{"product_id":"modulo-sensor-o2-logico2-mk9","title":"Additional LogiCO2 Mk9 O2 sensor kit","description":"\u003csection class=\"ibo2m-product ibo2m-1142\" data-brand=\"LogiCO2\" data-model=\"O2 Sensor Mk9\"\u003e\n  \u003cstyle\u003e\n    .ibo2m-product{\n      --ibo2m-max:1120px;\n      --ibo2m-text:#1f2328;\n      --ibo2m-muted:#5b6573;\n      --ibo2m-line:#e6e8eb;\n      --ibo2m-soft:#f7f8fa;\n      --ibo2m-soft2:#f2f4f6;\n      --ibo2m-accent:#111111;\n      --ibo2m-radius:18px;\n      --ibo2m-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibo2m-content-size:16px;\n      --ibo2m-content-lh:1.68;\n      --ibo2m-h2-size:28px;\n      --ibo2m-h3-size:20px;\n      color:var(--ibo2m-text);\n      font-size:var(--ibo2m-content-size);\n      line-height:var(--ibo2m-content-lh);\n    }\n    .ibo2m-product *{box-sizing:border-box}\n    .ibo2m-wrap{max-width:var(--ibo2m-max);margin:0 auto;padding:4px 0 36px}\n    .ibo2m-hero,.ibo2m-block,.ibo2m-specs,.ibo2m-faq,.ibo2m-downloads,.ibo2m-related{\n      background:#fff;border:1px solid var(--ibo2m-line);border-radius:var(--ibo2m-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibo2m-shadow)\n    }\n    .ibo2m-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibo2m-line);\n      border-radius:999px;background:var(--ibo2m-soft);color:var(--ibo2m-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibo2m-product h2{\n      font-size:var(--ibo2m-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibo2m-accent)\n    }\n    .ibo2m-product h3{\n      font-size:var(--ibo2m-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibo2m-accent)\n    }\n    .ibo2m-product p{\n      margin:0 0 14px;\n      font-size:var(--ibo2m-content-size);\n      line-height:var(--ibo2m-content-lh)\n    }\n    .ibo2m-product p:last-child{margin-bottom:0}\n    .ibo2m-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibo2m-soft);border:1px solid var(--ibo2m-line)\n    }\n    .ibo2m-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibo2m-card{\n      padding:16px;border:1px solid var(--ibo2m-line);border-radius:16px;background:var(--ibo2m-soft)\n    }\n    .ibo2m-card strong{display:block;margin-bottom:6px;color:var(--ibo2m-accent)}\n    .ibo2m-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibo2m-accent);\n      background:var(--ibo2m-soft2);border-radius:12px\n    }\n    .ibo2m-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibo2m-list-grid li{\n      padding:16px;border:1px solid var(--ibo2m-line);border-radius:16px;background:#fff\n    }\n    .ibo2m-list-grid li strong{display:block;margin-bottom:6px}\n    .ibo2m-bullets{margin:0;padding-left:18px}\n    .ibo2m-bullets li{margin:0 0 10px}\n    .ibo2m-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibo2m-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibo2m-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibo2m-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibo2m-accent)\n    }\n    .ibo2m-table thead th{\n      background:var(--ibo2m-soft2);color:var(--ibo2m-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibo2m-line);font-size:15px\n    }\n    .ibo2m-table tbody th,.ibo2m-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibo2m-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibo2m-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibo2m-accent)}\n    .ibo2m-table tbody tr:last-child th,.ibo2m-table tbody tr:last-child td{border-bottom:none}\n    .ibo2m-download-grid,.ibo2m-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibo2m-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibo2m-accent);text-decoration:none;color:var(--ibo2m-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibo2m-btn:hover{transform:translateY(-1px);box-shadow:var(--ibo2m-shadow)}\n    .ibo2m-faq details{\n      border:1px solid var(--ibo2m-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibo2m-faq details:last-child{margin-bottom:0}\n    .ibo2m-faq summary{cursor:pointer;font-weight:700;color:var(--ibo2m-accent)}\n    .ibo2m-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibo2m-cards,.ibo2m-list-grid,.ibo2m-download-grid,.ibo2m-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibo2m-product{\n        --ibo2m-content-size:15px;\n        --ibo2m-h2-size:23px;\n        --ibo2m-h3-size:18px;\n      }\n      .ibo2m-hero,.ibo2m-block,.ibo2m-specs,.ibo2m-faq,.ibo2m-downloads,.ibo2m-related{\n        padding:18px;border-radius:16px\n      }\n      .ibo2m-table{min-width:100%;border:0}\n      .ibo2m-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibo2m-table,.ibo2m-table tbody,.ibo2m-table tr,.ibo2m-table th,.ibo2m-table td{\n        display:block;width:100%\n      }\n      .ibo2m-table tr{\n        border:1px solid var(--ibo2m-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibo2m-table tbody th{\n        background:var(--ibo2m-soft2);border-bottom:1px solid var(--ibo2m-line)\n      }\n      .ibo2m-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibo2m-wrap\"\u003e\n    \u003cdiv class=\"ibo2m-hero\"\u003e\n      \u003cdiv class=\"ibo2m-kicker\"\u003eOxygen sensor · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 Mk9 O2 sensor to extend or replace a detection point\u003c\/h2\u003e\n      \u003cp class=\"ibo2m-snippet\"\u003e\u003cstrong\u003eThe LogiCO2 Mk9 O2 sensor module is an optical oxygen sensor for systems with an Mk9 central unit. It measures ambient O2 concentration, displays the value on screen, and generates an alarm when the level drops below a safe threshold.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eWhat this product offers\u003c\/h2\u003e\n      \u003cp\u003eThis product fits as a spare part or extension within an existing LogiCO2 system. It is not a complete kit with central unit, horn, or power supply, but the oxygen sensor module.\u003c\/p\u003e\n      \u003cp\u003eIts technical value lies in optical oxygen measurement with integrated temperature and pressure compensation, low power consumption and long service life. The manufacturer also states that it is factory-calibrated.\u003c\/p\u003e\n      \u003cp\u003eIt is a useful solution in installations where it is necessary to monitor atmospheres with low-oxygen risk and keep the reading integrated within the LogiCO2 Mk9 ecosystem.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2m-cards\"\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eManufacturer’s part number\u003c\/strong\u003e\n          1142\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG012\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eType\u003c\/strong\u003e\n          O2 sensor for system with Mk9 control unit\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eMeasuring range\u003c\/strong\u003e\n          0–25% O2\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eVisual alarm\u003c\/strong\u003e\n          Red for alarm \u003c19.5% O2\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eSales format\u003c\/strong\u003e\n          Spare part without cable\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"ibo2m-note\"\u003e\n        \u003cstrong\u003eImportant:\u003c\/strong\u003e this item is documented as a spare part without cable. Before purchasing, it’s advisable to confirm that you already have the cabling and compatible LogiCO2 Mk9 architecture.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"ibo2m-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOptical O2 sensor\u003c\/strong\u003e Uses the FB-optical principle to measure ambient oxygen concentration.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIntegrated compensation\u003c\/strong\u003e Includes temperature and pressure compensation.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFactory-calibrated\u003c\/strong\u003e The manufacturer supplies it calibrated from the factory.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompatible with Mk9 central unit\u003c\/strong\u003e Communicates via Modbus RTU with the LogiCO2 Mk9 central unit.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompatible with CO2 sensors\u003c\/strong\u003e It can operate together with the different LogiCO2 CO2 sensors within the same system.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBacklit display\u003c\/strong\u003e Shows current O2 concentration and operating hours.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eClear local indication\u003c\/strong\u003e Operation, fault, and alarm LEDs, plus an audible warning for fault or alarm.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompact format\u003c\/strong\u003e Small dimensions for integration in technical installations.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2m-table-wrap\"\u003e\n        \u003ctable class=\"ibo2m-table\"\u003e\n          \u003ccaption\u003eConfirmed technical specifications of the LogiCO2 Mk9 O2 sensor module\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eConfirmed data\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eO2 Sensor Mk9\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG012\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ manufacturer part number\u003c\/th\u003e\n              \u003ctd\u003e1142\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003eOxygen sensor for LogiCO2 Mk9 system\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSupply format\u003c\/th\u003e\n              \u003ctd\u003eWireless sensor, listed as a spare part\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n              \u003ctd\u003e24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating principle\u003c\/th\u003e\n              \u003ctd\u003eFB-optical\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMeasuring range\u003c\/th\u003e\n              \u003ctd\u003e0–25% O2 concentration\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePrecisión\u003c\/th\u003e\n              \u003ctd\u003e\u003c2% FS\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSystem compatibility\u003c\/th\u003e\n              \u003ctd\u003eCompatible with LogiCO2 Mk9 CO2 Safety System\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCommunication\u003c\/th\u003e\n              \u003ctd\u003eModbus RTU with the LogiCO2 Mk9 central unit\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n              \u003ctd\u003eBacklit; displays current O2 concentration and operating hours\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLEDs\u003c\/th\u003e\n              \u003ctd\u003eGreen: operation · Yellow: fault · Red: alarm (\u003c19.5% O2)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAudible alarm\u003c\/th\u003e\n              \u003ctd\u003eFlashing: fault · Steady: alarm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eApprovals\u003c\/th\u003e\n              \u003ctd\u003eUL 61010-1, CAN\/CSA-C22.2 No. 61010-1-12, IEC 60529\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n              \u003ctd\u003ePlastic\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n              \u003ctd\u003e1 Kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003eO2 Mk9 Sensor\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThis sensor is designed to work with the LogiCO2 Mk9 control unit and communicate via Modbus RTU within the safety system.\u003c\/p\u003e\n      \u003cp\u003eThe manufacturer states that it can be used together with the different LogiCO2 CO2 sensors, which makes it useful in mixed installations where different gas risks are monitored within the same architecture.\u003c\/p\u003e\n      \u003cp\u003eIt is suitable as a replacement for an existing sensor or as an expansion of a compatible system, provided the configuration of the assembly and the corresponding wiring are respected.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"ibo2m-bullets\"\u003e\n        \u003cli\u003eConfirm before purchasing that your installation has a compatible LogiCO2 Mk9 central unit.\u003c\/li\u003e\n        \u003cli\u003eCheck whether you need only the sensor or also cabling, since the datasheet defines it as a spare part without cable.\u003c\/li\u003e\n        \u003cli\u003eCheck the reference of the sensor to be replaced to avoid errors during maintenance or expansion.\u003c\/li\u003e\n        \u003cli\u003eIf your system combines CO2 and O2 sensors, check the overall architecture before expanding.\u003c\/li\u003e\n        \u003cli\u003eAl ser un componente de seguridad, la instalación y comprobación funcional deben realizarse con criterio técnico.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eAs this is a safety sensor, it is advisable to periodically check its operating status, the display reading, LED indication, and audible fault or alarm warning.\u003c\/p\u003e\n      \u003cp\u003eAfter any replacement, it is advisable to verify proper communication with the Mk9 control unit and check that the reading and local signaling respond correctly.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIs this product a complete detection system?\u003c\/summary\u003e\n        \u003cp\u003eNo. It is only the O2 sensor module; it does not include a central unit or a complete alarm kit.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Incluye cable?\u003c\/summary\u003e\n        \u003cp\u003eThe datasheet lists it as a spare part without cable.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhich central unit is it compatible with?\u003c\/summary\u003e\n        \u003cp\u003eIt is compatible with the LogiCO2 Mk9 central unit and communicates via Modbus RTU.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCan it operate together with CO2 sensors?\u003c\/summary\u003e\n        \u003cp\u003eYes. The manufacturer states that it can be used together with the different LogiCO2 CO2 sensors.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat O2 range does it measure?\u003c\/summary\u003e\n        \u003cp\u003eIt measures oxygen concentration from 0 to 25%.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhen does it switch to red visual alarm?\u003c\/summary\u003e\n        \u003cp\u003eWhen the concentration drops below 19.5% O2.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2m-download-grid\"\u003e\n        \u003ca class=\"ibo2m-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/O2_Mk9_Sensor_1142_en_db_LogiCO2.pdf?v=1776184711\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eO2 Mk9 Sensor datasheet\u003c\/a\u003e\n        \u003ca class=\"ibo2m-btn\" href=\"https:\/\/www.logico2.com\/products\/o2-sensor-mk9\/\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOfficial product page\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-related\"\u003e\n      \u003ch2\u003eYou may also be interested in\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2m-related-grid\"\u003e\n        \u003ca class=\"ibo2m-btn\" href=\"\/en\/collections\/logico2-detectores-co2-seguridad-industrial-horeca\"\u003eLogiCO2 products\u003c\/a\u003e\n        \u003ca class=\"ibo2m-btn\" href=\"\/en\/pages\/servicio-tecnico\"\u003eTechnical advice and installation\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57365628518748,"sku":"LG012","price":790.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/mk9-o2sensor-cab-logico2.webp?v=1776207536","url":"https:\/\/installbeer.com\/en\/products\/o2-sensor-module-logico2-mk9","provider":"Install Beer","version":"1.0","type":"link"}