{"product_id":"kit-4a-unidad-central-co2-logico2-mk9","title":"Kit adicional de unidade central A4 de sensores de CO2 LogiCO2 Mk9","description":"\u003csection class=\"iblgmk9-product iblgmk9-central\" data-brand=\"LogiCO2\" data-model=\"Mk9 Central Unit Add-on KIT\"\u003e\n  \u003cstyle\u003e\n    .iblgmk9-product{\n      --ib-max:1120px;\n      --ib-text:#1f2328;\n      --ib-muted:#5b6573;\n      --ib-line:#e6e8eb;\n      --ib-soft:#f7f8fa;\n      --ib-soft2:#f2f4f6;\n      --ib-accent:#111111;\n      --ib-radius:18px;\n      --ib-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ib-content-size:16px;\n      --ib-content-lh:1.68;\n      --ib-h2-size:28px;\n      --ib-h3-size:20px;\n      color:var(--ib-text);\n      font-size:var(--ib-content-size);\n      line-height:var(--ib-content-lh);\n    }\n    .iblgmk9-product *{box-sizing:border-box}\n    .iblgmk9-wrap{max-width:var(--ib-max);margin:0 auto;padding:4px 0 36px}\n    .iblgmk9-hero,.iblgmk9-block,.iblgmk9-specs,.iblgmk9-faq,.iblgmk9-downloads,.iblgmk9-related{\n      background:#fff;border:1px solid var(--ib-line);border-radius:var(--ib-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ib-shadow)\n    }\n    .iblgmk9-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ib-line);\n      border-radius:999px;background:var(--ib-soft);color:var(--ib-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblgmk9-product h2{\n      font-size:var(--ib-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ib-accent)\n    }\n    .iblgmk9-product h3{\n      font-size:var(--ib-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ib-accent)\n    }\n    .iblgmk9-product p{margin:0 0 14px;font-size:var(--ib-content-size);line-height:var(--ib-content-lh)}\n    .iblgmk9-product p:last-child{margin-bottom:0}\n    .iblgmk9-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ib-soft);border:1px solid var(--ib-line)\n    }\n    .iblgmk9-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblgmk9-card{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:var(--ib-soft)\n    }\n    .iblgmk9-card strong{display:block;margin-bottom:6px;color:var(--ib-accent)}\n    .iblgmk9-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ib-accent);\n      background:var(--ib-soft2);border-radius:12px\n    }\n    .iblgmk9-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblgmk9-list-grid li{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:#fff\n    }\n    .iblgmk9-list-grid li strong{display:block;margin-bottom:6px}\n    .iblgmk9-bullets{margin:0;padding-left:18px}\n    .iblgmk9-bullets li{margin:0 0 10px}\n    .iblgmk9-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblgmk9-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ib-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblgmk9-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ib-accent)\n    }\n    .iblgmk9-table thead th{\n      background:var(--ib-soft2);color:var(--ib-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);font-size:15px\n    }\n    .iblgmk9-table tbody th,.iblgmk9-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblgmk9-table tbody th{width:32%;background:#fcfcfd;font-weight:700;color:var(--ib-accent)}\n    .iblgmk9-table tbody tr:last-child th,.iblgmk9-table tbody tr:last-child td{border-bottom:none}\n    .iblgmk9-download-grid,.iblgmk9-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblgmk9-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ib-accent);text-decoration:none;color:var(--ib-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblgmk9-btn:hover{transform:translateY(-1px);box-shadow:var(--ib-shadow)}\n    .iblgmk9-faq details{\n      border:1px solid var(--ib-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblgmk9-faq details:last-child{margin-bottom:0}\n    .iblgmk9-faq summary{cursor:pointer;font-weight:700;color:var(--ib-accent)}\n    .iblgmk9-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblgmk9-cards,.iblgmk9-list-grid,.iblgmk9-download-grid,.iblgmk9-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblgmk9-product{\n        --ib-content-size:15px;\n        --ib-h2-size:23px;\n        --ib-h3-size:18px;\n      }\n      .iblgmk9-hero,.iblgmk9-block,.iblgmk9-specs,.iblgmk9-faq,.iblgmk9-downloads,.iblgmk9-related{\n        padding:18px;border-radius:16px\n      }\n      .iblgmk9-table{min-width:100%;border:0}\n      .iblgmk9-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblgmk9-table,.iblgmk9-table tbody,.iblgmk9-table tr,.iblgmk9-table th,.iblgmk9-table td{\n        display:block;width:100%\n      }\n      .iblgmk9-table tr{\n        border:1px solid var(--ib-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblgmk9-table tbody th{\n        background:var(--ib-soft2);border-bottom:1px solid var(--ib-line)\n      }\n      .iblgmk9-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblgmk9-wrap\"\u003e\n    \u003cdiv class=\"iblgmk9-hero\"\u003e\n      \u003cdiv class=\"iblgmk9-kicker\"\u003eSeguridad CO2 · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eUnidade central de CO2 LogiCO2 Mk9 para controlar e supervisionar o sistema\u003c\/h2\u003e\n      \u003cp class=\"iblgmk9-snippet\"\u003e\u003cstrong\u003eO kit 4A de unidade central de CO2 LogiCO2 Mk9 é a central de controlo do sistema de segurança de CO2: recebe dados dos sensores, mostra alarmes, TWA e temperatura e permite supervisionar o funcionamento geral da instalação.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eQué aporta este producto\u003c\/h2\u003e\n      \u003cp\u003eEsta unidade central foi concebida para instalações LogiCO2 onde já existam sensores ou onde se vá ampliar um sistema de segurança de CO2. A sua função não é detetar por si só, mas centralizar a informação dos sensores, mostrar o estado do sistema e gerir a sinalização de alarme e de erro.\u003c\/p\u003e\n      \u003cp\u003eÉ especialmente indicado para hotelaria, salas técnicas, adegas, cervejarias, produtores de bebidas e qualquer espaço interior onde o CO2 é utilizado, armazenado ou distribuído e em que se requer uma supervisão mais organizada do que a de um sensor autónomo isolado.\u003c\/p\u003e\n      \u003cp\u003eDo ponto de vista operacional, proporciona leitura centralizada, controlo visual do sistema, aviso acústico, botão de silenciamento e reinício, e identificação do sensor que está a gerar a leitura ou o alarme.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eDados-chave\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-cards\"\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          0328\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG005\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eTipo de equipamento\u003c\/strong\u003e\n          Unidade central de sistema de segurança de CO2\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eComunicação\u003c\/strong\u003e\n          RS485 Modbus\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eEcrã\u003c\/strong\u003e\n          LCD de matriz de pontos 128x64\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eAlimentação\u003c\/strong\u003e\n          12-24 V CC\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblgmk9-note\"\u003e\n        \u003cstrong\u003eImportante:\u003c\/strong\u003e a ficha específica do kit 0328 fala em supervisão de até 8 sensores, enquanto a documentação geral do sistema Mk9\/Mk90 mostra configurações de até 12 sensores. Se o teu projeto ultrapassar 8 sensores, convém confirmar a configuração exata antes de comprar.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eCaracterísticas principais\u003c\/h2\u003e\n      \u003cul class=\"iblgmk9-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSupervisão centralizada\u003c\/strong\u003e Mostra resultados, alarmes e incidências dos sensores ligados num único ponto de controlo.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eControlo do sistema\u003c\/strong\u003e A unidade central supervisiona o funcionamento geral e mostra erros quando é detetada uma falha.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLeitura clara no ecrã\u003c\/strong\u003e Visualiza CO2, TWA e temperatura; se houver vários sensores, identifica de qual provém cada leitura.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBotão de silenciamento e reinício\u003c\/strong\u003e Permite silenciar o avisador acústico e reiniciar o alarme após resolvido o incidente.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicadores LED de estado\u003c\/strong\u003e LED verde de funcionamento, LED amarelo de erro e LED vermelho de alarme ou alerta.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompatibilidade com sensores LogiCO2\u003c\/strong\u003e Concebida para ligar sensores fixos LogiCO2; a página oficial também indica compatibilidade com sensores MkVII antigos.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eComunicação industrial\u003c\/strong\u003e Usa RS485 Modbus, uma arquitetura habitual em sistemas de supervisão técnica.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMultilingue\u003c\/strong\u003e A documentação do produto indica 19 idiomas e a página oficial enumera múltiplos idiomas, incluindo o espanhol.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-specs\"\u003e\n      \u003ch2\u003eEspecificações técnicas\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-table-wrap\"\u003e\n        \u003ctable class=\"iblgmk9-table\"\u003e\n          \u003ccaption\u003eEspecificações técnicas confirmadas do kit 4A de unidade central de CO2 LogiCO2 Mk9\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarca\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModelo\u003c\/th\u003e\n              \u003ctd\u003eMk9 Central Unit Add-on KIT \/ Kit de unidade central de CO2 Mk9 4A\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG005\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e0328\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTipo de equipamento\u003c\/th\u003e\n              \u003ctd\u003eUnidade central para sistema de segurança de CO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFunção principal\u003c\/th\u003e\n              \u003ctd\u003eSupervisionar sensores LogiCO2, mostrar leituras e alarmes e controlar o funcionamento do sistema\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCapacidade declarada na ficha do kit 0328\u003c\/th\u003e\n              \u003ctd\u003eHasta 8 sensores\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCapacidade indicada na documentação geral Mk9\/Mk90\u003c\/th\u003e\n              \u003ctd\u003eConfigurações de 1 a 12 sensores no manual e até 12 sensores na página geral do produto\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAlimentação\u003c\/th\u003e\n              \u003ctd\u003e12-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConsumo de corrente\u003c\/th\u003e\n              \u003ctd\u003e35 mA segundo ficha 0328\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eComunicação\u003c\/th\u003e\n              \u003ctd\u003eRS485, Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEcrã\u003c\/th\u003e\n              \u003ctd\u003eLCD de matriz de pontos 128x64\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIntensidade do sinal acústico\u003c\/th\u003e\n              \u003ctd\u003e70 dB (1 m) máx.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura ambiente\u003c\/th\u003e\n              \u003ctd\u003e0-40 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUmidade\u003c\/th\u003e\n              \u003ctd\u003e0–90 % sem condensação\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtección contra penetración\u003c\/th\u003e\n              \u003ctd\u003eIP54 conforme ficha 0328\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensões\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePeso\u003c\/th\u003e\n              \u003ctd\u003eDado não fornecido\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLigações\u003c\/th\u003e\n              \u003ctd\u003eCablagem RJ45 para alimentação, comunicação e sinalização\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIndicadores\u003c\/th\u003e\n              \u003ctd\u003eLED verde de alimentação, LED amarelo de erro e LED vermelho de alarme\/alerta\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLeituras apresentadas\u003c\/th\u003e\n              \u003ctd\u003eCO2, TWA (ppm) e temperatura; também identifica o sensor que origina a leitura ou o alarme\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBotão frontal\u003c\/th\u003e\n              \u003ctd\u003eSilenciamento, restabelecimento e teste\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIdiomas\u003c\/th\u003e\n              \u003ctd\u003eMultilíngue; a ficha 0328 indica 19 idiomas\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCompatibilidade\u003c\/th\u003e\n              \u003ctd\u003eSensores LogiCO2 para instalação fixa; a página oficial indica ainda compatibilidade com sensores MkVII antigos\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConteúdo do fornecimento\u003c\/th\u003e\n              \u003ctd\u003eUnidade central de CO2 Mk9, 1 cabo vermelho de 5 m, divisor RJ45 1-2, placa do sistema de segurança de CO2 Mk9, manual\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCertificações e conformidade\u003c\/th\u003e\n              \u003ctd\u003eCE, ensaios segundo SS-EN 61000-6-3 e SS-EN 61000-6-2, fabricado conforme DIN 6653-2, sistema testado pelo TÜV-Rheinland e certificado pela UL\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eCompatibilidade e casos de utilização\u003c\/h2\u003e\n      \u003cp\u003eEsta unidade central foi concebida para trabalhar com sensores fixos LogiCO2 e centralizar a informação de segurança em instalações onde se utiliza CO2. É especialmente útil em hotelaria, câmaras, adegas, cervejarias, salas técnicas, produtores de bebidas e outros espaços interiores com distribuição ou armazenamento de CO2.\u003c\/p\u003e\n      \u003cp\u003eA sua lógica de utilização faz sentido quando existe mais de um ponto de vigilância, quando se pretende identificar de que sensor chega um alarme ou quando se procura uma supervisão mais clara de todo o sistema.\u003c\/p\u003e\n      \u003cp\u003ePara funcionar, necessita de sensores compatíveis dentro do ecossistema LogiCO2 e de uma arquitetura de cablagem adequada. A própria página oficial do produto indica compatibilidade com sensores fixos LogiCO2 e também com sensores MkVII antigos.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eInstalação e considerações antes de comprar\u003c\/h2\u003e\n      \u003cul class=\"iblgmk9-bullets\"\u003e\n        \u003cli\u003eVerifique primeiro quantos sensores o sistema irá realmente gerir, porque a ficha 0328 e a documentação geral não coincidem na capacidade máxima declarada.\u003c\/li\u003e\n        \u003cli\u003eVerifique se a instalação dispõe de sensores LogiCO2 compatíveis e da topologia de cablagem adequada.\u003c\/li\u003e\n        \u003cli\u003eAvalie a localização da unidade central numa zona visível, acessível e protegida para consulta, silenciamento, teste e reinício.\u003c\/li\u003e\n        \u003cli\u003eConfirme a alimentação disponível: a unidade trabalha a 12-24 V CC.\u003c\/li\u003e\n        \u003cli\u003eSe o sistema tiver de mostrar vários sensores, certifique-se de configurar corretamente o número de sensores ligados, de acordo com o manual.\u003c\/li\u003e\n        \u003cli\u003ePlaneje também a sinalização de alarme, sinaleiros ou sirenes associados a todo o sistema, não apenas à unidade central.\u003c\/li\u003e\n        \u003cli\u003ePor se tratar de um elemento de segurança, a instalação e a colocação em serviço devem ser feitas com critério técnico e verificação funcional do sistema.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eManutenção e utilização recomendada\u003c\/h2\u003e\n      \u003cp\u003eA unidade central não substitui a manutenção do sistema: é conveniente verificar periodicamente o estado dos cabos, conectores, leds, avisador acústico e ecrã, além de confirmar que a central recebe e mostra corretamente a informação de cada sensor ligado.\u003c\/p\u003e\n      \u003cp\u003eO manual recomenda testar o alarme para garantir que a comunicação, as luzes de aviso e os indicadores acústicos funcionam corretamente. Em caso de alarme, o avisador acústico pode ser silenciado brevemente e o reinício completo deve ser feito quando a ocorrência tiver sido resolvida.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-faq\"\u003e\n      \u003ch2\u003ePerguntas frequentes\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eO que faz exatamente esta unidade central Mk9?\u003c\/summary\u003e\n        \u003cp\u003eCentraliza as informações do sistema de segurança de CO2, mostra leituras e alarmes dos sensores, controla o funcionamento do sistema e permite silenciar ou reiniciar o alarme.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eInclui sensores de CO2?\u003c\/summary\u003e\n        \u003cp\u003eNão. Este kit corresponde à unidade central e aos seus acessórios básicos de ligação e sinalização. Os sensores são fornecidos em separado.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eQuantos sensores pode supervisionar?\u003c\/summary\u003e\n        \u003cp\u003eA ficha do artigo 0328 indica até 8 sensores. A documentação geral Mk9\/Mk90 mostra configurações de até 12 sensores. Em ampliações, é conveniente confirmar a configuração exata do sistema antes de comprar.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eO que inclui o kit 0328?\u003c\/summary\u003e\n        \u003cp\u003eInclui a unidade central Mk9, um cabo vermelho RJ45 de 5 metros, um divisor RJ45 1-2, o letreiro do sistema de segurança de CO2 Mk9 e a documentação correspondente.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eÉ possível silenciar um alarme a partir da unidade central?\u003c\/summary\u003e\n        \u003cp\u003eSim. A unidade dispõe de botão frontal de silenciamento e reinício. Também permite testar o sistema a partir do próprio equipamento.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCom que sensores é compatível?\u003c\/summary\u003e\n        \u003cp\u003eÉ destinada a sensores fixos LogiCO2. A página oficial do produto também indica compatibilidade com sensores MkVII antigos.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-downloads\"\u003e\n      \u003ch2\u003eTransferíveis\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-download-grid\"\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/KIT_adicional_de_unidad_central_de_CO2.pdf?v=1775035270\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eFicha técnica LogiCO2 0328\u003c\/a\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManual Mk9 \/ Mk90\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-related\"\u003e\n      \u003ch2\u003eTambém pode interessar‑lhe\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-related-grid\"\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"\/pt-eea\/collections\/alarmas-detectores-co2-logico2\"\u003eAlarmas y detectores de CO2 LogiCO2\u003c\/a\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"\/pt-eea\/pages\/servicio-tecnico\"\u003eAconselhamento e instalação técnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57238885597532,"sku":"LG005","price":228.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/mk9-central-unit-cab-logico2.webp?v=1775036817","url":"https:\/\/installbeer.com\/pt-eea\/products\/kit-4a-unidade-central-co2-logico2-mk9","provider":"Install Beer","version":"1.0","type":"link"}