{"product_id":"conjunto-sensores-co2-camaras-frigorificas-logico2-mk90","title":"Conjunto de sensores de CO2 para cámaras frigoríficas LogiCO2 Mk90","description":"\u003csection class=\"iblgcr-product iblgcr-3349\" data-brand=\"LogiCO2\" data-model=\"CO2 Cold room Mk90 Detector Base SET\"\u003e\n  \u003cstyle\u003e\n    .iblgcr-product{\n      --ib-max:1120px;\n      --ib-text:#1f2328;\n      --ib-muted:#5b6573;\n      --ib-line:#e6e8eb;\n      --ib-soft:#f7f8fa;\n      --ib-soft2:#f2f4f6;\n      --ib-accent:#111111;\n      --ib-radius:18px;\n      --ib-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ib-content-size:16px;\n      --ib-content-lh:1.68;\n      --ib-h2-size:28px;\n      --ib-h3-size:20px;\n      color:var(--ib-text);\n      font-size:var(--ib-content-size);\n      line-height:var(--ib-content-lh);\n    }\n    .iblgcr-product *{box-sizing:border-box}\n    .iblgcr-wrap{max-width:var(--ib-max);margin:0 auto;padding:4px 0 36px}\n    .iblgcr-hero,.iblgcr-block,.iblgcr-specs,.iblgcr-faq,.iblgcr-downloads,.iblgcr-related{\n      background:#fff;border:1px solid var(--ib-line);border-radius:var(--ib-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ib-shadow)\n    }\n    .iblgcr-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ib-line);\n      border-radius:999px;background:var(--ib-soft);color:var(--ib-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblgcr-product h2{\n      font-size:var(--ib-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ib-accent)\n    }\n    .iblgcr-product h3{\n      font-size:var(--ib-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ib-accent)\n    }\n    .iblgcr-product p{margin:0 0 14px;font-size:var(--ib-content-size);line-height:var(--ib-content-lh)}\n    .iblgcr-product p:last-child{margin-bottom:0}\n    .iblgcr-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ib-soft);border:1px solid var(--ib-line)\n    }\n    .iblgcr-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblgcr-card{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:var(--ib-soft)\n    }\n    .iblgcr-card strong{display:block;margin-bottom:6px;color:var(--ib-accent)}\n    .iblgcr-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ib-accent);\n      background:var(--ib-soft2);border-radius:12px\n    }\n    .iblgcr-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblgcr-list-grid li{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:#fff\n    }\n    .iblgcr-list-grid li strong{display:block;margin-bottom:6px}\n    .iblgcr-bullets{margin:0;padding-left:18px}\n    .iblgcr-bullets li{margin:0 0 10px}\n    .iblgcr-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblgcr-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ib-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblgcr-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ib-accent)\n    }\n    .iblgcr-table thead th{\n      background:var(--ib-soft2);color:var(--ib-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);font-size:15px\n    }\n    .iblgcr-table tbody th,.iblgcr-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblgcr-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ib-accent)}\n    .iblgcr-table tbody tr:last-child th,.iblgcr-table tbody tr:last-child td{border-bottom:none}\n    .iblgcr-download-grid,.iblgcr-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblgcr-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ib-accent);text-decoration:none;color:var(--ib-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblgcr-btn:hover{transform:translateY(-1px);box-shadow:var(--ib-shadow)}\n    .iblgcr-faq details{\n      border:1px solid var(--ib-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblgcr-faq details:last-child{margin-bottom:0}\n    .iblgcr-faq summary{cursor:pointer;font-weight:700;color:var(--ib-accent)}\n    .iblgcr-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblgcr-cards,.iblgcr-list-grid,.iblgcr-download-grid,.iblgcr-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblgcr-product{\n        --ib-content-size:15px;\n        --ib-h2-size:23px;\n        --ib-h3-size:18px;\n      }\n      .iblgcr-hero,.iblgcr-block,.iblgcr-specs,.iblgcr-faq,.iblgcr-downloads,.iblgcr-related{\n        padding:18px;border-radius:16px\n      }\n      .iblgcr-table{min-width:100%;border:0}\n      .iblgcr-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblgcr-table,.iblgcr-table tbody,.iblgcr-table tr,.iblgcr-table th,.iblgcr-table td{\n        display:block;width:100%\n      }\n      .iblgcr-table tr{\n        border:1px solid var(--ib-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblgcr-table tbody th{\n        background:var(--ib-soft2);border-bottom:1px solid var(--ib-line)\n      }\n      .iblgcr-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblgcr-wrap\"\u003e\n    \u003cdiv class=\"iblgcr-hero\"\u003e\n      \u003cdiv class=\"iblgcr-kicker\"\u003eSeguridad CO2 · Cámaras frigoríficas\u003c\/div\u003e\n      \u003ch2\u003eSensor de CO2 para cámaras frigoríficas LogiCO2 con detección fiable en frío\u003c\/h2\u003e\n      \u003cp class=\"iblgcr-snippet\"\u003e\u003cstrong\u003eEl conjunto 3349 de LogiCO2 es un sistema de detección de CO2 para cámaras frigoríficas y congeladores con sensor Cold Room, unidad central Mk9 y sirena\/baliza para vigilar fugas en entornos fríos donde un detector convencional puede perder precisión.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eQué aporta este producto\u003c\/h2\u003e\n      \u003cp\u003eEste equipo está pensado para cámaras frigoríficas y aplicaciones de congelación donde el CO2 puede acumularse por una fuga y un detector estándar no ofrece una respuesta suficientemente fiable a baja temperatura.\u003c\/p\u003e\n      \u003cp\u003eLa ventaja real de este conjunto es que ya integra la base del sistema: sensor específico para frío, unidad central Mk9, sirena\/baliza, fuente de alimentación, conectores, señalización y cubierta de protección. Esto reduce errores de configuración y simplifica una instalación técnica bien resuelta.\u003c\/p\u003e\n      \u003cp\u003eAdemás, el fabricante indica que la solución Cold Room está especialmente adaptada a frío y congelación, y que el sensor se diferencia del Mk90 estándar en el rango de temperatura y en un nivel de alarma configurable mediante DIP-switch 1.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eDatos clave\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-cards\"\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          3349\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG007\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eAplicación principal\u003c\/strong\u003e\n          Cámaras frigoríficas y congeladores\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eSensor\u003c\/strong\u003e\n          Cold Room CO2 Sensor\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eCentral incluida\u003c\/strong\u003e\n          Unidad central Mk9\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eTemperatura de trabajo del sensor\u003c\/strong\u003e\n          De -40 °C a 25 °C\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblgcr-note\"\u003e\n        \u003cstrong\u003eImportante:\u003c\/strong\u003e este producto está orientado a entornos fríos. Si tu instalación tiene varios puntos de riesgo o varias cámaras, la propia documentación del fabricante contempla ampliación mediante kits adicionales y hasta doce sensores sobre una unidad central.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eCaracterísticas principales\u003c\/h2\u003e\n      \u003cul class=\"iblgcr-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDiseñado para frío real\u003c\/strong\u003e El fabricante lo adapta específicamente para cámaras frigoríficas y congeladores, donde un detector convencional puede desviarse más.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eConjunto base completo\u003c\/strong\u003e Incluye sensor Cold Room, unidad central Mk9, sirena\/baliza, fuente, conectores, cableado, manual y señalización.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDetección precisa de CO2\u003c\/strong\u003e Está planteado para seguridad en entornos donde una fuga puede pasar desapercibida si el sensor no está preparado para baja temperatura.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eArquitectura profesional\u003c\/strong\u003e Usa comunicación RS485 Modbus, habitual en sistemas técnicos de supervisión.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAmpliable\u003c\/strong\u003e Se pueden conectar hasta doce sensores a una unidad central y los kits adicionales se integran en modo plug and play.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAlarma visual y acústica\u003c\/strong\u003e La sirena\/baliza estroboscópica ayuda a advertir tanto dentro como fuera de la zona vigilada.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompensación de altitud\u003c\/strong\u003e El sensor puede ajustarse para compensar la altitud de la instalación.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCalibración automática\u003c\/strong\u003e Realiza autocalibración varias veces al año.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-specs\"\u003e\n      \u003ch2\u003eEspecificaciones técnicas\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-table-wrap\"\u003e\n        \u003ctable class=\"iblgcr-table\"\u003e\n          \u003ccaption\u003eEspecificaciones técnicas confirmadas del conjunto LogiCO2 Cold Room 3349\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarca\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModelo\u003c\/th\u003e\n              \u003ctd\u003eCO2 Cold room Mk90 Detector Base SET \/ Conjunto de sensores de CO2 para cámaras frigoríficas\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG007\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e3349\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTipo de equipo\u003c\/th\u003e\n              \u003ctd\u003eSistema base de detección de CO2 para cámaras frigoríficas y congeladores\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAplicación\u003c\/th\u003e\n              \u003ctd\u003eCold room y freezer applications\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eComponentes principales del conjunto\u003c\/th\u003e\n              \u003ctd\u003eSensor CO2 Cold Room + Central Unit Mk9 + Horn\/Strobe LED amber glass + Power Supply 1A + Protection Cover\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eReferencia de sensor\u003c\/th\u003e\n              \u003ctd\u003e1153\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eReferencia unidad central\u003c\/th\u003e\n              \u003ctd\u003e1148\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eReferencia sirena\/baliza\u003c\/th\u003e\n              \u003ctd\u003e0440\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eReferencia fuente de alimentación\u003c\/th\u003e\n              \u003ctd\u003e0021\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eReferencia cubierta de protección\u003c\/th\u003e\n              \u003ctd\u003e0185\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFuente de alimentación del sistema\u003c\/th\u003e\n              \u003ctd\u003e12-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eComunicación\u003c\/th\u003e\n              \u003ctd\u003eRS485 Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCalibración automática\u003c\/th\u003e\n              \u003ctd\u003eVarias veces al año\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtección contra penetración del sensor\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura de funcionamiento del sensor\u003c\/th\u003e\n              \u003ctd\u003eDe -40 °C a 25 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eNiveles de alarma predeterminados\u003c\/th\u003e\n              \u003ctd\u003e5000 ppm indicación de concienciación, 5000 ppm alarma TWA\/8 h, 1,5 % alarma baja, 3,0 % alarma alta\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAjuste adicional\u003c\/th\u003e\n              \u003ctd\u003eCompensación de altitud\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza tensión nominal\u003c\/th\u003e\n              \u003ctd\u003e18-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza consumo\u003c\/th\u003e\n              \u003ctd\u003ePico de 80 mA con fuente de 24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza intensidad acústica\u003c\/th\u003e\n              \u003ctd\u003e110 dB \/ 1 m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza intensidad del flash\u003c\/th\u003e\n              \u003ctd\u003e115 CD\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza frecuencia del flash\u003c\/th\u003e\n              \u003ctd\u003e65\/min\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza temperatura ambiente\u003c\/th\u003e\n              \u003ctd\u003eDe -5 °C a +50 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza dimensiones\u003c\/th\u003e\n              \u003ctd\u003e134 x 115 x 61 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza protección\u003c\/th\u003e\n              \u003ctd\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUnidad central comunicación\u003c\/th\u003e\n              \u003ctd\u003eRS485, Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUnidad central pantalla\u003c\/th\u003e\n              \u003ctd\u003eGráfica 128x64, retroiluminada\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUnidad central señal acústica\u003c\/th\u003e\n              \u003ctd\u003e80 dBa (1 m) máx.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUnidad central temperatura ambiente\u003c\/th\u003e\n              \u003ctd\u003eDe 0 a +40 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUnidad central humedad\u003c\/th\u003e\n              \u003ctd\u003e0-90 % sin condensación\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUnidad central dimensiones\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUnidad central protección\u003c\/th\u003e\n              \u003ctd\u003eIP54 según TÜV, IP44 según UL\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCapacidad de expansión\u003c\/th\u003e\n              \u003ctd\u003eHasta 12 sensores conectados a una unidad central\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eContenido del suministro\u003c\/th\u003e\n              \u003ctd\u003eCO2 Mk90 incl. 1 cable azul de 10 m y 1 cable rojo de 5 m, sirena\/baliza estroboscópica con vidrio ámbar led con indicador azul incl. cable de 1 m y letrero, bifurcador RJ45 1-1, transformador de 1 A, bloqueo de enchufe, bolsa con 3 juntas de casquillo, 6 tiras, 24 tornillos y tacos, letreros, manual Mk90, guía rápida Mk90 y cubierta de protección.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCertificaciones y cumplimiento\u003c\/th\u003e\n              \u003ctd\u003eCE, UL, DIN6653-2 2015-06, EN55022:2006\/A1:2007, EN55024\/A2:2003, EN61000-3-2:2006, EN61000-3-3\/A2:2006, AS\/NZS CISPR 22:2006, IEC\/EN IT55022\/55024, LNE Règle de certification NF 128.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGTIN\/EAN\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePeso\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eCompatibilidad y casos de uso\u003c\/h2\u003e\n      \u003cp\u003eEste conjunto está pensado para cámaras frigoríficas, congeladores, zonas de almacenamiento frío, cuartos de gas vinculados a cámaras y otros espacios interiores fríos donde se use CO2 y exista riesgo de acumulación por fuga.\u003c\/p\u003e\n      \u003cp\u003eEncaja en hostelería, retail alimentario, bodegas, cervecerías, productores de bebidas, industria alimentaria y cualquier instalación donde el CO2 se utilice en zonas frías o recintos de baja temperatura.\u003c\/p\u003e\n      \u003cp\u003eLa propia documentación del fabricante contempla ampliación mediante kits adicionales, kits de relé y conexión a sistemas de gestión de edificios, siempre dentro de la arquitectura LogiCO2.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eInstalación y consideraciones antes de comprar\u003c\/h2\u003e\n      \u003cul class=\"iblgcr-bullets\"\u003e\n        \u003cli\u003eEl sensor debe instalarse a una altura máxima de 30 cm del suelo y a una distancia máxima de 5 m del punto de distribución de CO2.\u003c\/li\u003e\n        \u003cli\u003eCada sensor cubre un área máxima de 78 m²; si la cámara o zona es mayor, valora sensores adicionales.\u003c\/li\u003e\n        \u003cli\u003eLa sirena\/baliza debe colocarse sobre el sensor, aproximadamente a 2-2,4 m del suelo, claramente visible desde cualquier entrada.\u003c\/li\u003e\n        \u003cli\u003eLa documentación recomienda colocar además una segunda sirena\/baliza fuera de la zona vigilada, preferiblemente sobre la puerta o puertas de acceso.\u003c\/li\u003e\n        \u003cli\u003eLa unidad central debe instalarse fuera de la zona vigilada, en una posición visible y accesible.\u003c\/li\u003e\n        \u003cli\u003eComprueba la alimentación disponible, el tendido del cableado RJ45 y la compatibilidad con la arquitectura del sistema si prevés ampliaciones.\u003c\/li\u003e\n        \u003cli\u003eAl ser un producto de seguridad, la instalación y puesta en marcha deben realizarse con criterio técnico y verificación funcional final.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eMantenimiento y uso recomendado\u003c\/h2\u003e\n      \u003cp\u003eEl sensor realiza calibración automática varias veces al año. Aun así, por tratarse de un sistema de seguridad CO2, es recomendable revisar periódicamente cables, conectores, visibilidad de la señalización, sirena\/baliza y lectura correcta en la unidad central.\u003c\/p\u003e\n      \u003cp\u003eLa documentación general del sistema recomienda que un agente profesional cualificado realice una comprobación de funcionamiento al menos una vez al año. La limpieza debe hacerse con agua y un paño humedecido, evitando manipulaciones no autorizadas del equipo.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-faq\"\u003e\n      \u003ch2\u003ePreguntas frecuentes\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Este producto es para cámaras frigoríficas y congeladores?\u003c\/summary\u003e\n        \u003cp\u003eSí. El artículo 3349 está diseñado específicamente para aplicaciones de cámara frigorífica y freezer.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Incluye unidad central Mk9?\u003c\/summary\u003e\n        \u003cp\u003eSí. Este conjunto base incluye sensor Cold Room, unidad central Mk9, sirena\/baliza, fuente de alimentación, conectores, manual y señalización.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿En qué se diferencia de un detector convencional?\u003c\/summary\u003e\n        \u003cp\u003eLa propia ficha del fabricante explica que los detectores convencionales no están diseñados para entornos fríos y pueden tener un margen de error elevado. Este sensor está adaptado a bajas temperaturas.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Dónde debe instalarse el sensor?\u003c\/summary\u003e\n        \u003cp\u003eDebe montarse a un máximo de 30 cm del suelo y a un máximo de 5 m del punto de distribución de CO2. Cada sensor cubre hasta 78 m².\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Se puede ampliar el sistema?\u003c\/summary\u003e\n        \u003cp\u003eSí. La documentación del artículo 3349 indica que se pueden conectar hasta 12 sensores a una unidad central y que los kits adicionales se instalan en modo plug and play.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Necesita mantenimiento periódico?\u003c\/summary\u003e\n        \u003cp\u003eSí. Aunque el sensor realiza calibración automática, conviene hacer control funcional periódico y revisión profesional al menos una vez al año.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-downloads\"\u003e\n      \u003ch2\u003eDescargables\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-download-grid\"\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/CO2_Coldroom_SensorSET_3349_es_db_LogiCO2.pdf?v=1775036243\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eFicha técnica LogiCO2 3349\u003c\/a\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManual Mk9 \/ Mk90\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-related\"\u003e\n      \u003ch2\u003eTambién puede interesarte\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-related-grid\"\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"\/es-eea\/collections\/alarmas-detectores-co2-logico2\"\u003eAlarmas y detectores de CO2 LogiCO2\u003c\/a\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"\/es-eea\/pages\/servicio-tecnico\"\u003eAsesoramiento e instalación técnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57238894084444,"sku":"LG007","price":618.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/coldroom-co2sensor-set-logico2.webp?v=1775036636","url":"https:\/\/installbeer.com\/es-eea\/products\/conjunto-sensores-co2-camaras-frigorificas-logico2-mk90","provider":"Install Beer","version":"1.0","type":"link"}