{"product_id":"rcb-retardo-reinicio-silencio-logico2","title":"Additional RCB kit with relay delay, reset and mute function LogiCO2","description":"\u003cstyle\u003e\n    .ibrcb-product{\n      --ibrcb-max:1120px;\n      --ibrcb-text:#1f2328;\n      --ibrcb-muted:#5b6573;\n      --ibrcb-line:#e6e8eb;\n      --ibrcb-soft:#f7f8fa;\n      --ibrcb-soft2:#f2f4f6;\n      --ibrcb-accent:#111111;\n      --ibrcb-radius:18px;\n      --ibrcb-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibrcb-content-size:16px;\n      --ibrcb-content-lh:1.68;\n      --ibrcb-h2-size:28px;\n      --ibrcb-h3-size:20px;\n      color:var(--ibrcb-text);\n      font-size:var(--ibrcb-content-size);\n      line-height:var(--ibrcb-content-lh);\n    }\n    .ibrcb-product *{box-sizing:border-box}\n    .ibrcb-wrap{max-width:var(--ibrcb-max);margin:0 auto;padding:4px 0 36px}\n    .ibrcb-hero,.ibrcb-block,.ibrcb-specs,.ibrcb-faq,.ibrcb-downloads,.ibrcb-related{\n      background:#fff;border:1px solid var(--ibrcb-line);border-radius:var(--ibrcb-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibrcb-shadow)\n    }\n    .ibrcb-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibrcb-line);\n      border-radius:999px;background:var(--ibrcb-soft);color:var(--ibrcb-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibrcb-product h2{\n      font-size:var(--ibrcb-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibrcb-accent)\n    }\n    .ibrcb-product h3{\n      font-size:var(--ibrcb-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibrcb-accent)\n    }\n    .ibrcb-product p{\n      margin:0 0 14px;\n      font-size:var(--ibrcb-content-size);\n      line-height:var(--ibrcb-content-lh)\n    }\n    .ibrcb-product p:last-child{margin-bottom:0}\n    .ibrcb-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibrcb-soft);border:1px solid var(--ibrcb-line)\n    }\n    .ibrcb-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibrcb-card{\n      padding:16px;border:1px solid var(--ibrcb-line);border-radius:16px;background:var(--ibrcb-soft)\n    }\n    .ibrcb-card strong{display:block;margin-bottom:6px;color:var(--ibrcb-accent)}\n    .ibrcb-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibrcb-accent);\n      background:var(--ibrcb-soft2);border-radius:12px\n    }\n    .ibrcb-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibrcb-list-grid li{\n      padding:16px;border:1px solid var(--ibrcb-line);border-radius:16px;background:#fff\n    }\n    .ibrcb-list-grid li strong{display:block;margin-bottom:6px}\n    .ibrcb-bullets{margin:0;padding-left:18px}\n    .ibrcb-bullets li{margin:0 0 10px}\n    .ibrcb-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibrcb-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibrcb-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibrcb-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibrcb-accent)\n    }\n    .ibrcb-table thead th{\n      background:var(--ibrcb-soft2);color:var(--ibrcb-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibrcb-line);font-size:15px\n    }\n    .ibrcb-table tbody th,.ibrcb-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibrcb-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibrcb-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibrcb-accent)}\n    .ibrcb-table tbody tr:last-child th,.ibrcb-table tbody tr:last-child td{border-bottom:none}\n    .ibrcb-download-grid,.ibrcb-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibrcb-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibrcb-accent);text-decoration:none;color:var(--ibrcb-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibrcb-btn:hover{transform:translateY(-1px);box-shadow:var(--ibrcb-shadow)}\n    .ibrcb-faq details{\n      border:1px solid var(--ibrcb-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibrcb-faq details:last-child{margin-bottom:0}\n    .ibrcb-faq summary{cursor:pointer;font-weight:700;color:var(--ibrcb-accent)}\n    .ibrcb-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibrcb-cards,.ibrcb-list-grid,.ibrcb-download-grid,.ibrcb-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibrcb-product{\n        --ibrcb-content-size:15px;\n        --ibrcb-h2-size:23px;\n        --ibrcb-h3-size:18px;\n      }\n      .ibrcb-hero,.ibrcb-block,.ibrcb-specs,.ibrcb-faq,.ibrcb-downloads,.ibrcb-related{\n        padding:18px;border-radius:16px\n      }\n      .ibrcb-table{min-width:100%;border:0}\n      .ibrcb-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibrcb-table,.ibrcb-table tbody,.ibrcb-table tr,.ibrcb-table th,.ibrcb-table td{\n        display:block;width:100%\n      }\n      .ibrcb-table tr{\n        border:1px solid var(--ibrcb-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibrcb-table tbody th{\n        background:var(--ibrcb-soft2);border-bottom:1px solid var(--ibrcb-line)\n      }\n      .ibrcb-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\u003csection class=\"ibrcb-product ibrcb-0472\" data-brand=\"LogiCO2\" data-model=\"RCB with relay delay, reset button and mute on\/off Add-on KIT\"\u003e\n\u003cdiv class=\"ibrcb-wrap\"\u003e\n\u003cdiv class=\"ibrcb-hero\"\u003e\n\u003cdiv class=\"ibrcb-kicker\"\u003eTechnical accessory · LogiCO2 Safety System\u003c\/div\u003e\n\u003ch2\u003eLogiCO2 RCB to transmit alarms to external devices with greater control\u003c\/h2\u003e\n\u003cp class=\"ibrcb-snippet\"\u003e\u003cstrong\u003eThe LogiCO2 RCB is a remote connection box that transmits pre-alarms and high alarms to external devices, such as sirens and beacons, and adds delay, manual reset and silence functions.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-block\"\u003e\n\u003ch2\u003eWhat this product offers\u003c\/h2\u003e\n\u003cp\u003eThis accessory is intended for LogiCO2 installations where the system’s local alarm is not enough and external devices, such as a horn\/strobe, need to be activated with more controlled logic.\u003c\/p\u003e\n\u003cp\u003eIts real value is that it not only replicates an alarm output, but also incorporates management via relays, selection of pre-alarm or high alarm, delay to avoid unwanted alerts during tests, and latching functions with manual reset.\u003c\/p\u003e\n\u003cp\u003eIn hospitality, beverage industry, wineries or technical rooms, this helps to better integrate the safety system with remote signaling or internal emergency protocols.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-block\"\u003e\n\u003ch2\u003eKey data\u003c\/h2\u003e\n\u003cdiv class=\"ibrcb-cards\"\u003e\n\u003cdiv class=\"ibrcb-card\"\u003e\n\u003cstrong\u003eManufacturer’s part number\u003c\/strong\u003e 0472\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-card\"\u003e\n\u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e LG011\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-card\"\u003e\n\u003cstrong\u003eMain function\u003c\/strong\u003e Transmit alarms to external devices\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-card\"\u003e\n\u003cstrong\u003eRelés\u003c\/strong\u003e 2 dry changeover relays\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-card\"\u003e\n\u003cstrong\u003eConfigurable delay\u003c\/strong\u003e 9,5 segundos\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-card\"\u003e\n\u003cstrong\u003ePower supply\u003c\/strong\u003e Via sensor\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-note\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e this RCB does not replace the sensor or the control unit. It is an accessory to extend the activation logic of external devices within the LogiCO2 system.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-block\"\u003e\n\u003ch2\u003eMain features\u003c\/h2\u003e\n\u003cul class=\"ibrcb-list-grid\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo dedicated relays\u003c\/strong\u003e Includes one relay for pre-alarm and another for high alarm, with the possibility of reassignment via DIP switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVolt-free contact\u003c\/strong\u003e The relays can be configured as dry contact, useful for external integrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9.5 s delay\u003c\/strong\u003e Helps prevent unwanted calls or activations during system testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLatching functions\u003c\/strong\u003e It can latch after 9.5 s and require manual reset.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorn\/strobe mute\u003c\/strong\u003e Allows the siren\/beacon to be silenced during high alarm in certain configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIP-switch configuration\u003c\/strong\u003e Each relay can be independently adjusted for function, activation and normal state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple blue RJ45 connection\u003c\/strong\u003e Works on the sensor alarm output cable and towards the external device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact design\u003c\/strong\u003e Robust, compact housing, suitable for protected technical installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-specs\"\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cdiv class=\"ibrcb-table-wrap\"\u003e\n\u003ctable class=\"ibrcb-table\"\u003e\n\u003ccaption\u003eConfirmed technical specifications of the LogiCO2 RCB\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eConfirmed data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eLogiCO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eRCB with relay delay, reset button and mute on\/off Add-on KIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eLG011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMPN \/ manufacturer part number\u003c\/th\u003e\n\u003ctd\u003e0472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n\u003ctd\u003eRemote junction box for LogiCO2 alarm system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFunction\u003c\/th\u003e\n\u003ctd\u003eTransmit alarm indications to external devices, for example horn\/strobe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelay configuration\u003c\/th\u003e\n\u003ctd\u003e2 dedicated dry changeover relays, one for pre-alarm and one for high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlternative configuration\u003c\/th\u003e\n\u003ctd\u003eBoth relays can be triggered on pre-alarm or high alarm via DIP switch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelay delay\u003c\/th\u003e\n\u003ctd\u003e9,5 segundos\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManual reset\u003c\/th\u003e\n\u003ctd\u003eYes, in latched functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMute\u003c\/th\u003e\n\u003ctd\u003eYes, selectable for horn\/strobe during high alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eVia sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelés\u003c\/th\u003e\n\u003ctd\u003e1 A \/ 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003ePC\/ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e78 x 78 x 37 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiring included\u003c\/th\u003e\n\u003ctd\u003e2 one‑meter CAT5 cables with blue RJ45 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput connection\u003c\/th\u003e\n\u003ctd\u003eTo the sensor alarm output cable with blue RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput connection\u003c\/th\u003e\n\u003ctd\u003eTo the horn\/strobe alarm device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd\u003eRCB, two 1 m cables, one RJ45 1–2 splitter and one beacon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-block\"\u003e\n\u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n\u003cp\u003eThe RCB is designed as an accessory for LogiCO2 alarm systems and for activating external devices, especially horn\/strobe units.\u003c\/p\u003e\n\u003cp\u003eIt is suitable for installations where you want to separate remote signaling from the sensor, add delay logic, or require a manual reset after a sustained alarm.\u003c\/p\u003e\n\u003cp\u003eIt is especially useful in technical rooms, hospitality venues, breweries, wineries and other installations where an external signal must be managed with more control than a simple direct output.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-block\"\u003e\n\u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n\u003cul class=\"ibrcb-bullets\"\u003e\n\u003cli\u003eInstall the box in a suitable, mechanically protected location.\u003c\/li\u003e\n\u003cli\u003eThe cover opens by twisting and must be removed to access the mounting point.\u003c\/li\u003e\n\u003cli\u003eBefore purchasing, confirm that you really need external relay logic and not just the horn\/strobe connected directly to the system.\u003c\/li\u003e\n\u003cli\u003eCheck whether you need to act on pre-alarm, high alarm, or both, because the configuration is done via DIP switches.\u003c\/li\u003e\n\u003cli\u003eIf the project requires interlocking and manual reset, select an appropriate latch function.\u003c\/li\u003e\n\u003cli\u003eIf you want to avoid unwanted triggering during tests, use the 9.5-second delay option.\u003c\/li\u003e\n\u003cli\u003eIf the external device must remain active under normal conditions or only be activated in alarm, check the position of the relay function DIP switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-block\"\u003e\n\u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n\u003cp\u003eFor this type of accessory it is advisable to periodically check the RJ45 cabling, the mechanical fastening, the integrity of the cover and the logic selected on the DIP switches, especially after any intervention or expansion of the system.\u003c\/p\u003e\n\u003cp\u003eIt is also advisable to perform controlled tests of relay activation and verify that the mute, delay and manual reset functions respond as required by the installation protocol.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-faq\"\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails open\u003e\n\u003csummary\u003e¿Para qué sirve exactamente la RCB?\u003c\/summary\u003e\n\u003cp\u003eIt is used to transmit pre-alarms and alarms to external devices, for example a horn\/strobe, adding delay, reset and mute functions.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open\u003e\n\u003csummary\u003eDoes it include independent relays?\u003c\/summary\u003e\n\u003cp\u003eYes. It has two dedicated relays, one for pre‑alarm and one for high alarm, with reconfiguration options.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open\u003e\n\u003csummary\u003eWhat delay does it include?\u003c\/summary\u003e\n\u003cp\u003eIt can apply a 9.5-second delay before activating the relay, useful for avoiding unwanted alerts during tests.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open\u003e\n\u003csummary\u003eDoes it allow manual reset?\u003c\/summary\u003e\n\u003cp\u003eYes. Some functions include latching and require manual reset.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open\u003e\n\u003csummary\u003eCan the horn\/strobe be muted?\u003c\/summary\u003e\n\u003cp\u003eYes. Mute can be enabled by DIP switch for the horn\/strobe during high alarm.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open\u003e\n\u003csummary\u003eWhat does the kit include?\u003c\/summary\u003e\n\u003cp\u003eIncludes the RCB box, two 1‑meter CAT5 cables, an RJ45 1‑2 splitter and a sign.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-downloads\"\u003e\n\u003ch2\u003eDownloadable\u003c\/h2\u003e\n\u003cdiv class=\"ibrcb-download-grid\"\u003e\n\u003ca class=\"ibrcb-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/RCB_delay_reset_mute_AddonKIT.pdf?v=1776184228\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eRCB datasheet\u003c\/a\u003e \u003ca class=\"ibrcb-btn\" href=\"https:\/\/www.logico2.com\/products\/remote-connection-box-with-delay-reset-and-mute-function\/\" rel=\"noopener noreferrer\" target=\"_blank\"\u003ePágina oficial del producto\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ibrcb-related\"\u003e\n\u003ch2\u003eYou may also be interested in\u003c\/h2\u003e\n\u003cdiv class=\"ibrcb-related-grid\"\u003e\n\u003ca class=\"ibrcb-btn\" href=\"\/en\/collections\/logico2-detectores-co2-seguridad-industrial-horeca\"\u003eLogiCO2 products\u003c\/a\u003e \u003ca class=\"ibrcb-btn\" href=\"\/en\/pages\/servicio-tecnico\"\u003eTechnical advice and installation\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57365627502940,"sku":"LG011","price":142.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/rcb-delay-reset-cab.webp?v=1776184187","url":"https:\/\/installbeer.com\/en\/products\/rcb-delay-restart-silence-logico2","provider":"Install Beer","version":"1.0","type":"link"}