{"product_id":"conjunto-detector-o2-logico2-mk9-central-alarma","title":"Set sensori O2 LogiCO2 Mk9 con centrale e allarme","description":"\u003csection class=\"iblgo2-product iblgo2-2057\" data-brand=\"LogiCO2\" data-model=\"O2 Mk9 Detector Base SET\"\u003e\n  \u003cstyle\u003e\n    .iblgo2-product{\n      --ib-max:1120px;\n      --ib-text:#1f2328;\n      --ib-muted:#5b6573;\n      --ib-line:#e6e8eb;\n      --ib-soft:#f7f8fa;\n      --ib-soft2:#f2f4f6;\n      --ib-accent:#111111;\n      --ib-radius:18px;\n      --ib-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ib-content-size:16px;\n      --ib-content-lh:1.68;\n      --ib-h2-size:28px;\n      --ib-h3-size:20px;\n      color:var(--ib-text);\n      font-size:var(--ib-content-size);\n      line-height:var(--ib-content-lh);\n    }\n    .iblgo2-product *{box-sizing:border-box}\n    .iblgo2-wrap{max-width:var(--ib-max);margin:0 auto;padding:4px 0 36px}\n    .iblgo2-hero,.iblgo2-block,.iblgo2-specs,.iblgo2-faq,.iblgo2-downloads,.iblgo2-related{\n      background:#fff;border:1px solid var(--ib-line);border-radius:var(--ib-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ib-shadow)\n    }\n    .iblgo2-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ib-line);\n      border-radius:999px;background:var(--ib-soft);color:var(--ib-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblgo2-product h2{\n      font-size:var(--ib-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ib-accent)\n    }\n    .iblgo2-product h3{\n      font-size:var(--ib-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ib-accent)\n    }\n    .iblgo2-product p{margin:0 0 14px;font-size:var(--ib-content-size);line-height:var(--ib-content-lh)}\n    .iblgo2-product p:last-child{margin-bottom:0}\n    .iblgo2-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ib-soft);border:1px solid var(--ib-line)\n    }\n    .iblgo2-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblgo2-card{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:var(--ib-soft)\n    }\n    .iblgo2-card strong{display:block;margin-bottom:6px;color:var(--ib-accent)}\n    .iblgo2-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ib-accent);\n      background:var(--ib-soft2);border-radius:12px\n    }\n    .iblgo2-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblgo2-list-grid li{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:#fff\n    }\n    .iblgo2-list-grid li strong{display:block;margin-bottom:6px}\n    .iblgo2-bullets{margin:0;padding-left:18px}\n    .iblgo2-bullets li{margin:0 0 10px}\n    .iblgo2-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblgo2-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ib-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblgo2-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ib-accent)\n    }\n    .iblgo2-table thead th{\n      background:var(--ib-soft2);color:var(--ib-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);font-size:15px\n    }\n    .iblgo2-table tbody th,.iblgo2-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblgo2-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ib-accent)}\n    .iblgo2-table tbody tr:last-child th,.iblgo2-table tbody tr:last-child td{border-bottom:none}\n    .iblgo2-download-grid,.iblgo2-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblgo2-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ib-accent);text-decoration:none;color:var(--ib-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblgo2-btn:hover{transform:translateY(-1px);box-shadow:var(--ib-shadow)}\n    .iblgo2-faq details{\n      border:1px solid var(--ib-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblgo2-faq details:last-child{margin-bottom:0}\n    .iblgo2-faq summary{cursor:pointer;font-weight:700;color:var(--ib-accent)}\n    .iblgo2-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblgo2-cards,.iblgo2-list-grid,.iblgo2-download-grid,.iblgo2-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblgo2-product{\n        --ib-content-size:15px;\n        --ib-h2-size:23px;\n        --ib-h3-size:18px;\n      }\n      .iblgo2-hero,.iblgo2-block,.iblgo2-specs,.iblgo2-faq,.iblgo2-downloads,.iblgo2-related{\n        padding:18px;border-radius:16px\n      }\n      .iblgo2-table{min-width:100%;border:0}\n      .iblgo2-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblgo2-table,.iblgo2-table tbody,.iblgo2-table tr,.iblgo2-table th,.iblgo2-table td{\n        display:block;width:100%\n      }\n      .iblgo2-table tr{\n        border:1px solid var(--ib-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblgo2-table tbody th{\n        background:var(--ib-soft2);border-bottom:1px solid var(--ib-line)\n      }\n      .iblgo2-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblgo2-wrap\"\u003e\n    \u003cdiv class=\"iblgo2-hero\"\u003e\n      \u003cdiv class=\"iblgo2-kicker\"\u003eSicurezza O2 · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eRivelatore di O2 LogiCO2 Mk9 per monitorare livelli di ossigeno non sicuri\u003c\/h2\u003e\n      \u003cp class=\"iblgo2-snippet\"\u003e\u003cstrong\u003eIl gruppo rivelatore di O2 LogiCO2 Mk9 integra sensore ottico, unità centrale e sirena\/lampada per rilevare livelli non sicuri di ossigeno in ambienti chiusi con azoto o altri gas asfissianti e avvisare in modo visivo e acustico.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eCosa offre questo prodotto\u003c\/h2\u003e\n      \u003cp\u003eQuesto sistema è pensato per sorvegliare zone in cui il livello di ossigeno può scendere al di sotto di una soglia di sicurezza. È particolarmente adatto a sale tecniche, celle frigorifere, locali con azoto, generatori di azoto, serbatoi di azoto e aree con gas miscelato con azoto.\u003c\/p\u003e\n      \u003cp\u003eRispetto ad apparecchi isolati, questo kit riunisce già sensore di O2 Mk9, unità centrale Mk9, sirena\/lampada stroboscopica, alimentatore, connettori, cablaggio e segnaletica. Ciò facilita un’implementazione iniziale più ordinata e una supervisione centralizzata del sistema.\u003c\/p\u003e\n      \u003cp\u003eIl sensore utilizza la rilevazione ottica, integra la compensazione di temperatura e pressione, beneficia dell’autocalibrazione automatica e mostra sul display retroilluminato la concentrazione attuale di O2 e le ore di funzionamento.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eDati chiave\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-cards\"\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          2057\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG008\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eConfigurazione base\u003c\/strong\u003e\n          1 sensore + 1 unità centrale + 1 sirena\/lampada\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eAllarme predefinito\u003c\/strong\u003e\n          \u003c19,5 % O2\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eComunicazione\u003c\/strong\u003e\n          RS485 Modbus\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eEspansione del sistema\u003c\/strong\u003e\n          Fino a 8 sensori\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblgo2-note\"\u003e\n        \u003cstrong\u003eImportante:\u003c\/strong\u003e questo prodotto non serve per rilevare CO2. È progettato per monitorare i livelli di ossigeno in ambienti chiusi con rischio di atmosfera povera di O2, in particolare dove sono presenti azoto o gas asfissianti.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eCaratteristiche principali\u003c\/h2\u003e\n      \u003cul class=\"iblgo2-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSistema completo di sicurezza O2\u003c\/strong\u003e Include sensore, centrale, sirena\/lampada, alimentatore, connettori, cartelli e manuale.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSensore ottico a lunga durata\u003c\/strong\u003e LogiCO2 evita le tradizionali celle elettrochimiche e utilizza una rilevazione ottica con autocalibrazione.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSupervisione centralizzata\u003c\/strong\u003e L’unità centrale visualizza i valori di O2, gli allarmi e il sensore che genera l’anomalia.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAllarme visivo e acustico\u003c\/strong\u003e La centrale e la sirena\/lampada avvisano quando si raggiungono livelli di ossigeno non sicuri.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFino a 8 sensori\u003c\/strong\u003e Il sistema può essere ampliato con sensori O2 Mk9 e supporta anche sensori CO2 Mk9 o Mk90 secondo il manuale.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompensazione dell’altitudine\u003c\/strong\u003e Il sensore è dotato di compensazione dell’altitudine.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eInstallazione ad altezza di respirazione\u003c\/strong\u003e Progettato per essere montato tra 150 e 180 cm dal pavimento.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUso interno professionale\u003c\/strong\u003e Destinato a spazi chiusi in cui un deficit di O2 può compromettere la sicurezza.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-specs\"\u003e\n      \u003ch2\u003eSpecifiche tecniche\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-table-wrap\"\u003e\n        \u003ctable class=\"iblgo2-table\"\u003e\n          \u003ccaption\u003eSpecifiche tecniche confermate del set rivelatore di O2 LogiCO2 Mk9\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarca\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModello\u003c\/th\u003e\n              \u003ctd\u003eO2 Mk9 Detector Base SET\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG008\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e2057\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTipo di apparecchiatura\u003c\/th\u003e\n              \u003ctd\u003eSistema di sicurezza O2 con sensore remoto, unità centrale e sirena\/lampada stroboscopica\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConfigurazione del set\u003c\/th\u003e\n              \u003ctd\u003eSensore O2 Mk9 + Unità centrale Mk9 + Sirena\/lampada LED ambra + trasformatore + cablaggio + segnaletica\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eNumero di sensori\u003c\/th\u003e\n              \u003ctd\u003e1–8\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAlimentazione del sistema\u003c\/th\u003e\n              \u003ctd\u003e12-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAlimentazione del sensore\u003c\/th\u003e\n              \u003ctd\u003e24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConsumo del sensore\u003c\/th\u003e\n              \u003ctd\u003e\u003c30 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConnessioni di cablaggio\u003c\/th\u003e\n              \u003ctd\u003eRJ45\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eInterfaz digital\u003c\/th\u003e\n              \u003ctd\u003ePorta seriale RS485 Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUscite del sensore\u003c\/th\u003e\n              \u003ctd\u003e2 uscite a transistor 24 V CC, min. 1 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDisplay del sensore\u003c\/th\u003e\n              \u003ctd\u003eGráfica 128x64, retroiluminada\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDisplay dell’unità centrale\u003c\/th\u003e\n              \u003ctd\u003eGráfica 128x64, retroiluminada\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSegnale acustico del sensore\u003c\/th\u003e\n              \u003ctd\u003e76 dBa (1 m) max.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSegnale acustico dell’unità centrale\u003c\/th\u003e\n              \u003ctd\u003eIl manuale descrive un avviso acustico interno; l’intensità non è indicata nella scheda prodotto\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePrincipio di funzionamento\u003c\/th\u003e\n              \u003ctd\u003eFB-ottico\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCampo di misura O2\u003c\/th\u003e\n              \u003ctd\u003e0-100 % vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePrecisione di O2\u003c\/th\u003e\n              \u003ctd\u003e\u003c2 % FC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAllarme predefinito\u003c\/th\u003e\n              \u003ctd\u003e\u003c19,5 % O2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAjuste adicional\u003c\/th\u003e\n              \u003ctd\u003eCompensación de altitud\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura ambiente del sensore\u003c\/th\u003e\n              \u003ctd\u003eDa -20 a +40 °C. Solo per uso interno.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensiones del sensor\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtezione del sensore\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza tensión nominal\u003c\/th\u003e\n              \u003ctd\u003e18-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/lampada corrente media\u003c\/th\u003e\n              \u003ctd\u003e120 mA a 24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDecibel sirena\/lampada\u003c\/th\u003e\n              \u003ctd\u003e110 dB \/ 1 m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIntensità flash sirena\/lampada\u003c\/th\u003e\n              \u003ctd\u003e115 cd\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFrequenza del flash sirena\/lampada\u003c\/th\u003e\n              \u003ctd\u003e65\/min\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/lampada temperatura ambiente\u003c\/th\u003e\n              \u003ctd\u003eDa -5 a +50 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza dimensiones\u003c\/th\u003e\n              \u003ctd\u003e134 x 115 x 61 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/lampada di protezione\u003c\/th\u003e\n              \u003ctd\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCapacità dell’unità centrale\u003c\/th\u003e\n              \u003ctd\u003eFino a 8 sensori; visualizza i valori di O2 e il sensore che genera l’allarme\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIndicatori dell’unità centrale\u003c\/th\u003e\n              \u003ctd\u003eLED verde funzionamento, LED rosso allarme, LED giallo guasto, pulsante silenzio\/reset\/test\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eContenuto della fornitura\u003c\/th\u003e\n              \u003ctd\u003eUnità centrale Mk9, cavo rosso 5 m, sensore di O2 Mk9, cavo rosso 10 m, cavo blu 5 m, sirena\/lampada stroboscopica con LED ambra e cavo da 1 m, sdoppiatore RJ45 1-1, sdoppiatore RJ45 1-2, trasformatore da 1 A, spine UL\/CE\/AU\/R.U., blocco spina, sacchetto con 6 viti e tasselli, cartello del sistema di sicurezza O2 Mk9, cartello sirena\/lampada stroboscopica Mk9 e manuale di installazione O2 Mk9\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGTIN\/EAN\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCodice SA\/HS\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePeso\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eCompatibilità e casi d’uso\u003c\/h2\u003e\n      \u003cp\u003eQuesto sistema viene utilizzato in spazi chiusi in cui esiste il rischio di una concentrazione non sicura di ossigeno. Il manuale stesso colloca il sensore in punti di distribuzione di azoto, generatori di azoto, serbatoi di azoto e zone con gas miscelato con azoto.\u003c\/p\u003e\n      \u003cp\u003ePuò essere utilizzato anche quando il gas asfissiante è stoccato all’esterno dell’edificio ma entra all’interno tramite tubazioni, purché la zona monitorata sia quella in cui esiste effettivamente il rischio per le persone.\u003c\/p\u003e\n      \u003cp\u003eIl sistema può essere ampliato con fino a otto sensori di O2 Mk9 e, secondo il manuale, l’unità centrale può anche lavorare con sensori di CO2 Mk9 e Mk90 all’interno dell’architettura LogiCO2.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eInstallazione e considerazioni prima dell’acquisto\u003c\/h2\u003e\n      \u003cul class=\"iblgo2-bullets\"\u003e\n        \u003cli\u003eIl sensore di O2 deve essere montato all’altezza del respiro, tra 150 e 180 cm dal pavimento.\u003c\/li\u003e\n        \u003cli\u003eLa sirena\/lampada deve essere installata sopra il sensore, a circa 2-2,4 m dal pavimento e visibile da qualsiasi ingresso della zona sorvegliata.\u003c\/li\u003e\n        \u003cli\u003eSi consiglia di installare una seconda sirena\/lampada all’esterno dell’area sorvegliata, preferibilmente sopra la porta o le porte di accesso.\u003c\/li\u003e\n        \u003cli\u003eL’unità centrale deve essere installata fuori dalla zona o dal locale sorvegliato, in una posizione visibile e accessibile.\u003c\/li\u003e\n        \u003cli\u003eSe il locale dispone solo di ventilazione meccanica, il manuale indica che deve essere dotato di sensore.\u003c\/li\u003e\n        \u003cli\u003eSe si utilizza un generatore di azoto nella stessa zona, l’eccesso di ossigeno generato deve essere convogliato all’esterno; il manuale indica che non è consentito usare il sensore nella zona se tale ossigeno non viene estratto.\u003c\/li\u003e\n        \u003cli\u003eIl sistema non funziona se viene scollegato dalla rete elettrica, pertanto l’alimentazione e il relativo blocco meccanico devono essere verificati prima della messa in servizio.\u003c\/li\u003e\n        \u003cli\u003eIn quanto dispositivo di sicurezza, installazione e manutenzione devono essere eseguite esclusivamente da professionisti.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eManutenzione e uso consigliato\u003c\/h2\u003e\n      \u003cp\u003eIl sensore di O2 LogiCO2 integra un’autocalibrazione automatica attivata di serie e non dovrebbe richiedere calibrazione manuale in condizioni normali, purché resti acceso in modo continuo. Tuttavia, lo stesso produttore indica che è necessaria una calibrazione manuale al momento dell’avviamento.\u003c\/p\u003e\n      \u003cp\u003eInoltre, trattandosi di un prodotto di sicurezza, si raccomanda di effettuare un controllo del funzionamento almeno una volta all’anno. La pulizia va eseguita con acqua e un panno inumidito, e il sensore e il contenitore dell’unità centrale non devono essere aperti da personale non autorizzato.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-faq\"\u003e\n      \u003ch2\u003eDomande frequenti\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eQuesto sistema rileva il CO2?\u003c\/summary\u003e\n        \u003cp\u003eNo. Questo prodotto è progettato per rilevare livelli non sicuri di ossigeno in spazi chiusi.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCosa include esattamente il set 2057?\u003c\/summary\u003e\n        \u003cp\u003eInclude sensore di O2 Mk9, unità centrale Mk9, sirena\/lampada stroboscopica, trasformatore, cablaggio, connettori RJ45, segnaletica e manuale di installazione.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDove deve essere installato il sensore di O2?\u003c\/summary\u003e\n        \u003cp\u003eDeve essere installato all’altezza del respiro, tra 150 e 180 cm dal pavimento, nella zona in cui esista realmente rischio di atmosfera non sicura.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDove si installano la sirena\/lampada e l’unità centrale?\u003c\/summary\u003e\n        \u003cp\u003eLa sirena\/lampada deve essere posizionata sopra il sensore, a circa 2-2,4 m dal pavimento. L’unità centrale deve essere montata fuori dalla zona sorvegliata, in un punto chiaramente visibile e accessibile.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eQual è il livello di allarme predefinito?\u003c\/summary\u003e\n        \u003cp\u003eIl produttore indica un livello di allarme predefinito di 19,5 % di O2.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Necesita mantenimiento periódico?\u003c\/summary\u003e\n        \u003cp\u003eSì. Sebbene disponga di autocalibrazione automatica, si raccomanda una verifica funzionale almeno una volta all’anno e una calibrazione manuale iniziale all’avvio del sistema.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-downloads\"\u003e\n      \u003ch2\u003eScaricabili\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-download-grid\"\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/O2_Mk9_Detector_BaseSET_2057_es_db_LogiCO2.pdf?v=1775037461\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eScheda tecnica LogiCO2 2057\u003c\/a\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/o2ss_mk9_2057_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManuale O2 Mk9\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-related\"\u003e\n      \u003ch2\u003eTambién puede interesarte\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-related-grid\"\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"\/it\/collections\/alarmas-detectores-logico2\"\u003eAllarmi e rivelatori LogiCO2\u003c\/a\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"\/it\/pages\/servicio-tecnico\"\u003eAsesoramiento e instalación técnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57238900572508,"sku":"LG008","price":1090.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/o2-mk9detector-set-logic2.webp?v=1775037730","url":"https:\/\/installbeer.com\/it\/products\/set-rilevatore-o2-logico2-mk9-centrale-allarme","provider":"Install Beer","version":"1.0","type":"link"}