{"product_id":"kit-adicional-sensor-o2-logico2-mk9","title":"Kit aggiuntivo sensore O2 LogiCO2 Mk9 con sirena e cablaggio","description":"\u003csection class=\"ibo2kit-product ibo2kit-2125\" data-brand=\"LogiCO2\" data-model=\"O2 Mk9 Sensor Add-on KIT\"\u003e\n  \u003cstyle\u003e\n    .ibo2kit-product{\n      --ibo2kit-max:1120px;\n      --ibo2kit-text:#1f2328;\n      --ibo2kit-muted:#5b6573;\n      --ibo2kit-line:#e6e8eb;\n      --ibo2kit-soft:#f7f8fa;\n      --ibo2kit-soft2:#f2f4f6;\n      --ibo2kit-accent:#111111;\n      --ibo2kit-radius:18px;\n      --ibo2kit-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibo2kit-content-size:16px;\n      --ibo2kit-content-lh:1.68;\n      --ibo2kit-h2-size:28px;\n      --ibo2kit-h3-size:20px;\n      color:var(--ibo2kit-text);\n      font-size:var(--ibo2kit-content-size);\n      line-height:var(--ibo2kit-content-lh);\n    }\n    .ibo2kit-product *{box-sizing:border-box}\n    .ibo2kit-wrap{max-width:var(--ibo2kit-max);margin:0 auto;padding:4px 0 36px}\n    .ibo2kit-hero,.ibo2kit-block,.ibo2kit-specs,.ibo2kit-faq,.ibo2kit-downloads,.ibo2kit-related{\n      background:#fff;border:1px solid var(--ibo2kit-line);border-radius:var(--ibo2kit-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibo2kit-shadow)\n    }\n    .ibo2kit-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibo2kit-line);\n      border-radius:999px;background:var(--ibo2kit-soft);color:var(--ibo2kit-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibo2kit-product h2{\n      font-size:var(--ibo2kit-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibo2kit-accent)\n    }\n    .ibo2kit-product h3{\n      font-size:var(--ibo2kit-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibo2kit-accent)\n    }\n    .ibo2kit-product p{margin:0 0 14px;font-size:var(--ibo2kit-content-size);line-height:var(--ibo2kit-content-lh)}\n    .ibo2kit-product p:last-child{margin-bottom:0}\n    .ibo2kit-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibo2kit-soft);border:1px solid var(--ibo2kit-line)\n    }\n    .ibo2kit-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibo2kit-card{\n      padding:16px;border:1px solid var(--ibo2kit-line);border-radius:16px;background:var(--ibo2kit-soft)\n    }\n    .ibo2kit-card strong{display:block;margin-bottom:6px;color:var(--ibo2kit-accent)}\n    .ibo2kit-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibo2kit-accent);\n      background:var(--ibo2kit-soft2);border-radius:12px\n    }\n    .ibo2kit-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibo2kit-list-grid li{\n      padding:16px;border:1px solid var(--ibo2kit-line);border-radius:16px;background:#fff\n    }\n    .ibo2kit-list-grid li strong{display:block;margin-bottom:6px}\n    .ibo2kit-bullets{margin:0;padding-left:18px}\n    .ibo2kit-bullets li{margin:0 0 10px}\n    .ibo2kit-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibo2kit-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibo2kit-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibo2kit-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibo2kit-accent)\n    }\n    .ibo2kit-table thead th{\n      background:var(--ibo2kit-soft2);color:var(--ibo2kit-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibo2kit-line);font-size:15px\n    }\n    .ibo2kit-table tbody th,.ibo2kit-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibo2kit-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibo2kit-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibo2kit-accent)}\n    .ibo2kit-table tbody tr:last-child th,.ibo2kit-table tbody tr:last-child td{border-bottom:none}\n    .ibo2kit-download-grid,.ibo2kit-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibo2kit-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibo2kit-accent);text-decoration:none;color:var(--ibo2kit-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibo2kit-btn:hover{transform:translateY(-1px);box-shadow:var(--ibo2kit-shadow)}\n    .ibo2kit-faq details{\n      border:1px solid var(--ibo2kit-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibo2kit-faq details:last-child{margin-bottom:0}\n    .ibo2kit-faq summary{cursor:pointer;font-weight:700;color:var(--ibo2kit-accent)}\n    .ibo2kit-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibo2kit-cards,.ibo2kit-list-grid,.ibo2kit-download-grid,.ibo2kit-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibo2kit-product{\n        --ibo2kit-content-size:15px;\n        --ibo2kit-h2-size:23px;\n        --ibo2kit-h3-size:18px;\n      }\n      .ibo2kit-hero,.ibo2kit-block,.ibo2kit-specs,.ibo2kit-faq,.ibo2kit-downloads,.ibo2kit-related{\n        padding:18px;border-radius:16px\n      }\n      .ibo2kit-table{min-width:100%;border:0}\n      .ibo2kit-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibo2kit-table,.ibo2kit-table tbody,.ibo2kit-table tr,.ibo2kit-table th,.ibo2kit-table td{\n        display:block;width:100%\n      }\n      .ibo2kit-table tr{\n        border:1px solid var(--ibo2kit-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibo2kit-table tbody th{\n        background:var(--ibo2kit-soft2);border-bottom:1px solid var(--ibo2kit-line)\n      }\n      .ibo2kit-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibo2kit-wrap\"\u003e\n    \u003cdiv class=\"ibo2kit-hero\"\u003e\n      \u003cdiv class=\"ibo2kit-kicker\"\u003eSicurezza O2 · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eKit aggiuntivo di sensore O2 LogiCO2 Mk9 per ampliare un sistema esistente\u003c\/h2\u003e\n      \u003cp class=\"ibo2kit-snippet\"\u003e\u003cstrong\u003eIl kit aggiuntivo di sensore di O2 LogiCO2 Mk9 è una soluzione plug and play per aggiungere un secondo punto di rilevazione a un sistema di sicurezza già installato, con sensore O2, sirena\/baliza, cablaggio e segnaletica inclusi.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2kit-block\"\u003e\n      \u003ch2\u003eCosa offre questo prodotto\u003c\/h2\u003e\n      \u003cp\u003eQuesto kit è pensato per ampliare un sistema LogiCO2 già esistente senza dover installare un insieme completo da zero. La sua funzione è aggiungere un sensore extra di ossigeno con la propria segnalazione locale.\u003c\/p\u003e\n      \u003cp\u003eIl suo principale vantaggio è che arriva preconfigurato come sensore aggiuntivo, con indirizzo ID2 e alimentazione prelevata dal sistema esistente. Questo semplifica l’ampliamento quando l’impianto deve sorvegliare una seconda zona.\u003c\/p\u003e\n      \u003cp\u003eIn Install Beer, in qualità di distributori ufficiali in Europa e servizio tecnico per montaggio e manutenzione, questo tipo di kit è particolarmente indicato per ampliamenti, adeguamenti di sicurezza e manutenzioni evolutive di impianti già operativi.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2kit-block\"\u003e\n      \u003ch2\u003eDati chiave\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2kit-cards\"\u003e\n        \u003cdiv class=\"ibo2kit-card\"\u003e\n          \u003cstrong\u003eCodice produttore\u003c\/strong\u003e\n          2125\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2kit-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG019\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2kit-card\"\u003e\n          \u003cstrong\u003eTipo\u003c\/strong\u003e\n          Kit aggiuntivo plug and play\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2kit-card\"\u003e\n          \u003cstrong\u003eSensore preconfigurato\u003c\/strong\u003e\n          ID2\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2kit-card\"\u003e\n          \u003cstrong\u003eNumero massimo di sensori\u003c\/strong\u003e\n          Fino a 8\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2kit-card\"\u003e\n          \u003cstrong\u003eAllarme predefinito\u003c\/strong\u003e\n          19,5 % O2\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"ibo2kit-note\"\u003e\n        \u003cstrong\u003eImportante:\u003c\/strong\u003e questo kit è un sensore aggiuntivo per un sistema già esistente. L’unità centrale deve essere configurata per ricevere i valori di due sensori, o del numero totale di sensori installati.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2kit-block\"\u003e\n      \u003ch2\u003eCaratteristiche principali\u003c\/h2\u003e\n      \u003cul class=\"ibo2kit-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eKit completo di ampliamento\u003c\/strong\u003e Include sensore O2 Mk9 con display, sirena\/lampada, cavi, connettori e segnaletica.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFormato plug and play\u003c\/strong\u003e È predisposto come kit aggiuntivo per ampliare un sistema LogiCO2 già operativo.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSensore preimpostato su ID2\u003c\/strong\u003e Il produttore lo fornisce configurato come sensore aggiuntivo con indirizzo ID2.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAlimentazione dal sistema esistente\u003c\/strong\u003e Non necessita di un proprio alimentatore indipendente se il sistema è correttamente dimensionato.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMisurazione ottica di O2\u003c\/strong\u003e Il sensore utilizza principio FB-ottico e misura la concentrazione di ossigeno tra 0 e 25%.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAutocalibrazione automatica\u003c\/strong\u003e Il sensore effettua l’autocalibrazione a intervalli regolari in condizioni normali.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDisplay retroilluminato\u003c\/strong\u003e Mostra la concentrazione attuale di O2 e il tempo di funzionamento in ore.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eEspandibile fino a 8 sensori\u003c\/strong\u003e Il sistema può crescere fino a otto sensori collegati.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2kit-specs\"\u003e\n      \u003ch2\u003eSpecifiche tecniche\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2kit-table-wrap\"\u003e\n        \u003ctable class=\"ibo2kit-table\"\u003e\n          \u003ccaption\u003eSpecifiche tecniche confermate del kit aggiuntivo di sensore di O2 LogiCO2 Mk9\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParametro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confermato\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarca\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModello\u003c\/th\u003e\n              \u003ctd\u003eO2 Mk9 Sensor Add-on KIT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG019\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ codice articolo del produttore\u003c\/th\u003e\n              \u003ctd\u003e2125\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTipo di apparecchiatura\u003c\/th\u003e\n              \u003ctd\u003eKit aggiuntivo di sensore di ossigeno per sistema di sicurezza esistente\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConfigurazione di fabbrica\u003c\/th\u003e\n              \u003ctd\u003eSensore aggiuntivo preconfigurato con indirizzo ID2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAlimentazione del kit\u003c\/th\u003e\n              \u003ctd\u003eDal sistema di sicurezza esistente\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eNumero massimo di sensori nel sistema\u003c\/th\u003e\n              \u003ctd\u003eFino a 8 sensori\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLivelli di allarme predefiniti\u003c\/th\u003e\n              \u003ctd\u003eAllarme di evacuazione: 19,5 % O2; è possibile configurare fino a 3 livelli diversi tramite DIP‑switch\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensore incluso\u003c\/th\u003e\n              \u003ctd\u003eO2 Sensor Mk9\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAlimentazione del sensore\u003c\/th\u003e\n              \u003ctd\u003e24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePrincipio di funzionamento\u003c\/th\u003e\n              \u003ctd\u003eFB-ottico\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCampo di misura\u003c\/th\u003e\n              \u003ctd\u003e0–25 % O2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePrecisión\u003c\/th\u003e\n              \u003ctd\u003e\u003c2 % FS\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIndicazioni LED del sensore\u003c\/th\u003e\n              \u003ctd\u003eVerde: funzionamento · Giallo: guasto · Rosso: allarme (\u003c19,5 % O2)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIndicazioni acustiche del sensore\u003c\/th\u003e\n              \u003ctd\u003eIntermittente: guasto · Continuo: allarme\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDisplay del sensore\u003c\/th\u003e\n              \u003ctd\u003eRetroilluminato; mostra la concentrazione attuale di O2 e il tempo di funzionamento in ore\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensioni del sensore\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtezione del sensore\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/lampada inclusa\u003c\/th\u003e\n              \u003ctd\u003eHorn\/Strobe LED ambra\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTensione nominale sirena\/lampada\u003c\/th\u003e\n              \u003ctd\u003e18-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCorrente media sirena\/lampada\u003c\/th\u003e\n              \u003ctd\u003e120 mA a 24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLivello acustico sirena\/baliza\u003c\/th\u003e\n              \u003ctd\u003e110 dB \/ 1 m (alarma alta)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIntensità del flash\u003c\/th\u003e\n              \u003ctd\u003e115 CD (alarma baja)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFrequenza del flash\u003c\/th\u003e\n              \u003ctd\u003e65\/min\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura ambiente sirena\/lampada\u003c\/th\u003e\n              \u003ctd\u003e-5 °C a +50 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensioni sirena\/lampada\u003c\/th\u003e\n              \u003ctd\u003e134 x 115 x 61 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtezione sirena\/lampada\u003c\/th\u003e\n              \u003ctd\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eContenuto della fornitura\u003c\/th\u003e\n              \u003ctd\u003eRilevatore O2 Mk9 + Horn\/Strobe LED con cavo + cavo di alimentazione\/comunicazione da 10 m + plug lock + cavo di segnalazione da 5 m + 1 connettore RJ45 1-1 + 1 connettore RJ45 1-4 + manuale + cartello H\/S\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePeso\u003c\/th\u003e\n              \u003ctd\u003e3 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2kit-block\"\u003e\n      \u003ch2\u003eCompatibilità e casi d’uso\u003c\/h2\u003e\n      \u003cp\u003eQuesto kit è pensato per aggiungere un sensore in più a un sistema di sicurezza O2 LogiCO2 già installato. È particolarmente utile quando l’impianto cresce o quando compare una seconda zona che deve essere anch’essa monitorata.\u003c\/p\u003e\n      \u003cp\u003eÈ adatto a sale tecniche, celle frigorifere, zone con rischio di atmosfera povera di ossigeno, impianti con azoto e altri ambienti in cui una sola unità di rilevazione non copre l’intera area a rischio.\u003c\/p\u003e\n      \u003cp\u003eLa stessa documentazione indica che l’unità centrale deve essere regolata in base al nuovo numero totale di sensori collegati.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2kit-block\"\u003e\n      \u003ch2\u003eInstallazione e considerazioni prima dell’acquisto\u003c\/h2\u003e\n      \u003cul class=\"ibo2kit-bullets\"\u003e\n        \u003cli\u003eIl sensore deve essere installato all’altezza del respiro, tra 150 e 180 cm dal pavimento.\u003c\/li\u003e\n        \u003cli\u003eLa sirena\/lampada deve essere montata sopra il sensore, a circa 2-2,4 m dal pavimento e visibile da qualsiasi ingresso.\u003c\/li\u003e\n        \u003cli\u003eL’unità centrale deve rimanere fuori dalla zona sorvegliata, in un punto visibile e accessibile.\u003c\/li\u003e\n        \u003cli\u003ePrima dell’acquisto, conferma che il tuo sistema esistente possa accettare un sensore aggiuntivo e che la centrale possa essere riconfigurata al nuovo numero di sensori.\u003c\/li\u003e\n        \u003cli\u003eVerifica inoltre che il dimensionamento elettrico del sistema consenta l’ampliamento con questo kit aggiuntivo.\u003c\/li\u003e\n        \u003cli\u003eSe il sistema dispone solo di ventilazione meccanica, il manuale indica che il locale deve avere un sensore.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2kit-block\"\u003e\n      \u003ch2\u003eManutenzione e uso consigliato\u003c\/h2\u003e\n      \u003cp\u003eIl sensore O2 Mk9 esegue un’autocalibrazione automatica a intervalli regolari, riducendo la necessità di calibrazione manuale in un ambiente normale.\u003c\/p\u003e\n      \u003cp\u003eAnche così, trattandosi di un prodotto di sicurezza, è opportuno effettuare verifiche funzionali periodiche e controllare dopo l’installazione che il nuovo sensore compaia correttamente in centrale e che la segnalazione locale risponda come deve.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2kit-faq\"\u003e\n      \u003ch2\u003eDomande frequenti\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eQuesto kit serve per installare un sistema completo da zero?\u003c\/summary\u003e\n        \u003cp\u003eNo. È progettato come sensore aggiuntivo per un sistema di sicurezza LogiCO2 già esistente.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCome è configurato in fabbrica?\u003c\/summary\u003e\n        \u003cp\u003eViene preconfigurato come ID2, cioè come secondo sensore del sistema.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCosa include esattamente il kit O2 MK9?\u003c\/summary\u003e\n        \u003cp\u003eInclude sensore O2 Mk9 con display, sirena\/lampada, cablaggio, connettori RJ45, manuale e segnaletica.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eQuanti sensori supporta il sistema LogiCO2?\u003c\/summary\u003e\n        \u003cp\u003eLa pagina ufficiale indica che si possono collegare fino a otto sensori.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDove deve essere installato il sensore di O2?\u003c\/summary\u003e\n        \u003cp\u003eDeve essere installato all’altezza del respiro, tra 150 e 180 cm dal pavimento.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eQual è il livello di allarme predefinito?\u003c\/summary\u003e\n        \u003cp\u003eL’allarme di evacuazione è preimpostato a 19,5 % di O2.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2kit-downloads\"\u003e\n      \u003ch2\u003eScaricabili\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2kit-download-grid\"\u003e\n        \u003ca class=\"ibo2kit-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/O2_Mk9_Sensor_AddonKIT_LogiCO2.pdf?v=1776206793\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eScheda tecnica kit sensore O2\u003c\/a\u003e\n        \u003ca class=\"ibo2kit-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/o2ss_mk9_2057_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManuale sistema O2 Mk9 in spagnolo\u003c\/a\u003e\n        \u003ca class=\"ibo2kit-btn\" href=\"https:\/\/youtu.be\/vnqd216J2eY?si=q4omM64pWNflM4OH\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eVideo tutorial installazione O2 Mk9\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2kit-related\"\u003e\n      \u003ch2\u003ePotrebbe interessarti anche\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2kit-related-grid\"\u003e\n        \u003ca class=\"ibo2kit-btn\" href=\"\/it-mc\/collections\/logico2-detectores-co2-seguridad-industrial-horeca\"\u003eProdotti LogiCO2\u003c\/a\u003e\n        \u003ca class=\"ibo2kit-btn\" href=\"\/it-mc\/pages\/servicio-tecnico\"\u003eConsulenza e installazione tecnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57365630910812,"sku":"LG019","price":840.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/o2-mk9sensor-kit-logico2.webp?v=1776207071","url":"https:\/\/installbeer.com\/it-mc\/products\/kit-aggiuntivo-sensore-o2-logico2-mk9","provider":"Install Beer","version":"1.0","type":"link"}