availability, lead time, and applicable cost before completing your order.
Terms: see the shipping, returns, and warranty pages for the applicable conditions.
Structured technical information
Information to choose, install and maintain this product
Technical specifications
Select a variant to see its technical specifications.
- Tube size
- Thread
- Connection
- RJ45
- Pressure
- Temperature
- 0–45 °C
- Dimensions
- 90 × 161 × 38 mm