{"product_id":"conjunto-detector-o2-logico2-mk9-central-alarma","title":"Conjunto de sensores de O2 LogiCO2 Mk9 com central e alarme","description":"\u003csection class=\"iblgo2-product iblgo2-2057\" data-brand=\"LogiCO2\" data-model=\"O2 Mk9 Detector Base SET\"\u003e\n  \u003cstyle\u003e\n    .iblgo2-product{\n      --ib-max:1120px;\n      --ib-text:#1f2328;\n      --ib-muted:#5b6573;\n      --ib-line:#e6e8eb;\n      --ib-soft:#f7f8fa;\n      --ib-soft2:#f2f4f6;\n      --ib-accent:#111111;\n      --ib-radius:18px;\n      --ib-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ib-content-size:16px;\n      --ib-content-lh:1.68;\n      --ib-h2-size:28px;\n      --ib-h3-size:20px;\n      color:var(--ib-text);\n      font-size:var(--ib-content-size);\n      line-height:var(--ib-content-lh);\n    }\n    .iblgo2-product *{box-sizing:border-box}\n    .iblgo2-wrap{max-width:var(--ib-max);margin:0 auto;padding:4px 0 36px}\n    .iblgo2-hero,.iblgo2-block,.iblgo2-specs,.iblgo2-faq,.iblgo2-downloads,.iblgo2-related{\n      background:#fff;border:1px solid var(--ib-line);border-radius:var(--ib-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ib-shadow)\n    }\n    .iblgo2-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ib-line);\n      border-radius:999px;background:var(--ib-soft);color:var(--ib-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblgo2-product h2{\n      font-size:var(--ib-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ib-accent)\n    }\n    .iblgo2-product h3{\n      font-size:var(--ib-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ib-accent)\n    }\n    .iblgo2-product p{margin:0 0 14px;font-size:var(--ib-content-size);line-height:var(--ib-content-lh)}\n    .iblgo2-product p:last-child{margin-bottom:0}\n    .iblgo2-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ib-soft);border:1px solid var(--ib-line)\n    }\n    .iblgo2-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblgo2-card{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:var(--ib-soft)\n    }\n    .iblgo2-card strong{display:block;margin-bottom:6px;color:var(--ib-accent)}\n    .iblgo2-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ib-accent);\n      background:var(--ib-soft2);border-radius:12px\n    }\n    .iblgo2-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblgo2-list-grid li{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:#fff\n    }\n    .iblgo2-list-grid li strong{display:block;margin-bottom:6px}\n    .iblgo2-bullets{margin:0;padding-left:18px}\n    .iblgo2-bullets li{margin:0 0 10px}\n    .iblgo2-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblgo2-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ib-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblgo2-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ib-accent)\n    }\n    .iblgo2-table thead th{\n      background:var(--ib-soft2);color:var(--ib-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);font-size:15px\n    }\n    .iblgo2-table tbody th,.iblgo2-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblgo2-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ib-accent)}\n    .iblgo2-table tbody tr:last-child th,.iblgo2-table tbody tr:last-child td{border-bottom:none}\n    .iblgo2-download-grid,.iblgo2-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblgo2-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ib-accent);text-decoration:none;color:var(--ib-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblgo2-btn:hover{transform:translateY(-1px);box-shadow:var(--ib-shadow)}\n    .iblgo2-faq details{\n      border:1px solid var(--ib-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblgo2-faq details:last-child{margin-bottom:0}\n    .iblgo2-faq summary{cursor:pointer;font-weight:700;color:var(--ib-accent)}\n    .iblgo2-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblgo2-cards,.iblgo2-list-grid,.iblgo2-download-grid,.iblgo2-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblgo2-product{\n        --ib-content-size:15px;\n        --ib-h2-size:23px;\n        --ib-h3-size:18px;\n      }\n      .iblgo2-hero,.iblgo2-block,.iblgo2-specs,.iblgo2-faq,.iblgo2-downloads,.iblgo2-related{\n        padding:18px;border-radius:16px\n      }\n      .iblgo2-table{min-width:100%;border:0}\n      .iblgo2-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblgo2-table,.iblgo2-table tbody,.iblgo2-table tr,.iblgo2-table th,.iblgo2-table td{\n        display:block;width:100%\n      }\n      .iblgo2-table tr{\n        border:1px solid var(--ib-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblgo2-table tbody th{\n        background:var(--ib-soft2);border-bottom:1px solid var(--ib-line)\n      }\n      .iblgo2-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblgo2-wrap\"\u003e\n    \u003cdiv class=\"iblgo2-hero\"\u003e\n      \u003cdiv class=\"iblgo2-kicker\"\u003eSegurança O2 · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eDetetor de O2 LogiCO2 Mk9 para vigiar níveis inseguros de oxigênio\u003c\/h2\u003e\n      \u003cp class=\"iblgo2-snippet\"\u003e\u003cstrong\u003eO conjunto detetor de O2 LogiCO2 Mk9 integra sensor ótico, unidade central e sirene\/sinaleiro para detectar níveis inseguros de oxigênio em espaços fechados com nitrogênio ou outros gases asfixiantes e avisar de forma visual e acústica.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eO que este produto oferece\u003c\/h2\u003e\n      \u003cp\u003eEste sistema foi concebido para monitorar zonas onde o nível de oxigênio pode descer abaixo de um limite seguro. É especialmente indicado para salas técnicas, câmaras, recintos com nitrogênio, geradores de nitrogênio, depósitos de nitrogênio e zonas com gás misturado com nitrogênio.\u003c\/p\u003e\n      \u003cp\u003eEm comparação com equipamentos isolados, este conjunto já reúne sensor de O2 Mk9, unidade central Mk9, sirene\/baliza estroboscópica, fonte de alimentação, conectores, cablagem e sinalização. Isto facilita uma implementação inicial mais organizada e uma supervisão centralizada do sistema.\u003c\/p\u003e\n      \u003cp\u003eO sensor utiliza detecção óptica, incorpora compensação de temperatura e pressão, conta com autocalibração automática e mostra a concentração atual de O2 e as horas de funcionamento em sua tela retroiluminada.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eDados-chave\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-cards\"\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eReferência do fabricante\u003c\/strong\u003e\n          2057\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG008\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eConfiguração base\u003c\/strong\u003e\n          1 sensor + 1 unidade central + 1 sirene\/baliza\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eAlarme por defeito\u003c\/strong\u003e\n          \u003c19,5 % O2\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eComunicação\u003c\/strong\u003e\n          RS485 Modbus\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eAmpliação do sistema\u003c\/strong\u003e\n          Até 8 sensores\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblgo2-note\"\u003e\n        \u003cstrong\u003eImportante:\u003c\/strong\u003e este produto não serve para detectar CO2. Ele foi projetado para monitorar níveis de oxigênio em espaços fechados com risco de atmosfera deficiente em O2, especialmente onde há nitrogênio ou gases asfixiantes.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eCaracterísticas principais\u003c\/h2\u003e\n      \u003cul class=\"iblgo2-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSistema completo de segurança O2\u003c\/strong\u003e Inclui sensor, central, sirene\/baliza, fonte de alimentação, conectores, sinalética e manual.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSensor ótico de longa vida útil\u003c\/strong\u003e A LogiCO2 evita as células eletroquímicas tradicionais e utiliza detecção ótica com autocalibração.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSupervisão centralizada\u003c\/strong\u003e A unidade central mostra valores de O2, alarmes e o sensor que origina a ocorrência.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAlarme visual e acústico\u003c\/strong\u003e A central e a sirene\/baliza avisam quando são atingidos níveis inseguros de oxigênio.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAté 8 sensores\u003c\/strong\u003e O sistema pode ser ampliado com sensores O2 Mk9 e também admite sensores CO2 Mk9 ou Mk90 conforme o manual.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompensação de altitude\u003c\/strong\u003e O sensor dispõe de compensação de altitude.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eInstalação à altura de respiração\u003c\/strong\u003e Concebido para ser montado entre 150 e 180 cm do chão.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUtilização interior profissional\u003c\/strong\u003e Orientado para espaços fechados onde um défice de O2 pode comprometer a segurança.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-specs\"\u003e\n      \u003ch2\u003eEspecificações técnicas\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-table-wrap\"\u003e\n        \u003ctable class=\"iblgo2-table\"\u003e\n          \u003ccaption\u003eEspecificações técnicas confirmadas do conjunto detetor de O2 LogiCO2 Mk9\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParâmetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDado confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarca\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModelo\u003c\/th\u003e\n              \u003ctd\u003eO2 Mk9 Detector Base SET\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG008\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ referência do fabricante\u003c\/th\u003e\n              \u003ctd\u003e2057\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTipo de equipamento\u003c\/th\u003e\n              \u003ctd\u003eSistema de segurança de O2 com sensor remoto, unidade central e sirene\/baliza estroboscópica\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConfiguração do conjunto\u003c\/th\u003e\n              \u003ctd\u003eSensor de O2 Mk9 + Unidade central Mk9 + Sirene\/Baliza LED âmbar + transformador + cablagem + sinalização\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eNúmero de sensores\u003c\/th\u003e\n              \u003ctd\u003e1–8\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFonte de alimentação do sistema\u003c\/th\u003e\n              \u003ctd\u003e12-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAlimentação do sensor\u003c\/th\u003e\n              \u003ctd\u003e24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConsumo do sensor\u003c\/th\u003e\n              \u003ctd\u003e\u003c30 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003econexões de cablagem\u003c\/th\u003e\n              \u003ctd\u003eRJ45\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eInterface digital\u003c\/th\u003e\n              \u003ctd\u003ePorta série RS485 Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSaídas do sensor\u003c\/th\u003e\n              \u003ctd\u003e2 saídas de transistor de 24 V CC, mín. 1 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTela do sensor\u003c\/th\u003e\n              \u003ctd\u003eGráfico 128x64, retroiluminado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTela da unidade central\u003c\/th\u003e\n              \u003ctd\u003eGráfico 128x64, retroiluminado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSinal acústico do sensor\u003c\/th\u003e\n              \u003ctd\u003e76 dBa (1 m) máx.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSinal acústico da unidade central\u003c\/th\u003e\n              \u003ctd\u003eO manual descreve aviso acústico interno; intensidade não indicada na ficha de produto\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePrincípio de funcionamento\u003c\/th\u003e\n              \u003ctd\u003eFB-ótico\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGama de medição de O2\u003c\/th\u003e\n              \u003ctd\u003e0-100 % vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePrecisão de O2\u003c\/th\u003e\n              \u003ctd\u003e\u003c2 % FE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAlarme por defeito\u003c\/th\u003e\n              \u003ctd\u003e\u003c19,5 % O2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAjuste adicional\u003c\/th\u003e\n              \u003ctd\u003eCompensação de altitude\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura ambiente do sensor\u003c\/th\u003e\n              \u003ctd\u003eDe -20 a +40 °C. Apenas para uso em interiores.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensões do sensor\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProteção do sensor\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTensão nominal da sirene\/baliza\u003c\/th\u003e\n              \u003ctd\u003e18-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirene\/sinaleiro corrente média\u003c\/th\u003e\n              \u003ctd\u003e120 mA a 24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDecibéis da sirene\/baliza\u003c\/th\u003e\n              \u003ctd\u003e110 dB \/ 1 m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIntensidade do flash da sirene\/baliza\u003c\/th\u003e\n              \u003ctd\u003e115 cd\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFrequência do flash da sirene\/baliza\u003c\/th\u003e\n              \u003ctd\u003e65\/min\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirene\/sinaleiro temperatura ambiente\u003c\/th\u003e\n              \u003ctd\u003eDe -5 a +50 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensões da sirene\/baliza\u003c\/th\u003e\n              \u003ctd\u003e134 x 115 x 61 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirene\/baliza de proteção\u003c\/th\u003e\n              \u003ctd\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCapacidade da unidade central\u003c\/th\u003e\n              \u003ctd\u003eAté 8 sensores; mostra valores de O₂ e o sensor que origina o alarme\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIndicadores da central\u003c\/th\u003e\n              \u003ctd\u003eLED verde funcionamento, LED vermelho alarme, LED amarelo falha, botão de silêncio\/reinício\/teste\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConteúdo do fornecimento\u003c\/th\u003e\n              \u003ctd\u003eUnidade central Mk9, cabo vermelho 5 m, sensor de O2 Mk9, cabo vermelho 10 m, cabo azul 5 m, sirene\/sinaleiro estroboscópico com LED âmbar e cabo de 1 m, divisor RJ45 1-1, divisor RJ45 1-2, transformador de 1 A, fichas UL\/CE\/AU\/R.U., bloqueio de ficha, saco com 6 parafusos e bucha, letreiro do sistema de segurança de O2 Mk9, letreiro de sirene\/sinaleiro estroboscópico Mk9 e manual de instalação O2 Mk9\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGTIN\/EAN\u003c\/th\u003e\n              \u003ctd\u003eDado não fornecido\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCódigo SA\/HS\u003c\/th\u003e\n              \u003ctd\u003eDado não fornecido\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePeso\u003c\/th\u003e\n              \u003ctd\u003eDado não fornecido\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eCompatibilidade e casos de utilização\u003c\/h2\u003e\n      \u003cp\u003eEste sistema é utilizado em espaços fechados onde existe risco de concentração insegura de oxigênio. O próprio manual posiciona o sensor em pontos de distribuição de nitrogênio, geradores de nitrogênio, tanques de nitrogênio e áreas com gás misturado com nitrogênio.\u003c\/p\u003e\n      \u003cp\u003eTambém pode ser utilizado quando o gás asfixiante é armazenado fora do edifício, mas entra no interior através de tubulações, desde que a área monitorada seja aquela em que realmente existe risco para as pessoas.\u003c\/p\u003e\n      \u003cp\u003eO sistema pode ser ampliado com até oito sensores de O2 Mk9 e, de acordo com o manual, a unidade central também pode trabalhar com sensores de CO2 Mk9 e Mk90 dentro da arquitetura LogiCO2.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eInstalação e considerações antes de comprar\u003c\/h2\u003e\n      \u003cul class=\"iblgo2-bullets\"\u003e\n        \u003cli\u003eO sensor de O2 deve ser montado à altura da respiração, entre 150 e 180 cm do chão.\u003c\/li\u003e\n        \u003cli\u003eA sirene\/baliza deve ser instalada acima do sensor, a aproximadamente 2–2,4 m do piso e visível a partir de qualquer entrada da área vigiada.\u003c\/li\u003e\n        \u003cli\u003eRecomenda-se instalar uma segunda sirene\/baliza fora da zona vigiada, de preferência acima da porta ou portas de acesso.\u003c\/li\u003e\n        \u003cli\u003eA unidade central deve ser instalada fora da zona ou sala vigiada, numa posição visível e acessível.\u003c\/li\u003e\n        \u003cli\u003eSe a sala tiver apenas ventilação mecânica, o manual indica que deve ter sensor.\u003c\/li\u003e\n        \u003cli\u003eSe for utilizado um gerador de nitrogênio na mesma zona, o excesso de oxigênio gerado deve ser conduzido para o exterior; o manual indica que não é permitido utilizar o sensor na zona se esse oxigênio não for extraído.\u003c\/li\u003e\n        \u003cli\u003eO sistema não funciona se estiver desconectado da rede elétrica, portanto a alimentação e seu bloqueio mecânico devem ser verificados antes da partida.\u003c\/li\u003e\n        \u003cli\u003eSendo um equipamento de segurança, a instalação e a manutenção devem ser realizadas apenas por profissionais.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eManutenção e utilização recomendada\u003c\/h2\u003e\n      \u003cp\u003eO sensor de O2 LogiCO2 incorpora autocalibração automática ativada de série e não deverá requerer calibração manual em condições normais, desde que permaneça ligado de forma contínua. No entanto, o próprio fabricante indica que é necessária uma calibração manual no momento da colocação em serviço.\u003c\/p\u003e\n      \u003cp\u003eAlém disso, por se tratar de um produto de segurança, recomenda-se realizar um controle de funcionamento pelo menos uma vez por ano. A limpeza deve ser feita com água e um pano umedecido, e o sensor e a carcaça da unidade central não devem ser abertos por pessoal não autorizado.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-faq\"\u003e\n      \u003ch2\u003ePerguntas frequentes\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eEste sistema deteta CO2?\u003c\/summary\u003e\n        \u003cp\u003eNão. Este produto foi concebido para detectar níveis inseguros de oxigênio em espaços fechados.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eO que inclui exatamente o conjunto 2057?\u003c\/summary\u003e\n        \u003cp\u003eInclui sensor de O2 Mk9, unidade central Mk9, sirene\/baliza estroboscópica, transformador, cablagem, conectores RJ45, sinalização e manual de instalação.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eOnde deve ser instalado o sensor de O2?\u003c\/summary\u003e\n        \u003cp\u003eDeve ser instalado à altura da respiração, entre 150 e 180 cm do piso, na área onde realmente exista risco de atmosfera insegura.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eOnde se instala a sirene\/baliza e a unidade central?\u003c\/summary\u003e\n        \u003cp\u003eA sirene\/baliza deve ser colocada sobre o sensor, a cerca de 2-2,4 m do chão. A unidade central deve ser montada fora da zona vigiada, num ponto claramente visível e acessível.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eQual é o nível de alarme predefinido?\u003c\/summary\u003e\n        \u003cp\u003eO fabricante indica um nível de alarme por defeito de 19,5 % de O2.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eNecessita de manutenção periódica?\u003c\/summary\u003e\n        \u003cp\u003eSim. Embora disponha de autocalibração automática, recomenda-se uma verificação funcional pelo menos uma vez por ano e uma calibração manual inicial ao ligar o sistema.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-downloads\"\u003e\n      \u003ch2\u003eTransferíveis\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-download-grid\"\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/O2_Mk9_Detector_BaseSET_2057_es_db_LogiCO2.pdf?v=1775037461\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eFicha técnica LogiCO2 2057\u003c\/a\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/o2ss_mk9_2057_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManual O2 Mk9\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-related\"\u003e\n      \u003ch2\u003eTambém pode interessar‑lhe\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-related-grid\"\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"\/pt-br\/collections\/logico2-detetores-co2-seguranca-industrial-horeca-1\"\u003eAlarmes e detetores LogiCO2\u003c\/a\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"\/pt-br\/pages\/servicio-tecnico\"\u003eassessoria e instalação técnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57238900572508,"sku":"LG008","price":6283.03,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/o2-mk9detector-set-logic2.webp?v=1775037730","url":"https:\/\/installbeer.com\/pt-br\/products\/conjunto-de-sensores-de-o2-logico2-mk9-com-central-e-alarme","provider":"Install Beer","version":"1.0","type":"link"}