{"product_id":"kit-adicional-power-barrier-logico2-sistema-seguridad-co2","title":"Kit aggiuntivo Power Barrier LogiCO2 per sistema di sicurezza CO2","description":"\u003csection class=\"ibpb-product ibpb-0482\" data-brand=\"LogiCO2\" data-model=\"Power Barrier Add-on KIT\"\u003e\n  \u003cstyle\u003e\n    .ibpb-product{\n      --ibpb-max:1120px;\n      --ibpb-text:#1f2328;\n      --ibpb-muted:#5b6573;\n      --ibpb-line:#e6e8eb;\n      --ibpb-soft:#f7f8fa;\n      --ibpb-soft2:#f2f4f6;\n      --ibpb-accent:#111111;\n      --ibpb-radius:18px;\n      --ibpb-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibpb-content-size:16px;\n      --ibpb-content-lh:1.68;\n      --ibpb-h2-size:28px;\n      --ibpb-h3-size:20px;\n      color:var(--ibpb-text);\n      font-size:var(--ibpb-content-size);\n      line-height:var(--ibpb-content-lh);\n    }\n    .ibpb-product *{box-sizing:border-box}\n    .ibpb-wrap{max-width:var(--ibpb-max);margin:0 auto;padding:4px 0 36px}\n    .ibpb-hero,.ibpb-block,.ibpb-specs,.ibpb-faq,.ibpb-downloads,.ibpb-related{\n      background:#fff;border:1px solid var(--ibpb-line);border-radius:var(--ibpb-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibpb-shadow)\n    }\n    .ibpb-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibpb-line);\n      border-radius:999px;background:var(--ibpb-soft);color:var(--ibpb-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibpb-product h2{\n      font-size:var(--ibpb-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibpb-accent)\n    }\n    .ibpb-product h3{\n      font-size:var(--ibpb-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibpb-accent)\n    }\n    .ibpb-product p{\n      margin:0 0 14px;\n      font-size:var(--ibpb-content-size);\n      line-height:var(--ibpb-content-lh)\n    }\n    .ibpb-product p:last-child{margin-bottom:0}\n    .ibpb-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibpb-soft);border:1px solid var(--ibpb-line)\n    }\n    .ibpb-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibpb-card{\n      padding:16px;border:1px solid var(--ibpb-line);border-radius:16px;background:var(--ibpb-soft)\n    }\n    .ibpb-card strong{display:block;margin-bottom:6px;color:var(--ibpb-accent)}\n    .ibpb-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibpb-accent);\n      background:var(--ibpb-soft2);border-radius:12px\n    }\n    .ibpb-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibpb-list-grid li{\n      padding:16px;border:1px solid var(--ibpb-line);border-radius:16px;background:#fff\n    }\n    .ibpb-list-grid li strong{display:block;margin-bottom:6px}\n    .ibpb-bullets{margin:0;padding-left:18px}\n    .ibpb-bullets li{margin:0 0 10px}\n    .ibpb-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibpb-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibpb-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibpb-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibpb-accent)\n    }\n    .ibpb-table thead th{\n      background:var(--ibpb-soft2);color:var(--ibpb-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibpb-line);font-size:15px\n    }\n    .ibpb-table tbody th,.ibpb-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibpb-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibpb-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibpb-accent)}\n    .ibpb-table tbody tr:last-child th,.ibpb-table tbody tr:last-child td{border-bottom:none}\n    .ibpb-download-grid,.ibpb-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibpb-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibpb-accent);text-decoration:none;color:var(--ibpb-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibpb-btn:hover{transform:translateY(-1px);box-shadow:var(--ibpb-shadow)}\n    .ibpb-faq details{\n      border:1px solid var(--ibpb-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibpb-faq details:last-child{margin-bottom:0}\n    .ibpb-faq summary{cursor:pointer;font-weight:700;color:var(--ibpb-accent)}\n    .ibpb-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibpb-cards,.ibpb-list-grid,.ibpb-download-grid,.ibpb-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibpb-product{\n        --ibpb-content-size:15px;\n        --ibpb-h2-size:23px;\n        --ibpb-h3-size:18px;\n      }\n      .ibpb-hero,.ibpb-block,.ibpb-specs,.ibpb-faq,.ibpb-downloads,.ibpb-related{\n        padding:18px;border-radius:16px\n      }\n      .ibpb-table{min-width:100%;border:0}\n      .ibpb-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibpb-table,.ibpb-table tbody,.ibpb-table tr,.ibpb-table th,.ibpb-table td{\n        display:block;width:100%\n      }\n      .ibpb-table tr{\n        border:1px solid var(--ibpb-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibpb-table tbody th{\n        background:var(--ibpb-soft2);border-bottom:1px solid var(--ibpb-line)\n      }\n      .ibpb-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibpb-wrap\"\u003e\n    \u003cdiv class=\"ibpb-hero\"\u003e\n      \u003cdiv class=\"ibpb-kicker\"\u003eAccessorio tecnico · LogiCO2 Safety System\u003c\/div\u003e\n      \u003ch2\u003ePower Barrier LogiCO2 per ampliare l’alimentazione senza perdere la comunicazione del sistema\u003c\/h2\u003e\n      \u003cp class=\"ibpb-snippet\"\u003e\u003cstrong\u003eIl Power Barrier LogiCO2 consente di collegare più alimentatori in un unico sistema di sicurezza CO2, separando i loop di potenza per non superare i limiti su cavi e connettori, mentre i sensori continuano a comunicare con l’unità centrale.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eCosa offre questo prodotto\u003c\/h2\u003e\n      \u003cp\u003eQuesto modulo risolve un problema tipico nei sistemi LogiCO2 di grandi dimensioni o con molti elementi collegati: il consumo totale di corrente può avvicinarsi al limite sicuro di un singolo alimentatore o di un unico loop di alimentazione. In tale scenario, il Power Barrier aiuta a ripartire il carico senza rompere l’architettura di comunicazione del sistema.\u003c\/p\u003e\n      \u003cp\u003eLa sua funzione reale non è rilevare gas né attivare allarmi in modo autonomo, ma agire come accessorio di distribuzione della potenza all’interno del sistema di sicurezza LogiCO2. Consente di lavorare con più alimentatori e di mantenere elettricamente separati diversi tratti del sistema.\u003c\/p\u003e\n      \u003cp\u003eIn installazioni con più sensori, sirene, scatole remote o accessori, questo tipo di modulo aiuta a mantenere la stabilità in allarme, evitare cadute di tensione e facilitare un ampliamento più pulito dal punto di vista tecnico.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eDati chiave\u003c\/h2\u003e\n      \u003cdiv class=\"ibpb-cards\"\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eCodice produttore\u003c\/strong\u003e\n          0482\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG028\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eFunzione principale\u003c\/strong\u003e\n          Collegare più alimentatori nello stesso sistema\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eNumero massimo di alimentatori\u003c\/strong\u003e\n          Fino a 8\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eAlimentazione del modulo\u003c\/strong\u003e\n          24 V CC dal sistema di allarme\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eConsumo proprio\u003c\/strong\u003e\n          2 x 17 mA\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"ibpb-note\"\u003e\n        \u003cstrong\u003eNota tecnica di ingegneria:\u003c\/strong\u003e in Install Beer è opportuno calcolare sempre il consumo totale del sistema in condizione di allarme. Come criterio interno di validazione, si valuta di solito la necessità di un Power Barrier quando il carico si avvicina già al margine sicuro del sistema e soprattutto quando il progetto somma molteplici sensori, sirene o accessori.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eCaratteristiche principali\u003c\/h2\u003e\n      \u003cul class=\"ibpb-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eConsente più alimentatori\u003c\/strong\u003e Il produttore indica che può lavorare con fino a otto alimentatori nello stesso sistema.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eRispetta i limiti per loop\u003c\/strong\u003e Ogni alimentatore mantiene un’uscita di 1 A per non superare i limiti di potenza su cavi e connettori.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMantiene la comunicazione con la centrale\u003c\/strong\u003e Anche se i loop vengono separati in potenza, i sensori continuano a comunicare con l’unità centrale.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSeparazione galvanica dei loop\u003c\/strong\u003e L’installazione di esempio del produttore mostra più alimentatori collegati e separati galvanicamente tramite Power Barrier.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicatori LED di stato\u003c\/strong\u003e Dispone di due LED verdi per verificare che entrambi i lati siano alimentati.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFormato compatto\u003c\/strong\u003e Condivide il formato fisico abituale dei moduli LogiCO2, utile per installazioni tecniche ordinate.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAccessorio per ampliamenti reali\u003c\/strong\u003e Ha senso in sistemi con molteplici sensori, sirene, O2, Mk90, scatole remote o accessori di sicurezza aggiuntivi.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIntegrazione nell’architettura LogiCO2\u003c\/strong\u003e È pensato per il LogiCO2 Safety System, non come modulo universale indipendente.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-specs\"\u003e\n      \u003ch2\u003eSpecifiche tecniche\u003c\/h2\u003e\n      \u003cdiv class=\"ibpb-table-wrap\"\u003e\n        \u003ctable class=\"ibpb-table\"\u003e\n          \u003ccaption\u003eSpecifiche tecniche confermate del Power Barrier Add-on KIT LogiCO2 0482\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParametro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confermato\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarca\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModello\u003c\/th\u003e\n              \u003ctd\u003ePower Barrier Add-on KIT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG028\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ codice articolo del produttore\u003c\/th\u003e\n              \u003ctd\u003e0482\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTipo di apparecchiatura\u003c\/th\u003e\n              \u003ctd\u003eAccessorio di alimentazione per LogiCO2 Safety System\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFunzione\u003c\/th\u003e\n              \u003ctd\u003eConsentire il collegamento di più alimentatori in un unico sistema mantenendo la comunicazione con l’unità centrale\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eNumero massimo di alimentatori\u003c\/th\u003e\n              \u003ctd\u003eFino a 8\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCapacità per alimentatore secondo il produttore\u003c\/th\u003e\n              \u003ctd\u003e1 A di uscita per alimentatore\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAlimentazione del modulo\u003c\/th\u003e\n              \u003ctd\u003e24 V CC, forniti dal sistema di allarme\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAssorbimento di corrente\u003c\/th\u003e\n              \u003ctd\u003e2 x 17 mA, con alimentazione da due alimentatori\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUmidità\u003c\/th\u003e\n              \u003ctd\u003e0–90 % senza condensa\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura ambiente\u003c\/th\u003e\n              \u003ctd\u003e0 a +40 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensioni\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtezione contro la penetrazione\u003c\/th\u003e\n              \u003ctd\u003eIP54 secondo TÜV, IP44 secondo UL\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIndicatori\u003c\/th\u003e\n              \u003ctd\u003eLED verde superiore per il cavo sinistro e LED verde inferiore per il cavo destro; entrambi devono essere accesi per un corretto funzionamento\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOmologazioni\u003c\/th\u003e\n              \u003ctd\u003eCE; prove di emissione secondo SS-EN 61000-6-3 e di immunità secondo SS-EN 61000-6-2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCompatibilità di installazione indicata dal produttore\u003c\/th\u003e\n              \u003ctd\u003eCentral Unit Mk9 con sensori CO2 Mk9, CO2 Mk90 e sensore O2 Mk9 nello stesso sistema con più alimentatori\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConsumo di picco di riferimento del modulo stesso\u003c\/th\u003e\n              \u003ctd\u003e17 mA nella tabella di calcolo dei consumi del produttore\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eContenuto della fornitura\u003c\/th\u003e\n              \u003ctd\u003ePower Barrier Add-on KIT 0482. La documentazione fornita non dettaglia ulteriori componenti della confezione.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGTIN\/EAN\u003c\/th\u003e\n              \u003ctd\u003eDato non fornito\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCodice SA\/HS\u003c\/th\u003e\n              \u003ctd\u003eDato non fornito\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePeso\u003c\/th\u003e\n              \u003ctd\u003eDato non fornito\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eCompatibilità e casi d’uso\u003c\/h2\u003e\n      \u003cp\u003eIl Power Barrier è pensato per l’ecosistema LogiCO2 Safety System e ha senso in installazioni con più sensori, più sirene o accessori distribuiti su diversi loop di alimentazione.\u003c\/p\u003e\n      \u003cp\u003eL’installazione di esempio del produttore mostra compatibilità all’interno dello stesso sistema con un’unità centrale Mk9, sensori CO2 Mk9, sensori CO2 Mk90 e un sensore O2 Mk9, tutti in comunicazione con la centrale mentre l’alimentazione è ripartita su più fonti separate galvanicamente.\u003c\/p\u003e\n      \u003cp\u003eÈ particolarmente utile in progetti di ristorazione, cantine, birrifici, sale tecniche, impianti di bevande o installazioni industriali leggere in cui il sistema è già cresciuto e la somma dei consumi rende consigliabile suddividere la potenza per loop.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eInstallazione e considerazioni prima dell’acquisto\u003c\/h2\u003e\n      \u003cul class=\"ibpb-bullets\"\u003e\n        \u003cli\u003ePrima dell’acquisto, calcola il consumo totale del sistema in condizione di allarme, non solo in funzionamento normale.\u003c\/li\u003e\n        \u003cli\u003eLo stesso produttore ricorda che un alimentatore ha un’uscita di 1 A e fornisce una tabella dei consumi di picco per valutare se è necessario un Power Barrier.\u003c\/li\u003e\n        \u003cli\u003eVerifica quanti sensori, sirene, scatole RCB, sniffers, valvole di sicurezza o altri accessori fanno parte del sistema.\u003c\/li\u003e\n        \u003cli\u003eVerifica inoltre se il progetto utilizza più alimentatori e come sono fisicamente ripartiti i loop.\u003c\/li\u003e\n        \u003cli\u003eSe il sistema è già vicino al margine di corrente sicuro o è destinato a crescere, il Power Barrier lascia l’installazione meglio preparata per evitare problemi di tensione.\u003c\/li\u003e\n        \u003cli\u003eI due LED verdi del modulo devono rimanere attivi per confermare una corretta alimentazione su entrambi i lati.\u003c\/li\u003e\n        \u003cli\u003ePoiché è un accessorio di ingegneria del sistema, è opportuno integrarlo nel progetto complessivo e non come aggiunta improvvisata alla fine.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eManutenzione e uso consigliato\u003c\/h2\u003e\n      \u003cp\u003eIl Power Barrier non richiede un funzionamento complesso, ma è comunque consigliabile controllare periodicamente lo stato di alimentazione di entrambi i lati del modulo, il fissaggio meccanico, il cablaggio e la ripartizione dei carichi dopo eventuali ampliamenti del sistema.\u003c\/p\u003e\n      \u003cp\u003eIn pratica, ogni volta che si aggiungono sensori, sirene o accessori al sistema LogiCO2, vale la pena rifare il calcolo dei consumi e verificare che l’installazione rimanga entro margini adeguati. Questo controllo è particolarmente importante in sistemi che devono rimanere stabili durante un allarme reale.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-faq\"\u003e\n      \u003ch2\u003eDomande frequenti\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eChe cosa fa esattamente un Power Barrier LogiCO2?\u003c\/summary\u003e\n        \u003cp\u003eConsente di collegare più alimentatori in un unico sistema LogiCO2, separando i loop di potenza senza perdere la comunicazione tra sensori e unità centrale.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eServe per rilevare CO2 o per attivare allarmi?\u003c\/summary\u003e\n        \u003cp\u003eNo. È un accessorio di alimentazione e distribuzione di potenza. Non sostituisce sensori, centrale né sirene.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eQuando è solitamente necessario?\u003c\/summary\u003e\n        \u003cp\u003eDi solito ha senso in sistemi più grandi o più caricati, con diversi sensori, sirene o accessori, quando il calcolo dei consumi consiglia di ripartire l’alimentazione su più loop.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCon quante fonti può lavorare?\u003c\/summary\u003e\n        \u003cp\u003eIl produttore indica che consente di collegare fino a otto alimentatori in un unico sistema.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCon quali apparecchi è compatibile?\u003c\/summary\u003e\n        \u003cp\u003eÈ pensato per il LogiCO2 Safety System. La documentazione mostra esempi con Central Unit Mk9, sensori CO2 Mk9, CO2 Mk90 e sensore O2 Mk9.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCome faccio a sapere se il modulo è correttamente alimentato?\u003c\/summary\u003e\n        \u003cp\u003eL’apparecchiatura dispone di due LED verdi. Quello superiore indica l’alimentazione sul cavo sinistro e quello inferiore sul destro. Entrambi devono essere accesi per un corretto funzionamento.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-downloads\"\u003e\n      \u003ch2\u003eScaricabili\u003c\/h2\u003e\n      \u003cdiv class=\"ibpb-download-grid\"\u003e\n        \u003ca class=\"ibpb-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/Power_Barrier_AddonKIT_0482_en_db_LogiCO2_r4_0.pdf?v=1775122685\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eScheda tecnica Power Barrier 0482\u003c\/a\u003e\n        \u003ca class=\"ibpb-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/Logico2_stromforbrukning.pdf?v=1775122684\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTabella dei consumi LogiCO2\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-related\"\u003e\n      \u003ch2\u003ePotrebbe interessarti anche\u003c\/h2\u003e\n      \u003cdiv class=\"ibpb-related-grid\"\u003e\n        \u003ca class=\"ibpb-btn\" href=\"\/it-eea\/collections\/logico2\"\u003eProdotti LogiCO2\u003c\/a\u003e\n        \u003ca class=\"ibpb-btn\" href=\"\/it-eea\/pages\/servicio-tecnico\"\u003eConsulenza e installazione tecnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57249172848988,"sku":"LG028","price":226.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/powerbarrier-cab-logico2_4fa53e5e-01c2-4255-928b-683afa722d7d.webp?v=1775123735","url":"https:\/\/installbeer.com\/it-eea\/products\/kit-aggiuntivo-power-barrier-logico2-sistema-sicurezza-co2","provider":"Install Beer","version":"1.0","type":"link"}