{"product_id":"kit-adicional-de-valvula-de-seguridad-y-smb-logico2-para-sistemas-co2","title":"Kit aggiuntivo di valvola di sicurezza e SMB LogiCO2 per sistemi CO2","description":"\u003csection class=\"ibsmb-product ibsmb-0476\" data-brand=\"LogiCO2\" data-model=\"SMB Safety Valve Add-on KIT\"\u003e\n  \u003cstyle\u003e\n    .ibsmb-product{\n      --ibsmb-max:1120px;\n      --ibsmb-text:#1f2328;\n      --ibsmb-muted:#5b6573;\n      --ibsmb-line:#e6e8eb;\n      --ibsmb-soft:#f7f8fa;\n      --ibsmb-soft2:#f2f4f6;\n      --ibsmb-accent:#111111;\n      --ibsmb-radius:18px;\n      --ibsmb-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibsmb-content-size:16px;\n      --ibsmb-content-lh:1.68;\n      --ibsmb-h2-size:28px;\n      --ibsmb-h3-size:20px;\n      color:var(--ibsmb-text);\n      font-size:var(--ibsmb-content-size);\n      line-height:var(--ibsmb-content-lh);\n    }\n    .ibsmb-product *{box-sizing:border-box}\n    .ibsmb-wrap{max-width:var(--ibsmb-max);margin:0 auto;padding:4px 0 36px}\n    .ibsmb-hero,.ibsmb-block,.ibsmb-specs,.ibsmb-faq,.ibsmb-downloads,.ibsmb-related{\n      background:#fff;border:1px solid var(--ibsmb-line);border-radius:var(--ibsmb-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibsmb-shadow)\n    }\n    .ibsmb-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibsmb-line);\n      border-radius:999px;background:var(--ibsmb-soft);color:var(--ibsmb-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibsmb-product h2{\n      font-size:var(--ibsmb-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibsmb-accent)\n    }\n    .ibsmb-product h3{\n      font-size:var(--ibsmb-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibsmb-accent)\n    }\n    .ibsmb-product p{\n      margin:0 0 14px;\n      font-size:var(--ibsmb-content-size);\n      line-height:var(--ibsmb-content-lh)\n    }\n    .ibsmb-product p:last-child{margin-bottom:0}\n    .ibsmb-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibsmb-soft);border:1px solid var(--ibsmb-line)\n    }\n    .ibsmb-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibsmb-card{\n      padding:16px;border:1px solid var(--ibsmb-line);border-radius:16px;background:var(--ibsmb-soft)\n    }\n    .ibsmb-card strong{display:block;margin-bottom:6px;color:var(--ibsmb-accent)}\n    .ibsmb-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibsmb-accent);\n      background:var(--ibsmb-soft2);border-radius:12px\n    }\n    .ibsmb-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibsmb-list-grid li{\n      padding:16px;border:1px solid var(--ibsmb-line);border-radius:16px;background:#fff\n    }\n    .ibsmb-list-grid li strong{display:block;margin-bottom:6px}\n    .ibsmb-bullets{margin:0;padding-left:18px}\n    .ibsmb-bullets li{margin:0 0 10px}\n    .ibsmb-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibsmb-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibsmb-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibsmb-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibsmb-accent)\n    }\n    .ibsmb-table thead th{\n      background:var(--ibsmb-soft2);color:var(--ibsmb-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibsmb-line);font-size:15px\n    }\n    .ibsmb-table tbody th,.ibsmb-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibsmb-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibsmb-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibsmb-accent)}\n    .ibsmb-table tbody tr:last-child th,.ibsmb-table tbody tr:last-child td{border-bottom:none}\n    .ibsmb-download-grid,.ibsmb-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibsmb-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibsmb-accent);text-decoration:none;color:var(--ibsmb-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibsmb-btn:hover{transform:translateY(-1px);box-shadow:var(--ibsmb-shadow)}\n    .ibsmb-faq details{\n      border:1px solid var(--ibsmb-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibsmb-faq details:last-child{margin-bottom:0}\n    .ibsmb-faq summary{cursor:pointer;font-weight:700;color:var(--ibsmb-accent)}\n    .ibsmb-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibsmb-cards,.ibsmb-list-grid,.ibsmb-download-grid,.ibsmb-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibsmb-product{\n        --ibsmb-content-size:15px;\n        --ibsmb-h2-size:23px;\n        --ibsmb-h3-size:18px;\n      }\n      .ibsmb-hero,.ibsmb-block,.ibsmb-specs,.ibsmb-faq,.ibsmb-downloads,.ibsmb-related{\n        padding:18px;border-radius:16px\n      }\n      .ibsmb-table{min-width:100%;border:0}\n      .ibsmb-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibsmb-table,.ibsmb-table tbody,.ibsmb-table tr,.ibsmb-table th,.ibsmb-table td{\n        display:block;width:100%\n      }\n      .ibsmb-table tr{\n        border:1px solid var(--ibsmb-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibsmb-table tbody th{\n        background:var(--ibsmb-soft2);border-bottom:1px solid var(--ibsmb-line)\n      }\n      .ibsmb-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibsmb-wrap\"\u003e\n    \u003cdiv class=\"ibsmb-hero\"\u003e\n      \u003cdiv class=\"ibsmb-kicker\"\u003eSicurezza CO2 · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eValvola di sicurezza SMB LogiCO2 per interrompere il CO2 in caso di perdita\u003c\/h2\u003e\n      \u003cp class=\"ibsmb-snippet\"\u003e\u003cstrong\u003eIl kit aggiuntivo di valvola di sicurezza e SMB LogiCO2 interrompe automaticamente la distribuzione di CO2 quando un sensore Mk9 o Mk90 rileva una concentrazione elevata, contribuendo a limitare la fuga fin dall’inizio della linea gas.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eCosa offre questo prodotto\u003c\/h2\u003e\n      \u003cp\u003eQuesto accessorio è pensato per aggiungere una misura attiva di sicurezza al sistema LogiCO2: non solo rilevare una fuga, ma anche chiudere il passaggio del gas quando si verifica un allarme.\u003c\/p\u003e\n      \u003cp\u003eIl suo valore tecnico sta nel fatto che la valvola magnetica agisce sulla distribuzione del CO2 e lavora in modalità fail-safe. Ciò significa che, se si perde l’alimentazione, la valvola si chiude.\u003c\/p\u003e\n      \u003cp\u003eIn un’installazione reale, questo aiuta a ridurre il rischio di continuare ad alimentare una fuga dalla bombola o dal serbatoio verso la linea di distribuzione.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eDati chiave\u003c\/h2\u003e\n      \u003cdiv class=\"ibsmb-cards\"\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003eCodice produttore\u003c\/strong\u003e\n          0476\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG010\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003eCompatibilità\u003c\/strong\u003e\n          Sistemi CO2 LogiCO2 Mk9 e Mk90\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003ePressione di esercizio\u003c\/strong\u003e\n          0,15 a 30 bar\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003eConnessione filettata\u003c\/strong\u003e\n          1\/4”-18NPT\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003eModalità di sicurezza\u003c\/strong\u003e\n          Fail-safe, chiusura in assenza di alimentazione\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"ibsmb-note\"\u003e\n        \u003cstrong\u003eNota importante:\u003c\/strong\u003e questo prodotto non sostituisce il rivelatore né l’unità centrale. È un accessorio complementare che agisce sulla linea del gas quando il sistema LogiCO2 rileva una fuga.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eCaratteristiche principali\u003c\/h2\u003e\n      \u003cul class=\"ibsmb-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eInterruzione automatica del CO2\u003c\/strong\u003e Chiude la distribuzione del gas quando il sensore rileva un’elevata concentrazione di CO2.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eValvola fail-safe\u003c\/strong\u003e Si chiude in caso di perdita di alimentazione, aggiungendo un livello di sicurezza passiva.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompatibile con Mk9 e Mk90\u003c\/strong\u003e È progettato come accessorio per i sistemi di sicurezza CO2 LogiCO2 Mk9 e Mk90.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUscita segnale blu RJ45\u003c\/strong\u003e La scatola elettronica si collega al lato blu di segnalazione d’allarme del sensore.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eImpostazione di fabbrica in allarme alto\u003c\/strong\u003e È fornita configurata per chiudere in allarme alto, con possibilità di modificarla su allarme basso\/preallarme tramite ponticello.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicatore visivo di stato\u003c\/strong\u003e Integra una spia rossa che indica valvola aperta.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFormato compatto\u003c\/strong\u003e Scatola elettronica da 78 x 78 x 37 mm, facile da integrare nelle sale tecniche.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eInstallazione vicino alla bombola\u003c\/strong\u003e Il produttore raccomanda di montarla il prima possibile nella catena di distribuzione, vicino al serbatoio di CO2.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-specs\"\u003e\n      \u003ch2\u003eSpecifiche tecniche\u003c\/h2\u003e\n      \u003cdiv class=\"ibsmb-table-wrap\"\u003e\n        \u003ctable class=\"ibsmb-table\"\u003e\n          \u003ccaption\u003eSpecifiche tecniche confermate del kit aggiuntivo con valvola di sicurezza e SMB LogiCO2\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParametro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confermato\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarca\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModello\u003c\/th\u003e\n              \u003ctd\u003eSMB Safety Valve Add-on KIT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG010\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ codice articolo del produttore\u003c\/th\u003e\n              \u003ctd\u003e0476\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTipo di apparecchiatura\u003c\/th\u003e\n              \u003ctd\u003eScatola di modo sicuro con valvola di sicurezza per sistema di sicurezza CO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCompatibilità\u003c\/th\u003e\n              \u003ctd\u003eSistema di sicurezza CO2 LogiCO2 Mk9 e Mk90\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFunzione\u003c\/th\u003e\n              \u003ctd\u003eChiudere la distribuzione di gas CO2 in caso di perdita\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTipo di valvola\u003c\/th\u003e\n              \u003ctd\u003eValvola magnetica di chiusura di sicurezza\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModalità fail-safe\u003c\/th\u003e\n              \u003ctd\u003eSì, la valvola si chiude in caso di perdita di alimentazione\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFuente de alimentación\u003c\/th\u003e\n              \u003ctd\u003eAttraverso il sensore di CO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eRelés\u003c\/th\u003e\n              \u003ctd\u003e1A \/ 24 V CA\/CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMateriale\u003c\/th\u003e\n              \u003ctd\u003ePC\/ABS\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePressione di funzionamento\u003c\/th\u003e\n              \u003ctd\u003e0,15–30 bar \/ 2,2–435 psi\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePressione di scoppio\u003c\/th\u003e\n              \u003ctd\u003e\u003e150 bar \/ 2175 Psi\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConnessione filettata\u003c\/th\u003e\n              \u003ctd\u003e1\/4”-18NPT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensioni\u003c\/th\u003e\n              \u003ctd\u003e78 x 78 x 37 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtezione contro la penetrazione\u003c\/th\u003e\n              \u003ctd\u003eIP55\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCablaggio\u003c\/th\u003e\n              \u003ctd\u003eCavo Cat. 5 da 1 metro dalla scatola elettronica con connettore RJ45 blu\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eImpostazione di fabbrica\u003c\/th\u003e\n              \u003ctd\u003eChiusura per allarme alto\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eImpostazione configurabile\u003c\/th\u003e\n              \u003ctd\u003ePuò essere modificato per chiudere in allarme basso\/preallarme\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIndicatore di stato\u003c\/th\u003e\n              \u003ctd\u003eSpia rossa; accesa indica valvola aperta\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eContenuto della fornitura\u003c\/th\u003e\n              \u003ctd\u003eSMB + valvola di intercettazione di sicurezza + cavo da 1 m; la scheda indica anche consegna con sdoppiatore RJ45 1-4 e la pagina ufficiale specifica valvola senza filtro\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eCompatibilità e casi d’uso\u003c\/h2\u003e\n      \u003cp\u003eQuesto kit è pensato per installazioni di CO2 in cui è già presente un sistema LogiCO2 Mk9 o Mk90 e si desidera aggiungere l’interruzione automatica del gas in caso di fuga.\u003c\/p\u003e\n      \u003cp\u003eÈ adatto per strutture ricettive, cantine, birrifici, celle frigorifere, sale tecniche e qualsiasi installazione in cui la bombola o il serbatoio di CO2 alimenti una rete di distribuzione e sia opportuno interrompere la fornitura in caso di allarme.\u003c\/p\u003e\n      \u003cp\u003eHa senso anche quando il progetto include centrale, sensori, sirena\/lampada e altri accessori di sicurezza all’interno dell’architettura LogiCO2.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eInstallazione e considerazioni prima dell’acquisto\u003c\/h2\u003e\n      \u003cul class=\"ibsmb-bullets\"\u003e\n        \u003cli\u003eLa valvola magnetica deve essere installata il prima possibile nella catena di distribuzione del gas, vicino al serbatoio o alla bombola di CO2.\u003c\/li\u003e\n        \u003cli\u003eLa scatola elettronica deve essere montata in un luogo meccanicamente protetto.\u003c\/li\u003e\n        \u003cli\u003eIl collegamento avviene tramite il connettore RJ45 blu sul lato di uscita di segnalazione di allarme blu del sensore Mk9 o Mk90.\u003c\/li\u003e\n        \u003cli\u003ePrima dell’acquisto, verifica il filetto dell’installazione: 1\/4”-18NPT.\u003c\/li\u003e\n        \u003cli\u003eVerifica anche la pressione di lavoro reale del circuito, che deve essere compresa tra 0,15 e 30 bar.\u003c\/li\u003e\n        \u003cli\u003eSe il progetto dell’impianto è grande o ha molti accessori, è opportuno verificare il consumo totale del sistema e la distribuzione dell’alimentazione all’interno dell’architettura LogiCO2.\u003c\/li\u003e\n        \u003cli\u003eIn quanto apparecchiatura di sicurezza, l’installazione e la messa in servizio devono essere eseguite con criterio tecnico e con una verifica funzionale finale.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eManutenzione e uso consigliato\u003c\/h2\u003e\n      \u003cp\u003eIl produttore raccomanda un controllo annuale delle funzioni. Per verificare la valvola, il testimone deve essere acceso, il che indica valvola aperta.\u003c\/p\u003e\n      \u003cp\u003eLa prova si effettua premendo il pulsante di test sulla scatola di connessione SMB: la spia deve spegnersi e la valvola deve emettere un clic netto. Dopo qualsiasi intervento sul sistema, è opportuno ripetere questa verifica.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-faq\"\u003e\n      \u003ch2\u003eDomande frequenti\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eA cosa serve esattamente la SMB con valvola di sicurezza?\u003c\/summary\u003e\n        \u003cp\u003eServe per interrompere automaticamente la distribuzione di CO2 quando il sistema LogiCO2 rileva una perdita o un’alta concentrazione.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eÈ compatibile con qualsiasi rivelatore?\u003c\/summary\u003e\n        \u003cp\u003eNo. È progettata come accessorio per i sistemi LogiCO2 di CO2 Mk9 e Mk90.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDove deve essere installata la valvola?\u003c\/summary\u003e\n        \u003cp\u003eDeve essere installata il più vicino possibile al serbatoio o alla bombola di CO2, all’inizio della catena di distribuzione.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCosa succede se viene a mancare l’alimentazione elettrica?\u003c\/summary\u003e\n        \u003cp\u003eLa valvola è fail-safe, quindi si chiude in caso di perdita di alimentazione.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eViene configurato per allarme alto o basso?\u003c\/summary\u003e\n        \u003cp\u003eDi fabbrica è configurata per chiudere in allarme alto, anche se può essere regolata per intervenire in allarme basso o preallarme.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCome si verifica che funzioni correttamente?\u003c\/summary\u003e\n        \u003cp\u003eIl produttore raccomanda una prova annuale: con la spia accesa, premi il pulsante di test sulla SMB; la spia deve spegnersi e si deve sentire un clic della valvola.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-downloads\"\u003e\n      \u003ch2\u003eScaricabili\u003c\/h2\u003e\n      \u003cdiv class=\"ibsmb-download-grid\"\u003e\n        \u003ca class=\"ibsmb-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/SMB_sov_AddonKIT_0476_es.pdf?v=1776182868\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eScheda tecnica SMB e valvola di sicurezza\u003c\/a\u003e\n        \u003ca class=\"ibsmb-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/smb_sv_0476_es_in_hfe1262.pdf?v=1776182868\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManuale di installazione SMB e valvola di sicurezza\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-related\"\u003e\n      \u003ch2\u003ePotrebbe interessarti anche\u003c\/h2\u003e\n      \u003cdiv class=\"ibsmb-related-grid\"\u003e\n        \u003ca class=\"ibsmb-btn\" href=\"\/it-eea\/collections\/logico2-detectores-co2-seguridad-industrial-horeca\"\u003eProdotti LogiCO2\u003c\/a\u003e\n        \u003ca class=\"ibsmb-btn\" href=\"\/it-eea\/pages\/servicio-tecnico\"\u003eConsulenza e installazione tecnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57365627044188,"sku":"LG010","price":378.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/0476-smb-safetyvalve-logico2.webp?v=1776183246","url":"https:\/\/installbeer.com\/it-eea\/products\/kit-aggiuntivo-di-valvola-di-sicurezza-e-smb-logico2-per-sistemi-co2","provider":"Install Beer","version":"1.0","type":"link"}