{"product_id":"rcb-retardo-rele-logico2","title":"Additional RCB kit with LogiCO2 relay delay function","description":"\u003csection class=\"ibrcbd-product ibrcbd-0471\" data-brand=\"LogiCO2\" data-model=\"RCB with relay delay Add-on KIT\"\u003e\n  \u003cstyle\u003e\n    .ibrcbd-product{\n      --ibrcbd-max:1120px;\n      --ibrcbd-text:#1f2328;\n      --ibrcbd-muted:#5b6573;\n      --ibrcbd-line:#e6e8eb;\n      --ibrcbd-soft:#f7f8fa;\n      --ibrcbd-soft2:#f2f4f6;\n      --ibrcbd-accent:#111111;\n      --ibrcbd-radius:18px;\n      --ibrcbd-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibrcbd-content-size:16px;\n      --ibrcbd-content-lh:1.68;\n      --ibrcbd-h2-size:28px;\n      --ibrcbd-h3-size:20px;\n      color:var(--ibrcbd-text);\n      font-size:var(--ibrcbd-content-size);\n      line-height:var(--ibrcbd-content-lh);\n    }\n    .ibrcbd-product *{box-sizing:border-box}\n    .ibrcbd-wrap{max-width:var(--ibrcbd-max);margin:0 auto;padding:4px 0 36px}\n    .ibrcbd-hero,.ibrcbd-block,.ibrcbd-specs,.ibrcbd-faq,.ibrcbd-downloads,.ibrcbd-related{\n      background:#fff;border:1px solid var(--ibrcbd-line);border-radius:var(--ibrcbd-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibrcbd-shadow)\n    }\n    .ibrcbd-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibrcbd-line);\n      border-radius:999px;background:var(--ibrcbd-soft);color:var(--ibrcbd-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibrcbd-product h2{\n      font-size:var(--ibrcbd-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibrcbd-accent)\n    }\n    .ibrcbd-product h3{\n      font-size:var(--ibrcbd-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibrcbd-accent)\n    }\n    .ibrcbd-product p{\n      margin:0 0 14px;\n      font-size:var(--ibrcbd-content-size);\n      line-height:var(--ibrcbd-content-lh)\n    }\n    .ibrcbd-product p:last-child{margin-bottom:0}\n    .ibrcbd-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibrcbd-soft);border:1px solid var(--ibrcbd-line)\n    }\n    .ibrcbd-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibrcbd-card{\n      padding:16px;border:1px solid var(--ibrcbd-line);border-radius:16px;background:var(--ibrcbd-soft)\n    }\n    .ibrcbd-card strong{display:block;margin-bottom:6px;color:var(--ibrcbd-accent)}\n    .ibrcbd-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibrcbd-accent);\n      background:var(--ibrcbd-soft2);border-radius:12px\n    }\n    .ibrcbd-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibrcbd-list-grid li{\n      padding:16px;border:1px solid var(--ibrcbd-line);border-radius:16px;background:#fff\n    }\n    .ibrcbd-list-grid li strong{display:block;margin-bottom:6px}\n    .ibrcbd-bullets{margin:0;padding-left:18px}\n    .ibrcbd-bullets li{margin:0 0 10px}\n    .ibrcbd-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibrcbd-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibrcbd-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibrcbd-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibrcbd-accent)\n    }\n    .ibrcbd-table thead th{\n      background:var(--ibrcbd-soft2);color:var(--ibrcbd-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibrcbd-line);font-size:15px\n    }\n    .ibrcbd-table tbody th,.ibrcbd-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibrcbd-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibrcbd-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibrcbd-accent)}\n    .ibrcbd-table tbody tr:last-child th,.ibrcbd-table tbody tr:last-child td{border-bottom:none}\n    .ibrcbd-download-grid,.ibrcbd-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibrcbd-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibrcbd-accent);text-decoration:none;color:var(--ibrcbd-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibrcbd-btn:hover{transform:translateY(-1px);box-shadow:var(--ibrcbd-shadow)}\n    .ibrcbd-faq details{\n      border:1px solid var(--ibrcbd-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibrcbd-faq details:last-child{margin-bottom:0}\n    .ibrcbd-faq summary{cursor:pointer;font-weight:700;color:var(--ibrcbd-accent)}\n    .ibrcbd-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibrcbd-cards,.ibrcbd-list-grid,.ibrcbd-download-grid,.ibrcbd-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibrcbd-product{\n        --ibrcbd-content-size:15px;\n        --ibrcbd-h2-size:23px;\n        --ibrcbd-h3-size:18px;\n      }\n      .ibrcbd-hero,.ibrcbd-block,.ibrcbd-specs,.ibrcbd-faq,.ibrcbd-downloads,.ibrcbd-related{\n        padding:18px;border-radius:16px\n      }\n      .ibrcbd-table{min-width:100%;border:0}\n      .ibrcbd-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibrcbd-table,.ibrcbd-table tbody,.ibrcbd-table tr,.ibrcbd-table th,.ibrcbd-table td{\n        display:block;width:100%\n      }\n      .ibrcbd-table tr{\n        border:1px solid var(--ibrcbd-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibrcbd-table tbody th{\n        background:var(--ibrcbd-soft2);border-bottom:1px solid var(--ibrcbd-line)\n      }\n      .ibrcbd-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibrcbd-wrap\"\u003e\n    \u003cdiv class=\"ibrcbd-hero\"\u003e\n      \u003cdiv class=\"ibrcbd-kicker\"\u003eTechnical accessory · LogiCO2 Safety System\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 RCB with relay delay for external panels and ventilation\u003c\/h2\u003e\n      \u003cp class=\"ibrcbd-snippet\"\u003e\u003cstrong\u003eThe RCB with LogiCO2 relay delay add‑on kit transmits pre‑alarm or high‑alarm signals to external devices, such as a fire alarm panel or a fan, with the option of direct activation or a 9.5‑second delay.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibrcbd-block\"\u003e\n      \u003ch2\u003eWhat this product offers\u003c\/h2\u003e\n      \u003cp\u003eThis accessory is intended for installations where the LogiCO2 system must not only give local warning, but also send the signal to external equipment. The manufacturer’s examples are clear: fire alarm panel or starting ventilation.\u003c\/p\u003e\n      \u003cp\u003eThe operational advantage over a simple output is that it includes dedicated relays and a 9.5‑second delay, useful to avoid unwanted calls or trips during system testing.\u003c\/p\u003e\n      \u003cp\u003eIn technical installations in hospitality, wineries, breweries, or the beverage industry, it is a useful component when the design requires integration with other safety or extraction equipment.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibrcbd-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"ibrcbd-cards\"\u003e\n        \u003cdiv class=\"ibrcbd-card\"\u003e\n          \u003cstrong\u003eManufacturer’s part number\u003c\/strong\u003e\n          0471\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibrcbd-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG016\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibrcbd-card\"\u003e\n          \u003cstrong\u003eMain function\u003c\/strong\u003e\n          Transmit alarms to external equipment\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibrcbd-card\"\u003e\n          \u003cstrong\u003eRelays\u003c\/strong\u003e\n          2 dedicated dry relays\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibrcbd-card\"\u003e\n          \u003cstrong\u003eRetardo configurable\u003c\/strong\u003e\n          9.5 seconds\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibrcbd-card\"\u003e\n          \u003cstrong\u003eConnection\u003c\/strong\u003e\n          Blue CAT5 RJ45 cable\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"ibrcbd-note\"\u003e\n        \u003cstrong\u003eImportant:\u003c\/strong\u003e this product is neither a control unit nor a sensor. It is a remote connection box to extend alarm transmission to external equipment within the LogiCO2 system.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibrcbd-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"ibrcbd-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTwo independent relays\u003c\/strong\u003e Includes one relay dedicated to pre-alarm and another to high alarm.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eVolt‑free relays\u003c\/strong\u003e The documentation defines them as dry changeover relays.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUseful delay for testing\u003c\/strong\u003e It can activate the relays with a 9.5‑second delay to avoid accidental alerts when testing the system.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFlexible configuration\u003c\/strong\u003e The DIP switches allow each relay to be assigned to pre‑alarm or high alarm.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndependent selection per relay\u003c\/strong\u003e Each relay can be configured separately.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eNormally‑energized or normally‑de‑energized mode\u003c\/strong\u003e The manufacturer allows you to choose whether the relay remains active in normal state or only during an alarm.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExternal integration\u003c\/strong\u003e Designed to send a signal to a fire alarm panel or to start a fan.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompact format\u003c\/strong\u003e Small, protected electronic box for neat technical installations.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibrcbd-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"ibrcbd-table-wrap\"\u003e\n        \u003ctable class=\"ibrcbd-table\"\u003e\n          \u003ccaption\u003eConfirmed technical specifications of the RCB with LogiCO2 relay delay add-on KIT\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eConfirmed data\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eRCB with relay delay Add-on KIT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG016\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ manufacturer part number\u003c\/th\u003e\n              \u003ctd\u003e0471\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003eRemote junction box for CO2 safety system\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFunction\u003c\/th\u003e\n              \u003ctd\u003eTransmit alarm indications to external devices, for example a fire alarm panel or fan\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eRelays\u003c\/th\u003e\n              \u003ctd\u003e2 dedicated potential‑free (dry) changeover relays\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eRelay assignment\u003c\/th\u003e\n              \u003ctd\u003eOne for pre‑alarm and one for high alarm; you can also set both to pre‑alarm or both to high alarm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eActivation\u003c\/th\u003e\n              \u003ctd\u003eInstant or delayed 9.5 seconds\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n              \u003ctd\u003eVia the LogiCO2 sensor\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eNominal relays\u003c\/th\u003e\n              \u003ctd\u003e1 A \/ 24 V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n              \u003ctd\u003ePC\/ABS\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n              \u003ctd\u003e78 x 78 x 37 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n              \u003ctd\u003eIP55\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCable incluido\u003c\/th\u003e\n              \u003ctd\u003e1-meter CAT5 cable with blue RJ45 connector\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConexión de entrada\u003c\/th\u003e\n              \u003ctd\u003eTo the LogiCO2 sensor alarm output cable, also with blue RJ45 connector\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConnection of the external device\u003c\/th\u003e\n              \u003ctd\u003eThrough the pre‑assembled cable gland\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003eElectronics box, 1‑meter cable and 1-to-4 RJ45 splitter\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n              \u003ctd\u003e500 g\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibrcbd-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThe RCB is designed as an accessory for LogiCO2 alarm systems and takes the signal from the sensor via the blue RJ45 connector.\u003c\/p\u003e\n      \u003cp\u003eIts clearest use case is integration with a fire alarm panel or with ventilation systems that must be activated when the system enters pre-alarm or high alarm.\u003c\/p\u003e\n      \u003cp\u003eIt is particularly useful in projects where the CO2 safety system must interact with external equipment and not be limited to local warning from the sensor or central unit.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibrcbd-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"ibrcbd-bullets\"\u003e\n        \u003cli\u003eInstall the box in a suitable location with mechanical protection.\u003c\/li\u003e\n        \u003cli\u003eThe cover is of the rotary type and opens 1\/8 turn counterclockwise to access the mounting screw.\u003c\/li\u003e\n        \u003cli\u003eBefore purchasing, confirm whether your project really needs an external relay box or only a horn\/strobe or local signaling.\u003c\/li\u003e\n        \u003cli\u003eCheck whether activation should be direct or with a 9.5-second delay.\u003c\/li\u003e\n        \u003cli\u003eAlso check whether the external equipment needs dry contacts or must receive V‑ or V+ on the common, because the manufacturer allows adjustments via jumpers.\u003c\/li\u003e\n        \u003cli\u003eIf you are going to connect it to a fire alarm panel, it’s advisable to define clearly which relay will operate on pre‑alarm and which on high alarm.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibrcbd-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eAs an integration accessory, it is advisable to periodically check the condition of the RJ45 cable, the mechanical mounting, the enclosure closure and the DIP-switch and jumper logic, especially after interventions or system expansions.\u003c\/p\u003e\n      \u003cp\u003eIt is also advisable to carry out controlled activation tests to verify that the selected relay behaves with the expected logic and the correct delay.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibrcbd-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat exactly is the RCB used for?\u003c\/summary\u003e\n        \u003cp\u003eIt is used to transmit LogiCO2 system alarms to external equipment, for example a fire alarm panel or a fan.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes it include two relays?\u003c\/summary\u003e\n        \u003cp\u003eYes. It has two dedicated dry relays, one for pre-alarm and one for high alarm, with the option to reconfigure them.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Qué retardo incorpora?\u003c\/summary\u003e\n        \u003cp\u003eAllows delayed activation of 9.5 seconds.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCan you configure which relay operates on pre-alarm or high alarm?\u003c\/summary\u003e\n        \u003cp\u003eYes. The DIP-switch settings allow you to select that logic for each relay.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIs it a box with dry contacts?\u003c\/summary\u003e\n        \u003cp\u003eYes. The documentation describes it as having volt-free relays, i.e. dry relays.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Qué incluye el kit?\u003c\/summary\u003e\n        \u003cp\u003eIncludes the electronic box, a 1‑meter cable and an RJ45 1‑4 splitter.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibrcbd-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"ibrcbd-download-grid\"\u003e\n        \u003ca class=\"ibrcbd-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/RCB_delay_AddonKIT_logico2.pdf?v=1776203693\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eFicha técnica RCB\u003c\/a\u003e\n        \u003ca class=\"ibrcbd-btn\" href=\"https:\/\/www.logico2.com\/products\/remote-connection-box-with-delay\/\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ePágina oficial del producto\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibrcbd-related\"\u003e\n      \u003ch2\u003eYou may also be interested in\u003c\/h2\u003e\n      \u003cdiv class=\"ibrcbd-related-grid\"\u003e\n        \u003ca class=\"ibrcbd-btn\" href=\"\/en\/collections\/logico2-detectores-co2-seguridad-industrial-horeca\"\u003eLogiCO2 products\u003c\/a\u003e\n        \u003ca class=\"ibrcbd-btn\" href=\"\/en\/pages\/servicio-tecnico\"\u003eTechnical advice and installation\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57365630353756,"sku":"LG016","price":130.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/rcb-delay-logico2.webp?v=1776204446","url":"https:\/\/installbeer.com\/en\/products\/rcb-delay-logical-relay2","provider":"Install Beer","version":"1.0","type":"link"}