{"product_id":"kit-4a-unidad-central-co2-logico2-mk9","title":"Kit aggiuntivo di unità centrale A4 di sensori di CO2 LogiCO2 Mk9","description":"\u003csection class=\"iblgmk9-product iblgmk9-central\" data-brand=\"LogiCO2\" data-model=\"Mk9 Central Unit Add-on KIT\"\u003e\n  \u003cstyle\u003e\n    .iblgmk9-product{\n      --ib-max:1120px;\n      --ib-text:#1f2328;\n      --ib-muted:#5b6573;\n      --ib-line:#e6e8eb;\n      --ib-soft:#f7f8fa;\n      --ib-soft2:#f2f4f6;\n      --ib-accent:#111111;\n      --ib-radius:18px;\n      --ib-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ib-content-size:16px;\n      --ib-content-lh:1.68;\n      --ib-h2-size:28px;\n      --ib-h3-size:20px;\n      color:var(--ib-text);\n      font-size:var(--ib-content-size);\n      line-height:var(--ib-content-lh);\n    }\n    .iblgmk9-product *{box-sizing:border-box}\n    .iblgmk9-wrap{max-width:var(--ib-max);margin:0 auto;padding:4px 0 36px}\n    .iblgmk9-hero,.iblgmk9-block,.iblgmk9-specs,.iblgmk9-faq,.iblgmk9-downloads,.iblgmk9-related{\n      background:#fff;border:1px solid var(--ib-line);border-radius:var(--ib-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ib-shadow)\n    }\n    .iblgmk9-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ib-line);\n      border-radius:999px;background:var(--ib-soft);color:var(--ib-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblgmk9-product h2{\n      font-size:var(--ib-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ib-accent)\n    }\n    .iblgmk9-product h3{\n      font-size:var(--ib-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ib-accent)\n    }\n    .iblgmk9-product p{margin:0 0 14px;font-size:var(--ib-content-size);line-height:var(--ib-content-lh)}\n    .iblgmk9-product p:last-child{margin-bottom:0}\n    .iblgmk9-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ib-soft);border:1px solid var(--ib-line)\n    }\n    .iblgmk9-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblgmk9-card{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:var(--ib-soft)\n    }\n    .iblgmk9-card strong{display:block;margin-bottom:6px;color:var(--ib-accent)}\n    .iblgmk9-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ib-accent);\n      background:var(--ib-soft2);border-radius:12px\n    }\n    .iblgmk9-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblgmk9-list-grid li{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:#fff\n    }\n    .iblgmk9-list-grid li strong{display:block;margin-bottom:6px}\n    .iblgmk9-bullets{margin:0;padding-left:18px}\n    .iblgmk9-bullets li{margin:0 0 10px}\n    .iblgmk9-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblgmk9-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ib-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblgmk9-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ib-accent)\n    }\n    .iblgmk9-table thead th{\n      background:var(--ib-soft2);color:var(--ib-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);font-size:15px\n    }\n    .iblgmk9-table tbody th,.iblgmk9-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblgmk9-table tbody th{width:32%;background:#fcfcfd;font-weight:700;color:var(--ib-accent)}\n    .iblgmk9-table tbody tr:last-child th,.iblgmk9-table tbody tr:last-child td{border-bottom:none}\n    .iblgmk9-download-grid,.iblgmk9-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblgmk9-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ib-accent);text-decoration:none;color:var(--ib-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblgmk9-btn:hover{transform:translateY(-1px);box-shadow:var(--ib-shadow)}\n    .iblgmk9-faq details{\n      border:1px solid var(--ib-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblgmk9-faq details:last-child{margin-bottom:0}\n    .iblgmk9-faq summary{cursor:pointer;font-weight:700;color:var(--ib-accent)}\n    .iblgmk9-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblgmk9-cards,.iblgmk9-list-grid,.iblgmk9-download-grid,.iblgmk9-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblgmk9-product{\n        --ib-content-size:15px;\n        --ib-h2-size:23px;\n        --ib-h3-size:18px;\n      }\n      .iblgmk9-hero,.iblgmk9-block,.iblgmk9-specs,.iblgmk9-faq,.iblgmk9-downloads,.iblgmk9-related{\n        padding:18px;border-radius:16px\n      }\n      .iblgmk9-table{min-width:100%;border:0}\n      .iblgmk9-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblgmk9-table,.iblgmk9-table tbody,.iblgmk9-table tr,.iblgmk9-table th,.iblgmk9-table td{\n        display:block;width:100%\n      }\n      .iblgmk9-table tr{\n        border:1px solid var(--ib-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblgmk9-table tbody th{\n        background:var(--ib-soft2);border-bottom:1px solid var(--ib-line)\n      }\n      .iblgmk9-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblgmk9-wrap\"\u003e\n    \u003cdiv class=\"iblgmk9-hero\"\u003e\n      \u003cdiv class=\"iblgmk9-kicker\"\u003eSeguridad CO2 · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eUnità centrale CO2 LogiCO2 Mk9 per controllare e supervisionare il sistema\u003c\/h2\u003e\n      \u003cp class=\"iblgmk9-snippet\"\u003e\u003cstrong\u003eIl kit 4A di unità centrale di CO2 LogiCO2 Mk9 è la centrale di controllo del sistema di sicurezza CO2: riceve i dati dai sensori, visualizza allarmi, TWA e temperatura e consente di supervisionare il funzionamento generale dell’impianto.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eQué aporta este producto\u003c\/h2\u003e\n      \u003cp\u003eQuesta unità centrale è pensata per impianti LogiCO2 in cui esistono già sensori o dove si intende ampliare un sistema di sicurezza CO2. La sua funzione non è rilevare da sola, ma centralizzare le informazioni dei sensori, mostrare lo stato del sistema e gestire la segnalazione di allarme ed errore.\u003c\/p\u003e\n      \u003cp\u003eÈ particolarmente indicato per strutture ricettive, sale tecniche, cantine, birrifici, produttori di bevande e qualsiasi spazio interno in cui la CO2 è utilizzata, stoccata o distribuita e si richiede una supervisione più ordinata rispetto a un singolo sensore autonomo isolato.\u003c\/p\u003e\n      \u003cp\u003eDal punto di vista operativo, offre lettura centralizzata, controllo visivo del sistema, avviso acustico, pulsante di silenziamento e reset, e identificazione del sensore che sta generando la lettura o l’allarme.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eDati chiave\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-cards\"\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          0328\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG005\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eTipo di apparecchiatura\u003c\/strong\u003e\n          Unità centrale per sistema di sicurezza CO2\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eComunicazione\u003c\/strong\u003e\n          RS485 Modbus\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eDisplay\u003c\/strong\u003e\n          LCD a matrice di punti 128x64\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eAlimentazione\u003c\/strong\u003e\n          12-24 V CC\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblgmk9-note\"\u003e\n        \u003cstrong\u003eImportante:\u003c\/strong\u003e la scheda specifica del kit 0328 indica il monitoraggio fino a 8 sensori, mentre la documentazione generale del sistema Mk9\/Mk90 mostra configurazioni fino a 12 sensori. Se il tuo progetto supera 8 sensori, è opportuno confermare la configurazione esatta prima dell’acquisto.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eCaratteristiche principali\u003c\/h2\u003e\n      \u003cul class=\"iblgmk9-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSupervisione centralizzata\u003c\/strong\u003e Visualizza risultati, allarmi e anomalie dei sensori collegati in un unico punto di controllo.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eControllo del sistema\u003c\/strong\u003e L’unità centrale supervisiona il funzionamento generale e visualizza gli errori quando viene rilevato un guasto.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLettura chiara sul display\u003c\/strong\u003e Visualizza CO2, TWA e temperatura; se sono presenti più sensori, identifica da quale sensore proviene ciascuna lettura.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePulsante di silenziamento e reset\u003c\/strong\u003e Consente di silenziare l’avvisatore acustico e resettare l’allarme una volta risolta l’anomalia.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicatori LED di stato\u003c\/strong\u003e LED verde di funzionamento, LED giallo di errore e LED rosso di allarme o avviso.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompatibilità con sensori LogiCO2\u003c\/strong\u003e Progettata per collegare sensori fissi LogiCO2; la pagina ufficiale indica anche la compatibilità con sensori MkVII meno recenti.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eComunicazione industriale\u003c\/strong\u003e Utilizza RS485 Modbus, un’architettura abituale nei sistemi di supervisione tecnica.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMultilingue\u003c\/strong\u003e La documentazione del prodotto indica 19 lingue e la pagina ufficiale elenca numerose lingue, tra cui l’italiano.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-specs\"\u003e\n      \u003ch2\u003eSpecifiche tecniche\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-table-wrap\"\u003e\n        \u003ctable class=\"iblgmk9-table\"\u003e\n          \u003ccaption\u003eSpecifiche tecniche confermate del kit 4A di unità centrale CO2 LogiCO2 Mk9\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarca\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModello\u003c\/th\u003e\n              \u003ctd\u003eMk9 Central Unit Add-on KIT \/ Kit unità centrale di CO2 Mk9 4A\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG005\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e0328\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTipo di apparecchiatura\u003c\/th\u003e\n              \u003ctd\u003eUnità centrale per sistema di sicurezza CO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFunzione principale\u003c\/th\u003e\n              \u003ctd\u003eSupervisionare i sensori LogiCO2, visualizzare le letture e gli allarmi e controllare il funzionamento del sistema\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCapacità dichiarata nella scheda del kit 0328\u003c\/th\u003e\n              \u003ctd\u003eHasta 8 sensores\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCapacità indicata nella documentazione generale Mk9\/Mk90\u003c\/th\u003e\n              \u003ctd\u003eConfigurazioni da 1 a 12 sensori nel manuale e fino a 12 sensori nella pagina generale del prodotto\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAlimentazione\u003c\/th\u003e\n              \u003ctd\u003e12-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAssorbimento di corrente\u003c\/th\u003e\n              \u003ctd\u003e35 mA secondo scheda 0328\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eComunicazione\u003c\/th\u003e\n              \u003ctd\u003eRS485, Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n              \u003ctd\u003eLCD a matrice di punti 128x64\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIntensità del segnale acustico\u003c\/th\u003e\n              \u003ctd\u003e70 dB (1 m) max.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura ambiente\u003c\/th\u003e\n              \u003ctd\u003e0-40 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUmidità\u003c\/th\u003e\n              \u003ctd\u003e0–90 % senza condensa\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtección contra penetración\u003c\/th\u003e\n              \u003ctd\u003eIP54 secondo scheda 0328\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensioni\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePeso\u003c\/th\u003e\n              \u003ctd\u003eDato non fornito\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConnessioni\u003c\/th\u003e\n              \u003ctd\u003eCablaggio RJ45 per alimentazione, comunicazione e segnalazione\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIndicatori\u003c\/th\u003e\n              \u003ctd\u003eLED verde di accensione, LED giallo di errore e LED rosso di allarme\/allerta\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eValori visualizzati\u003c\/th\u003e\n              \u003ctd\u003eCO2, TWA (ppm) e temperatura; identifica inoltre il sensore che genera la lettura o l’allarme\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePulsante frontale\u003c\/th\u003e\n              \u003ctd\u003eSilenziamento, reset e test\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLingue\u003c\/th\u003e\n              \u003ctd\u003eMultilingue; la scheda 0328 indica 19 lingue\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCompatibilità\u003c\/th\u003e\n              \u003ctd\u003eSensori LogiCO2 per installazione fissa; la pagina ufficiale indica inoltre compatibilità con sensori MkVII meno recenti\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eContenuto della fornitura\u003c\/th\u003e\n              \u003ctd\u003eUnità centrale di CO2 Mk9, 1 cavo rosso da 5 m, sdoppiatore RJ45 1-2, cartello del sistema di sicurezza CO2 Mk9, manuale\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCertificazioni e conformità\u003c\/th\u003e\n              \u003ctd\u003eCE, prove secondo SS-EN 61000-6-3 e SS-EN 61000-6-2, fabbricato secondo DIN 6653-2, sistema collaudato da TÜV-Rheinland e certificato UL\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eCompatibilità e casi d’uso\u003c\/h2\u003e\n      \u003cp\u003eQuesta unità centrale è pensata per lavorare con sensori fissi LogiCO2 e centralizzare le informazioni di sicurezza in impianti in cui si utilizza CO2. È particolarmente utile in ristorazione, celle, cantine, birrifici, sale tecniche, produttori di bevande e altri spazi interni con distribuzione o stoccaggio di CO2.\u003c\/p\u003e\n      \u003cp\u003eLa sua logica d’uso ha senso quando ci sono più punti di monitoraggio, quando si vuole identificare da quale sensore proviene un allarme o quando si desidera una supervisione più chiara dell’intero sistema.\u003c\/p\u003e\n      \u003cp\u003ePer funzionare necessita di sensori compatibili all’interno dell’ecosistema LogiCO2 e di un’architettura di cablaggio adeguata. La stessa pagina ufficiale del prodotto indica compatibilità con sensori fissi LogiCO2 e anche con sensori MkVII meno recenti.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eInstallazione e considerazioni prima dell’acquisto\u003c\/h2\u003e\n      \u003cul class=\"iblgmk9-bullets\"\u003e\n        \u003cli\u003eVerificare prima quanti sensori gestirà effettivamente il sistema, perché la scheda 0328 e la documentazione generale non coincidono nella capacità massima dichiarata.\u003c\/li\u003e\n        \u003cli\u003eVerificare che l’impianto disponga di sensori LogiCO2 compatibili e di una topologia di cablaggio adeguata.\u003c\/li\u003e\n        \u003cli\u003eValuta il posizionamento dell’unità centrale in una zona visibile, accessibile e protetta per consultazione, silenziamento, prova e riarmo.\u003c\/li\u003e\n        \u003cli\u003eVerifica l’alimentazione disponibile: l’unità funziona a 12-24 V CC.\u003c\/li\u003e\n        \u003cli\u003eSe il sistema deve visualizzare più sensori, assicurarsi di configurare correttamente il numero di sensori collegati secondo il manuale.\u003c\/li\u003e\n        \u003cli\u003ePianificare anche la segnalazione di allarme, le lampade o le sirene associate all’intero sistema, non solo all’unità centrale.\u003c\/li\u003e\n        \u003cli\u003eEssendo un elemento di sicurezza, l’installazione e la messa in servizio devono essere eseguite con criterio tecnico e con verifica funzionale del sistema.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eManutenzione e uso consigliato\u003c\/h2\u003e\n      \u003cp\u003eL’unità centrale non sostituisce la manutenzione del sistema: è opportuno controllare periodicamente lo stato di cavi, connettori, LED, avvisatore acustico e display, oltre a verificare che la centrale riceva e visualizzi correttamente le informazioni di ogni sensore collegato.\u003c\/p\u003e\n      \u003cp\u003eIl manuale raccomanda di testare l’allarme per verificare che la comunicazione, le spie di avvertimento e gli indicatori acustici funzionino correttamente. In caso di allarme, l’avvisatore acustico può essere silenziato brevemente e il ripristino completo deve essere effettuato quando l’anomalia è stata risolta.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-faq\"\u003e\n      \u003ch2\u003eDomande frequenti\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCosa fa esattamente questa unità centrale Mk9?\u003c\/summary\u003e\n        \u003cp\u003eCentralizza le informazioni del sistema di sicurezza CO2, visualizza le letture e gli allarmi dei sensori, controlla il funzionamento del sistema e permette di silenziare o resettare l’allarme.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eInclude sensori di CO2?\u003c\/summary\u003e\n        \u003cp\u003eNo. Questo kit corrisponde all’unità centrale e ai suoi accessori base di collegamento e segnalazione. I sensori sono forniti separatamente.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eQuanti sensori può monitorare?\u003c\/summary\u003e\n        \u003cp\u003eLa scheda dell’articolo 0328 indica fino a 8 sensori. La documentazione generale Mk9\/Mk90 mostra configurazioni fino a 12 sensori. In caso di ampliamenti è opportuno confermare la configurazione esatta del sistema prima dell’acquisto.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCosa include il kit 0328?\u003c\/summary\u003e\n        \u003cp\u003eInclude l’unità centrale Mk9, un cavo rosso RJ45 da 5 metri, uno sdoppiatore RJ45 1-2, il cartello del sistema di sicurezza CO2 Mk9 e la relativa documentazione.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eÈ possibile silenziare un allarme dall’unità centrale?\u003c\/summary\u003e\n        \u003cp\u003eSì. L’unità dispone di un pulsante frontale di silenziamento e reset. Consente inoltre di testare il sistema direttamente dall’apparecchiatura.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCon quali sensori è compatibile?\u003c\/summary\u003e\n        \u003cp\u003eÈ pensata per sensori fissi LogiCO2. La pagina ufficiale del prodotto indica anche la compatibilità con i vecchi sensori MkVII.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-downloads\"\u003e\n      \u003ch2\u003eScaricabili\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-download-grid\"\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/KIT_adicional_de_unidad_central_de_CO2.pdf?v=1775035270\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eScheda tecnica LogiCO2 0328\u003c\/a\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManual Mk9 \/ Mk90\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-related\"\u003e\n      \u003ch2\u003ePotrebbe interessarti anche\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-related-grid\"\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"\/it-eea\/collections\/alarmas-detectores-co2-logico2\"\u003eAlarmas y detectores de CO2 LogiCO2\u003c\/a\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"\/it-eea\/pages\/servicio-tecnico\"\u003eConsulenza e installazione tecnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57238885597532,"sku":"LG005","price":228.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/mk9-central-unit-cab-logico2.webp?v=1775036817","url":"https:\/\/installbeer.com\/it-eea\/products\/kit-4a-unita-centrale-co2-logico2-mk9","provider":"Install Beer","version":"1.0","type":"link"}