{"product_id":"kit-sensor-de-co2-logico2-mk90","title":"Extra CO2‑sensorkit LogiCO2 Mk90","description":"\u003csection class=\"ibmk90-product ibmk90-1190\" data-brand=\"LogiCO2\" data-model=\"CO2 Sensor Mk90\"\u003e\n  \u003cstyle\u003e\n    .ibmk90-product{\n      --ibmk90-max:1120px;\n      --ibmk90-text:#1f2328;\n      --ibmk90-muted:#5b6573;\n      --ibmk90-line:#e6e8eb;\n      --ibmk90-soft:#f7f8fa;\n      --ibmk90-soft2:#f2f4f6;\n      --ibmk90-accent:#111111;\n      --ibmk90-radius:18px;\n      --ibmk90-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibmk90-content-size:16px;\n      --ibmk90-content-lh:1.68;\n      --ibmk90-h2-size:28px;\n      --ibmk90-h3-size:20px;\n      color:var(--ibmk90-text);\n      font-size:var(--ibmk90-content-size);\n      line-height:var(--ibmk90-content-lh);\n    }\n    .ibmk90-product *{box-sizing:border-box}\n    .ibmk90-wrap{max-width:var(--ibmk90-max);margin:0 auto;padding:4px 0 36px}\n    .ibmk90-hero,.ibmk90-block,.ibmk90-specs,.ibmk90-faq,.ibmk90-downloads,.ibmk90-related{\n      background:#fff;border:1px solid var(--ibmk90-line);border-radius:var(--ibmk90-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibmk90-shadow)\n    }\n    .ibmk90-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibmk90-line);\n      border-radius:999px;background:var(--ibmk90-soft);color:var(--ibmk90-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibmk90-product h2{\n      font-size:var(--ibmk90-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibmk90-accent)\n    }\n    .ibmk90-product h3{\n      font-size:var(--ibmk90-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibmk90-accent)\n    }\n    .ibmk90-product p{\n      margin:0 0 14px;\n      font-size:var(--ibmk90-content-size);\n      line-height:var(--ibmk90-content-lh)\n    }\n    .ibmk90-product p:last-child{margin-bottom:0}\n    .ibmk90-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibmk90-soft);border:1px solid var(--ibmk90-line)\n    }\n    .ibmk90-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibmk90-card{\n      padding:16px;border:1px solid var(--ibmk90-line);border-radius:16px;background:var(--ibmk90-soft)\n    }\n    .ibmk90-card strong{display:block;margin-bottom:6px;color:var(--ibmk90-accent)}\n    .ibmk90-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibmk90-accent);\n      background:var(--ibmk90-soft2);border-radius:12px\n    }\n    .ibmk90-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibmk90-list-grid li{\n      padding:16px;border:1px solid var(--ibmk90-line);border-radius:16px;background:#fff\n    }\n    .ibmk90-list-grid li strong{display:block;margin-bottom:6px}\n    .ibmk90-bullets{margin:0;padding-left:18px}\n    .ibmk90-bullets li{margin:0 0 10px}\n    .ibmk90-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibmk90-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibmk90-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibmk90-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibmk90-accent)\n    }\n    .ibmk90-table thead th{\n      background:var(--ibmk90-soft2);color:var(--ibmk90-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibmk90-line);font-size:15px\n    }\n    .ibmk90-table tbody th,.ibmk90-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibmk90-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibmk90-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibmk90-accent)}\n    .ibmk90-table tbody tr:last-child th,.ibmk90-table tbody tr:last-child td{border-bottom:none}\n    .ibmk90-download-grid,.ibmk90-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibmk90-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibmk90-accent);text-decoration:none;color:var(--ibmk90-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibmk90-btn:hover{transform:translateY(-1px);box-shadow:var(--ibmk90-shadow)}\n    .ibmk90-faq details{\n      border:1px solid var(--ibmk90-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibmk90-faq details:last-child{margin-bottom:0}\n    .ibmk90-faq summary{cursor:pointer;font-weight:700;color:var(--ibmk90-accent)}\n    .ibmk90-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibmk90-cards,.ibmk90-list-grid,.ibmk90-download-grid,.ibmk90-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibmk90-product{\n        --ibmk90-content-size:15px;\n        --ibmk90-h2-size:23px;\n        --ibmk90-h3-size:18px;\n      }\n      .ibmk90-hero,.ibmk90-block,.ibmk90-specs,.ibmk90-faq,.ibmk90-downloads,.ibmk90-related{\n        padding:18px;border-radius:16px\n      }\n      .ibmk90-table{min-width:100%;border:0}\n      .ibmk90-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibmk90-table,.ibmk90-table tbody,.ibmk90-table tr,.ibmk90-table th,.ibmk90-table td{\n        display:block;width:100%\n      }\n      .ibmk90-table tr{\n        border:1px solid var(--ibmk90-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibmk90-table tbody th{\n        background:var(--ibmk90-soft2);border-bottom:1px solid var(--ibmk90-line)\n      }\n      .ibmk90-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibmk90-wrap\"\u003e\n    \u003cdiv class=\"ibmk90-hero\"\u003e\n      \u003cdiv class=\"ibmk90-kicker\"\u003eCO2‑sensor · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 Mk90 CO2-sensor om een detectiepunt uit te breiden of te vervangen\u003c\/h2\u003e\n      \u003cp class=\"ibmk90-snippet\"\u003e\u003cstrong\u003eDe LogiCO2 Mk90 CO2-sensor is een detectiemodule met geïntegreerd akoestisch en visueel alarm die de CO2-concentratie in besloten ruimten meet en wordt aangesloten op de Mk9-centrale binnen het LogiCO2-beveiligingssysteem.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eWat biedt dit product\u003c\/h2\u003e\n      \u003cp\u003eDit product is bedoeld om een bestaande installatie uit te breiden of een Mk90-sensor binnen een LogiCO2-systeem te vervangen. Het is geen complete kit met centrale, sirene\/zwaailicht en voeding, maar de sensormodule.\u003c\/p\u003e\n      \u003cp\u003eHet belangrijkste voordeel ten opzichte van een basissensor is de Mk90‑constructie zelf: translucente behuizing, rode high‑intensity alarmleds, lokale akoestische indicatie en lcd‑display met uitlezing van CO2, TWA en temperatuur wanneer het thermische alarm is geactiveerd.\u003c\/p\u003e\n      \u003cp\u003eBij Install Beer, als officiële distributeur in Europa en technische dienst voor montage en onderhoud, past dit type module vooral bij uitbreidingen, vervangingen en onderhoud van reeds geïnstalleerde LogiCO2‑systemen.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eBelangrijke gegevens\u003c\/h2\u003e\n      \u003cdiv class=\"ibmk90-cards\"\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eFabrikantartikel\u003c\/strong\u003e\n          1190\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG015\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eType\u003c\/strong\u003e\n          CO2-sensor voor Mk9-systeem\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eMeetbereik\u003c\/strong\u003e\n          0–3 vol.%.\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eWeergave op het scherm\u003c\/strong\u003e\n          Tot 6,7 % vol.\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eBescherming\u003c\/strong\u003e\n          IP54\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"ibmk90-note\"\u003e\n        \u003cstrong\u003eBelangrijk:\u003c\/strong\u003e op de officiële pagina staat dat het pakket de Mk90‑sensor bevat. Controleer vóór aankoop of je bij jouw vervanging of uitbreiding daarnaast bekabeling, centrale, sirene\/baken of andere systeemaccessoires nodig hebt.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eBelangrijkste kenmerken\u003c\/h2\u003e\n      \u003cul class=\"ibmk90-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eGeïntegreerd alarm\u003c\/strong\u003e De sensor heeft een akoestische en optische indicatie en is dus niet uitsluitend afhankelijk van de centrale.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eRode high‑intensity leds\u003c\/strong\u003e De Mk90 voegt een versterkte visuele waarschuwing toe dankzij de translucente behuizing en goed zichtbare alarmleds.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLCD-scherm\u003c\/strong\u003e Toont de actuele CO2-concentratie, TWA en temperatuur als de temperatuurfunctie is geactiveerd.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eNDIR-detectie\u003c\/strong\u003e Gebruikt niet-dispersief infrarood en een thermistor om CO2 te meten.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eProfessionele communicatie\u003c\/strong\u003e Wordt via RS485 Modbus in het LogiCO2-systeem geïntegreerd.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eConfigureerbaar adres\u003c\/strong\u003e De handleiding voorziet in ID-instelling van 1 tot 12 via DIP-schakelaars.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAutomatische autocalibratie\u003c\/strong\u003e Vermindert de jaarlijkse nulpuntdrift en helpt de meetstabiliteit te behouden.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLange levensduur\u003c\/strong\u003e Volgens de handleiding heeft de sensor een levensduur van meer dan 15 jaar.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-specs\"\u003e\n      \u003ch2\u003eTechnische specificaties\u003c\/h2\u003e\n      \u003cdiv class=\"ibmk90-table-wrap\"\u003e\n        \u003ctable class=\"ibmk90-table\"\u003e\n          \u003ccaption\u003eBevestigde technische specificaties van de LogiCO2 Mk90 CO2‑sensor\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eBevestigde gegevens\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMerk\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eCO2 Sensor Mk90\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG015\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artikel fabrikant\u003c\/th\u003e\n              \u003ctd\u003e1190\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eType apparaat\u003c\/th\u003e\n              \u003ctd\u003eCO2‑sensor voor LogiCO2‑veiligheidssysteem\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCompatibiliteit\u003c\/th\u003e\n              \u003ctd\u003eAansluitbaar op Mk9 Central Unit en Mk9 CO2 Sensor Set\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFuente de alimentación\u003c\/th\u003e\n              \u003ctd\u003e24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eVerbruik zonder alarm\u003c\/th\u003e\n              \u003ctd\u003e56 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eVerbruik in alarmtoestand\u003c\/th\u003e\n              \u003ctd\u003e117 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBekabelingsaansluitingen\u003c\/th\u003e\n              \u003ctd\u003eRJ45\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDigitale interface\u003c\/th\u003e\n              \u003ctd\u003eSeriële RS485‑Modbuspoort\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUitgangen\u003c\/th\u003e\n              \u003ctd\u003e2 transistoruitgangen van 24 V DC, min. 1 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n              \u003ctd\u003eLCD\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGeluidsniveau akoestisch signaal\u003c\/th\u003e\n              \u003ctd\u003e80 dBa (1 m) max.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWerkingsprincipe\u003c\/th\u003e\n              \u003ctd\u003eNiet‑dispersief infrarood (NDIR) en thermistor\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMeetbereik CO2\u003c\/th\u003e\n              \u003ctd\u003e0–3 vol.%.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeergave op het scherm\u003c\/th\u003e\n              \u003ctd\u003eHuidige CO2-concentratie van 0,0 % tot 6,7 %, TWA en temperatuur indien de thermische alarmfunctie is geactiveerd\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eNauwkeurigheid\u003c\/th\u003e\n              \u003ctd\u003e±200 ppm ±10 % van de uitlezing\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eResolutie\u003c\/th\u003e\n              \u003ctd\u003e0,01 % vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eJaarlijkse nulpuntafwijking\u003c\/th\u003e\n              \u003ctd\u003e\u003c0,01 % vol. met automatische autokalibratiefunctie\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBedrijfstemperatuur\u003c\/th\u003e\n              \u003ctd\u003e0 tot +45 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBedrijfsvochtigheid\u003c\/th\u003e\n              \u003ctd\u003e0 tot 95 % RV zonder condensatie\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOpwarmtijd\u003c\/th\u003e\n              \u003ctd\u003e1 minuut bij 22 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLevensduur van de sensor\u003c\/th\u003e\n              \u003ctd\u003e\u003e15 años\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAfmetingen\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBescherming tegen binnendringen\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOverspanning\u003c\/th\u003e\n              \u003ctd\u003eCategorie II\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eVervuilingsgraad\u003c\/th\u003e\n              \u003ctd\u003eII\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eStandaardniveaus\u003c\/th\u003e\n              \u003ctd\u003eBewustwording \u003e5000 ppm, laag alarm 1,5 %, hoog alarm 3 %, TWA 5000 ppm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLeveringsomvang\u003c\/th\u003e\n              \u003ctd\u003eCO2 Sensor Mk90\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGewicht\u003c\/th\u003e\n              \u003ctd\u003e1 Kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eCompatibiliteit en toepassingsgebieden\u003c\/h2\u003e\n      \u003cp\u003eDeze sensor is bedoeld om te worden geïntegreerd in het LogiCO2‑beveiligingssysteem met Mk9‑centrale en sensorconfiguraties per ID. Hij is geschikt als reserveonderdeel of uitbreiding wanneer er al een werkende CO2‑beveiligingsinstallatie aanwezig is.\u003c\/p\u003e\n      \u003cp\u003eGeschikt voor horeca, wijnkelders, brouwerijen, koelcellen, technische ruimten en andere besloten ruimtes waar CO2 wordt gebruikt of opgeslagen en waar een extra detectiepunt of vervanging van een bestaande sensor nodig is.\u003c\/p\u003e\n      \u003cp\u003eHet is ook een nuttige optie wanneer men dezelfde LogiCO2-architectuur en dezelfde lokale meldingslogica in de sensor zelf wil behouden.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eInstallatie en aandachtspunten vóór aankoop\u003c\/h2\u003e\n      \u003cul class=\"ibmk90-bullets\"\u003e\n        \u003cli\u003eDe handleiding geeft aan dat de sensor op een maximale hoogte van 30 cm boven de vloer moet worden geïnstalleerd.\u003c\/li\u003e\n        \u003cli\u003eHij moet op maximaal 5 m afstand van het distributiepunt of de mogelijke CO2-lekbron worden geplaatst.\u003c\/li\u003e\n        \u003cli\u003eElke sensor dekt een maximale oppervlakte van 78 m² in een gesloten ruimte.\u003c\/li\u003e\n        \u003cli\u003eMonteer de sensor bij voorkeur op een plek met zo weinig mogelijk risico op stoten door bewegende objecten, dozen of schoonmaakmateriaal.\u003c\/li\u003e\n        \u003cli\u003eAls het systeem een sirene\/baken omvat, moet dit boven op de sensor worden gemonteerd, op ongeveer 2‑2,4 m boven de vloer en duidelijk zichtbaar vanaf de ingang.\u003c\/li\u003e\n        \u003cli\u003eControleer vóór aankoop of je alleen de sensor nodig hebt of een complete set met centrale, baken en voeding.\u003c\/li\u003e\n        \u003cli\u003eOmdat het een veiligheidscomponent is, moeten installatie en functionele controle met technisch inzicht worden uitgevoerd.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eAanbevolen onderhoud en gebruik\u003c\/h2\u003e\n      \u003cp\u003eIn de handleiding wordt aanbevolen om minstens één keer per jaar een functionele controle uit te voeren, juist omdat het om een veiligheidsproduct gaat.\u003c\/p\u003e\n      \u003cp\u003eIn werkelijk gebruik is het raadzaam de weergegeven waarde, de werking van de leds, het akoestische signaal en de correcte integratie met de rest van het systeem regelmatig te controleren, vooral na vervanging van de sensor of wijziging van het ID‑adres.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-faq\"\u003e\n      \u003ch2\u003eVeelgestelde vragen\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIs dit product een complete CO2‑alarmkit?\u003c\/summary\u003e\n        \u003cp\u003eNee. Het gaat om de Mk90-sensor, bedoeld om te worden geïntegreerd in een LogiCO2-systeem met Mk9-centrale of als vervangingsonderdeel binnen een bestaande installatie.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eMet welk systeem is hij compatibel?\u003c\/summary\u003e\n        \u003cp\u003eOp de officiële pagina staat compatibiliteit met de Mk9‑centrale en met de Mk9 CO2 Sensor Set vermeld.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWat meet hij precies?\u003c\/summary\u003e\n        \u003cp\u003eMeet de CO2‑concentratie en toont op het display de actuele concentratie, TWA en temperatuur wanneer het thermische alarm is geactiveerd.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWelke alarmniveaus zijn standaard ingesteld?\u003c\/summary\u003e\n        \u003cp\u003eDe handleiding geeft standaard aan: bewustwording \u003e5000 ppm, lage alarmdrempel 1,5 %, hoge alarmdrempel 3 % en TWA 5000 ppm.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Dónde debe instalarse?\u003c\/summary\u003e\n        \u003cp\u003eHij moet op maximaal 30 cm van de vloer worden geïnstalleerd en op minder dan 5 m van het distributiepunt of de mogelijke CO2‑lekkage.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIs periodiek onderhoud nodig?\u003c\/summary\u003e\n        \u003cp\u003eJa. De fabrikant raadt ten minste een jaarlijkse functionele controle aan.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-downloads\"\u003e\n      \u003ch2\u003eDownloadbaar\u003c\/h2\u003e\n      \u003cdiv class=\"ibmk90-download-grid\"\u003e\n        \u003ca class=\"ibmk90-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHandleiding Mk9 \/ Mk90 in het Spaans\u003c\/a\u003e\n        \u003ca class=\"ibmk90-btn\" href=\"https:\/\/youtu.be\/1trr3C-eVzs?si=LL6plrbHB_LvbH3o\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eVídeo tutorial Mk9 \/ Mk90\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-related\"\u003e\n      \u003ch2\u003eMisschien ook interessant voor jou\u003c\/h2\u003e\n      \u003cdiv class=\"ibmk90-related-grid\"\u003e\n        \u003ca class=\"ibmk90-btn\" href=\"\/nl\/collections\/logico2-detectores-co2-seguridad-industrial-horeca\"\u003eLogiCO2‑producten\u003c\/a\u003e\n        \u003ca class=\"ibmk90-btn\" href=\"\/nl\/pages\/servicio-tecnico\"\u003eTechnisch advies en installatie\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57365629829468,"sku":"LG015","price":314.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/mk90-co2sensor-alarm-logico2.webp?v=1775040741","url":"https:\/\/installbeer.com\/nl\/products\/kit-sensor-co2-logico2-mk90","provider":"Install Beer","version":"1.0","type":"link"}