{"product_id":"kit-4a-unidad-central-co2-logico2-mk9","title":"Kit adicional de unidad central A4 de sensores de CO2 LogiCO2 Mk9","description":"\u003csection class=\"iblgmk9-product iblgmk9-central\" data-brand=\"LogiCO2\" data-model=\"Mk9 Central Unit Add-on KIT\"\u003e\n  \u003cstyle\u003e\n    .iblgmk9-product{\n      --ib-max:1120px;\n      --ib-text:#1f2328;\n      --ib-muted:#5b6573;\n      --ib-line:#e6e8eb;\n      --ib-soft:#f7f8fa;\n      --ib-soft2:#f2f4f6;\n      --ib-accent:#111111;\n      --ib-radius:18px;\n      --ib-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ib-content-size:16px;\n      --ib-content-lh:1.68;\n      --ib-h2-size:28px;\n      --ib-h3-size:20px;\n      color:var(--ib-text);\n      font-size:var(--ib-content-size);\n      line-height:var(--ib-content-lh);\n    }\n    .iblgmk9-product *{box-sizing:border-box}\n    .iblgmk9-wrap{max-width:var(--ib-max);margin:0 auto;padding:4px 0 36px}\n    .iblgmk9-hero,.iblgmk9-block,.iblgmk9-specs,.iblgmk9-faq,.iblgmk9-downloads,.iblgmk9-related{\n      background:#fff;border:1px solid var(--ib-line);border-radius:var(--ib-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ib-shadow)\n    }\n    .iblgmk9-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ib-line);\n      border-radius:999px;background:var(--ib-soft);color:var(--ib-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblgmk9-product h2{\n      font-size:var(--ib-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ib-accent)\n    }\n    .iblgmk9-product h3{\n      font-size:var(--ib-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ib-accent)\n    }\n    .iblgmk9-product p{margin:0 0 14px;font-size:var(--ib-content-size);line-height:var(--ib-content-lh)}\n    .iblgmk9-product p:last-child{margin-bottom:0}\n    .iblgmk9-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ib-soft);border:1px solid var(--ib-line)\n    }\n    .iblgmk9-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblgmk9-card{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:var(--ib-soft)\n    }\n    .iblgmk9-card strong{display:block;margin-bottom:6px;color:var(--ib-accent)}\n    .iblgmk9-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ib-accent);\n      background:var(--ib-soft2);border-radius:12px\n    }\n    .iblgmk9-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblgmk9-list-grid li{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:#fff\n    }\n    .iblgmk9-list-grid li strong{display:block;margin-bottom:6px}\n    .iblgmk9-bullets{margin:0;padding-left:18px}\n    .iblgmk9-bullets li{margin:0 0 10px}\n    .iblgmk9-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblgmk9-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ib-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblgmk9-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ib-accent)\n    }\n    .iblgmk9-table thead th{\n      background:var(--ib-soft2);color:var(--ib-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);font-size:15px\n    }\n    .iblgmk9-table tbody th,.iblgmk9-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblgmk9-table tbody th{width:32%;background:#fcfcfd;font-weight:700;color:var(--ib-accent)}\n    .iblgmk9-table tbody tr:last-child th,.iblgmk9-table tbody tr:last-child td{border-bottom:none}\n    .iblgmk9-download-grid,.iblgmk9-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblgmk9-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ib-accent);text-decoration:none;color:var(--ib-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblgmk9-btn:hover{transform:translateY(-1px);box-shadow:var(--ib-shadow)}\n    .iblgmk9-faq details{\n      border:1px solid var(--ib-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblgmk9-faq details:last-child{margin-bottom:0}\n    .iblgmk9-faq summary{cursor:pointer;font-weight:700;color:var(--ib-accent)}\n    .iblgmk9-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblgmk9-cards,.iblgmk9-list-grid,.iblgmk9-download-grid,.iblgmk9-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblgmk9-product{\n        --ib-content-size:15px;\n        --ib-h2-size:23px;\n        --ib-h3-size:18px;\n      }\n      .iblgmk9-hero,.iblgmk9-block,.iblgmk9-specs,.iblgmk9-faq,.iblgmk9-downloads,.iblgmk9-related{\n        padding:18px;border-radius:16px\n      }\n      .iblgmk9-table{min-width:100%;border:0}\n      .iblgmk9-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblgmk9-table,.iblgmk9-table tbody,.iblgmk9-table tr,.iblgmk9-table th,.iblgmk9-table td{\n        display:block;width:100%\n      }\n      .iblgmk9-table tr{\n        border:1px solid var(--ib-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblgmk9-table tbody th{\n        background:var(--ib-soft2);border-bottom:1px solid var(--ib-line)\n      }\n      .iblgmk9-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblgmk9-wrap\"\u003e\n    \u003cdiv class=\"iblgmk9-hero\"\u003e\n      \u003cdiv class=\"iblgmk9-kicker\"\u003eSeguridad CO2 · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eUnidad central CO2 LogiCO2 Mk9 para controlar y supervisar el sistema\u003c\/h2\u003e\n      \u003cp class=\"iblgmk9-snippet\"\u003e\u003cstrong\u003eEl kit 4A de unidad central de CO2 LogiCO2 Mk9 es la central de control del sistema de seguridad CO2: recibe datos de los sensores, muestra alarmas, TWA y temperatura, y permite supervisar el funcionamiento general de la instalación.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eQué aporta este producto\u003c\/h2\u003e\n      \u003cp\u003eEsta unidad central está pensada para instalaciones LogiCO2 donde ya existen sensores o donde se va a ampliar un sistema de seguridad CO2. Su función no es detectar por sí sola, sino centralizar la información de los sensores, mostrar el estado del sistema y gestionar la señalización de alarma y error.\u003c\/p\u003e\n      \u003cp\u003eEncaja especialmente en hostelería, salas técnicas, bodegas, cervecerías, productores de bebidas y cualquier espacio interior donde el CO2 se utiliza, se almacena o se distribuye y se requiere una supervisión más ordenada que la de un sensor autónomo aislado.\u003c\/p\u003e\n      \u003cp\u003eDesde el punto de vista operativo, aporta lectura centralizada, control visual del sistema, aviso acústico, botón de silenciamiento y reinicio, e identificación del sensor que está generando la lectura o la alarma.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eDatos clave\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-cards\"\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          0328\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG005\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eTipo de equipo\u003c\/strong\u003e\n          Unidad central de sistema de seguridad CO2\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eComunicación\u003c\/strong\u003e\n          RS485 Modbus\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003ePantalla\u003c\/strong\u003e\n          LCD de matriz de puntos 128x64\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgmk9-card\"\u003e\n          \u003cstrong\u003eAlimentación\u003c\/strong\u003e\n          12-24 V CC\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblgmk9-note\"\u003e\n        \u003cstrong\u003eImportante:\u003c\/strong\u003e la ficha específica del kit 0328 habla de supervisión de hasta 8 sensores, mientras que la documentación general del sistema Mk9\/Mk90 muestra configuraciones de hasta 12 sensores. Si tu proyecto supera 8 sensores, conviene confirmar la configuración exacta antes de comprar.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eCaracterísticas principales\u003c\/h2\u003e\n      \u003cul class=\"iblgmk9-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSupervisión centralizada\u003c\/strong\u003e Muestra resultados, alarmas e incidencias de los sensores conectados en un único punto de control.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eControl del sistema\u003c\/strong\u003e La unidad central supervisa el funcionamiento general y muestra errores cuando se detecta un fallo.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLectura clara en pantalla\u003c\/strong\u003e Visualiza CO2, TWA y temperatura; si hay varios sensores, identifica de cuál proviene cada lectura.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBotón de silenciamiento y reinicio\u003c\/strong\u003e Permite silenciar el avisador acústico y reiniciar la alarma una vez resuelta la incidencia.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicadores LED de estado\u003c\/strong\u003e Led verde de funcionamiento, led amarillo de error y led rojo de alarma o alerta.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompatibilidad con sensores LogiCO2\u003c\/strong\u003e Diseñada para conectar sensores fijos LogiCO2; la página oficial también indica compatibilidad con sensores MkVII antiguos.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eComunicación industrial\u003c\/strong\u003e Usa RS485 Modbus, una arquitectura habitual en sistemas de supervisión técnica.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMultilingüe\u003c\/strong\u003e La documentación del producto indica 19 idiomas y la página oficial enumera múltiples idiomas, incluido español.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-specs\"\u003e\n      \u003ch2\u003eEspecificaciones técnicas\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-table-wrap\"\u003e\n        \u003ctable class=\"iblgmk9-table\"\u003e\n          \u003ccaption\u003eEspecificaciones técnicas confirmadas del kit 4A de unidad central de CO2 LogiCO2 Mk9\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarca\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModelo\u003c\/th\u003e\n              \u003ctd\u003eMk9 Central Unit Add-on KIT \/ Kit de unidad central de CO2 Mk9 4A\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG005\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e0328\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTipo de equipo\u003c\/th\u003e\n              \u003ctd\u003eUnidad central para sistema de seguridad CO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFunción principal\u003c\/th\u003e\n              \u003ctd\u003eSupervisar sensores LogiCO2, mostrar lecturas y alarmas, y controlar el funcionamiento del sistema\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCapacidad declarada en ficha del kit 0328\u003c\/th\u003e\n              \u003ctd\u003eHasta 8 sensores\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCapacidad mostrada en documentación general Mk9\/Mk90\u003c\/th\u003e\n              \u003ctd\u003eConfiguraciones de 1 a 12 sensores en el manual y hasta 12 sensores en la página general del producto\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAlimentación\u003c\/th\u003e\n              \u003ctd\u003e12-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConsumo de corriente\u003c\/th\u003e\n              \u003ctd\u003e35 mA según ficha 0328\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eComunicación\u003c\/th\u003e\n              \u003ctd\u003eRS485, Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePantalla\u003c\/th\u003e\n              \u003ctd\u003eLCD de matriz de puntos 128x64\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIntensidad de señal acústica\u003c\/th\u003e\n              \u003ctd\u003e70 dB (1 m) máx.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura ambiente\u003c\/th\u003e\n              \u003ctd\u003e0-40 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eHumedad\u003c\/th\u003e\n              \u003ctd\u003e0-90 % sin condensación\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtección contra penetración\u003c\/th\u003e\n              \u003ctd\u003eIP54 según ficha 0328\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensiones\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePeso\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConexiones\u003c\/th\u003e\n              \u003ctd\u003eCableado RJ45 para alimentación, comunicación y señalización\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIndicadores\u003c\/th\u003e\n              \u003ctd\u003eLed verde de encendido, led amarillo de error y led rojo de alarma\/alerta\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLecturas mostradas\u003c\/th\u003e\n              \u003ctd\u003eCO2, TWA (ppm) y temperatura; también identifica el sensor que origina la lectura o la alarma\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBotón frontal\u003c\/th\u003e\n              \u003ctd\u003eSilenciamiento, restablecimiento y prueba\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIdiomas\u003c\/th\u003e\n              \u003ctd\u003eMultilingüe; la ficha 0328 indica 19 idiomas\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCompatibilidad\u003c\/th\u003e\n              \u003ctd\u003eSensores LogiCO2 para instalación fija; la página oficial indica además compatibilidad con sensores MkVII antiguos\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eContenido del suministro\u003c\/th\u003e\n              \u003ctd\u003eUnidad central de CO2 Mk9, 1 cable rojo de 5 m, bifurcador RJ45 1-2, letrero del sistema de seguridad Mk9 de CO2, manual\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCertificaciones y cumplimiento\u003c\/th\u003e\n              \u003ctd\u003eCE, ensayos según SS-EN 61000-6-3 y SS-EN 61000-6-2, fabricado conforme a DIN 6653-2, sistema probado por TÜV-Rheinland y certificado por UL\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eCompatibilidad y casos de uso\u003c\/h2\u003e\n      \u003cp\u003eEsta unidad central está pensada para trabajar con sensores fijos LogiCO2 y centralizar la información de seguridad en instalaciones donde se usa CO2. Es especialmente útil en hostelería, cámaras, bodegas, cervecerías, salas técnicas, productores de bebidas y otros espacios interiores con distribución o almacenamiento de CO2.\u003c\/p\u003e\n      \u003cp\u003eSu lógica de uso tiene sentido cuando hay más de un punto de vigilancia, cuando se quiere identificar desde qué sensor llega una alarma o cuando se busca una supervisión más clara del sistema completo.\u003c\/p\u003e\n      \u003cp\u003ePara funcionar necesita sensores compatibles dentro del ecosistema LogiCO2 y una arquitectura de cableado adecuada. La propia página oficial del producto indica compatibilidad con sensores fijos LogiCO2 y también con sensores MkVII antiguos.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eInstalación y consideraciones antes de comprar\u003c\/h2\u003e\n      \u003cul class=\"iblgmk9-bullets\"\u003e\n        \u003cli\u003eRevise primero cuántos sensores va a gestionar realmente el sistema, porque la ficha 0328 y la documentación general no coinciden en la capacidad máxima declarada.\u003c\/li\u003e\n        \u003cli\u003eCompruebe que la instalación dispone de sensores LogiCO2 compatibles y de la topología de cableado adecuada.\u003c\/li\u003e\n        \u003cli\u003eValore la ubicación de la unidad central en una zona visible, accesible y protegida para consulta, silenciamiento, prueba y reinicio.\u003c\/li\u003e\n        \u003cli\u003eConfirme la alimentación disponible: la unidad trabaja a 12-24 V CC.\u003c\/li\u003e\n        \u003cli\u003eSi el sistema debe mostrar varios sensores, asegúrese de configurar correctamente el número de sensores conectados según el manual.\u003c\/li\u003e\n        \u003cli\u003ePlanifique también la señalización de alarma, balizas o sirenas asociadas al sistema completo, no solo la central.\u003c\/li\u003e\n        \u003cli\u003eComo es un elemento de seguridad, la instalación y puesta en marcha deben hacerse con criterio técnico y verificación funcional del sistema.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-block\"\u003e\n      \u003ch2\u003eMantenimiento y uso recomendado\u003c\/h2\u003e\n      \u003cp\u003eLa unidad central no sustituye al mantenimiento del sistema: conviene comprobar periódicamente el estado de los cables, conectores, leds, avisador acústico y pantalla, además de verificar que la central recibe y muestra correctamente la información de cada sensor conectado.\u003c\/p\u003e\n      \u003cp\u003eEl manual recomienda probar la alarma para asegurarse de que la comunicación, las luces de advertencia y los indicadores acústicos funcionan. En caso de alarma, el avisador acústico puede silenciarse brevemente y el reinicio completo debe hacerse cuando la incidencia se haya resuelto.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-faq\"\u003e\n      \u003ch2\u003ePreguntas frecuentes\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Qué hace exactamente esta unidad central Mk9?\u003c\/summary\u003e\n        \u003cp\u003eCentraliza la información del sistema de seguridad CO2, muestra lecturas y alarmas de los sensores, controla el funcionamiento del sistema y permite silenciar o reiniciar la alarma.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Incluye sensores de CO2?\u003c\/summary\u003e\n        \u003cp\u003eNo. Este kit corresponde a la unidad central y sus accesorios básicos de conexión y señalización. Los sensores se suministran por separado.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Cuántos sensores puede supervisar?\u003c\/summary\u003e\n        \u003cp\u003eLa ficha del artículo 0328 indica hasta 8 sensores. La documentación general Mk9\/Mk90 muestra configuraciones de hasta 12 sensores. En ampliaciones conviene confirmar la configuración exacta del sistema antes de comprar.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Qué incluye el kit 0328?\u003c\/summary\u003e\n        \u003cp\u003eIncluye la unidad central Mk9, un cable rojo RJ45 de 5 metros, un bifurcador RJ45 1-2, el letrero del sistema de seguridad Mk9 de CO2 y la documentación correspondiente.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Se puede silenciar una alarma desde la unidad central?\u003c\/summary\u003e\n        \u003cp\u003eSí. La unidad dispone de botón frontal de silenciamiento y reinicio. También permite probar el sistema desde el propio equipo.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Con qué sensores es compatible?\u003c\/summary\u003e\n        \u003cp\u003eEstá pensada para sensores fijos LogiCO2. La página oficial del producto también indica compatibilidad con sensores MkVII antiguos.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-downloads\"\u003e\n      \u003ch2\u003eDescargables\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-download-grid\"\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/KIT_adicional_de_unidad_central_de_CO2.pdf?v=1775035270\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eFicha técnica LogiCO2 0328\u003c\/a\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManual Mk9 \/ Mk90\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgmk9-related\"\u003e\n      \u003ch2\u003eTambién puede interesarte\u003c\/h2\u003e\n      \u003cdiv class=\"iblgmk9-related-grid\"\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"\/es-eea\/collections\/alarmas-detectores-co2-logico2\"\u003eAlarmas y detectores de CO2 LogiCO2\u003c\/a\u003e\n        \u003ca class=\"iblgmk9-btn\" href=\"\/es-eea\/pages\/servicio-tecnico\"\u003eAsesoramiento e instalación técnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57238885597532,"sku":"LG005","price":228.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/mk9-central-unit-cab-logico2.webp?v=1775036817","url":"https:\/\/installbeer.com\/es-eea\/products\/kit-4a-unidad-central-co2-logico2-mk9","provider":"Install Beer","version":"1.0","type":"link"}