{"product_id":"conjunto-detector-o2-logico2-mk9-central-alarma","title":"LogiCO2 Mk9 O2 sensor set with control unit and alarm","description":"\u003csection class=\"iblgo2-product iblgo2-2057\" data-brand=\"LogiCO2\" data-model=\"O2 Mk9 Detector Base SET\"\u003e\n  \u003cstyle\u003e\n    .iblgo2-product{\n      --ib-max:1120px;\n      --ib-text:#1f2328;\n      --ib-muted:#5b6573;\n      --ib-line:#e6e8eb;\n      --ib-soft:#f7f8fa;\n      --ib-soft2:#f2f4f6;\n      --ib-accent:#111111;\n      --ib-radius:18px;\n      --ib-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ib-content-size:16px;\n      --ib-content-lh:1.68;\n      --ib-h2-size:28px;\n      --ib-h3-size:20px;\n      color:var(--ib-text);\n      font-size:var(--ib-content-size);\n      line-height:var(--ib-content-lh);\n    }\n    .iblgo2-product *{box-sizing:border-box}\n    .iblgo2-wrap{max-width:var(--ib-max);margin:0 auto;padding:4px 0 36px}\n    .iblgo2-hero,.iblgo2-block,.iblgo2-specs,.iblgo2-faq,.iblgo2-downloads,.iblgo2-related{\n      background:#fff;border:1px solid var(--ib-line);border-radius:var(--ib-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ib-shadow)\n    }\n    .iblgo2-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ib-line);\n      border-radius:999px;background:var(--ib-soft);color:var(--ib-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblgo2-product h2{\n      font-size:var(--ib-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ib-accent)\n    }\n    .iblgo2-product h3{\n      font-size:var(--ib-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ib-accent)\n    }\n    .iblgo2-product p{margin:0 0 14px;font-size:var(--ib-content-size);line-height:var(--ib-content-lh)}\n    .iblgo2-product p:last-child{margin-bottom:0}\n    .iblgo2-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ib-soft);border:1px solid var(--ib-line)\n    }\n    .iblgo2-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblgo2-card{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:var(--ib-soft)\n    }\n    .iblgo2-card strong{display:block;margin-bottom:6px;color:var(--ib-accent)}\n    .iblgo2-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ib-accent);\n      background:var(--ib-soft2);border-radius:12px\n    }\n    .iblgo2-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblgo2-list-grid li{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:#fff\n    }\n    .iblgo2-list-grid li strong{display:block;margin-bottom:6px}\n    .iblgo2-bullets{margin:0;padding-left:18px}\n    .iblgo2-bullets li{margin:0 0 10px}\n    .iblgo2-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblgo2-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ib-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblgo2-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ib-accent)\n    }\n    .iblgo2-table thead th{\n      background:var(--ib-soft2);color:var(--ib-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);font-size:15px\n    }\n    .iblgo2-table tbody th,.iblgo2-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblgo2-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ib-accent)}\n    .iblgo2-table tbody tr:last-child th,.iblgo2-table tbody tr:last-child td{border-bottom:none}\n    .iblgo2-download-grid,.iblgo2-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblgo2-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ib-accent);text-decoration:none;color:var(--ib-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblgo2-btn:hover{transform:translateY(-1px);box-shadow:var(--ib-shadow)}\n    .iblgo2-faq details{\n      border:1px solid var(--ib-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblgo2-faq details:last-child{margin-bottom:0}\n    .iblgo2-faq summary{cursor:pointer;font-weight:700;color:var(--ib-accent)}\n    .iblgo2-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblgo2-cards,.iblgo2-list-grid,.iblgo2-download-grid,.iblgo2-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblgo2-product{\n        --ib-content-size:15px;\n        --ib-h2-size:23px;\n        --ib-h3-size:18px;\n      }\n      .iblgo2-hero,.iblgo2-block,.iblgo2-specs,.iblgo2-faq,.iblgo2-downloads,.iblgo2-related{\n        padding:18px;border-radius:16px\n      }\n      .iblgo2-table{min-width:100%;border:0}\n      .iblgo2-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblgo2-table,.iblgo2-table tbody,.iblgo2-table tr,.iblgo2-table th,.iblgo2-table td{\n        display:block;width:100%\n      }\n      .iblgo2-table tr{\n        border:1px solid var(--ib-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblgo2-table tbody th{\n        background:var(--ib-soft2);border-bottom:1px solid var(--ib-line)\n      }\n      .iblgo2-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblgo2-wrap\"\u003e\n    \u003cdiv class=\"iblgo2-hero\"\u003e\n      \u003cdiv class=\"iblgo2-kicker\"\u003eO2 Safety · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 Mk9 O2 detector for monitoring unsafe oxygen levels\u003c\/h2\u003e\n      \u003cp class=\"iblgo2-snippet\"\u003e\u003cstrong\u003eThe LogiCO2 Mk9 O2 detector set integrates an optical sensor, central unit and sounder\/beacon to detect unsafe oxygen levels in enclosed spaces with nitrogen or other asphyxiant gases and provide visual and audible warning.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eWhat this product offers\u003c\/h2\u003e\n      \u003cp\u003eThis system is designed to monitor areas where the oxygen level may fall below a safe threshold. It is especially suitable for technical rooms, cold rooms, enclosures with nitrogen, nitrogen generators, nitrogen tanks, and areas with gas mixed with nitrogen.\u003c\/p\u003e\n      \u003cp\u003eCompared with standalone devices, this set already includes the Mk9 O2 sensor, Mk9 central unit, strobe sounder\/beacon, power supply, connectors, cabling and signage. This makes an initial implementation more orderly and enables centralized system monitoring.\u003c\/p\u003e\n      \u003cp\u003eThe sensor uses optical detection, includes temperature and pressure compensation, benefits from automatic self‑calibration, and shows the current O2 concentration and operating hours on its backlit display.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-cards\"\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          2057\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG008\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eBase configuration\u003c\/strong\u003e\n          1 sensor + 1 central unit + 1 sounder\/beacon\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eDefault alarm\u003c\/strong\u003e\n          \u003c19.5% O2\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eCommunication\u003c\/strong\u003e\n          RS485 Modbus\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eSystem expansion\u003c\/strong\u003e\n          Up to 8 sensors\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblgo2-note\"\u003e\n        \u003cstrong\u003eImportant:\u003c\/strong\u003e this product is not for detecting CO2. It is designed to monitor oxygen levels in enclosed spaces with a risk of O2-deficient atmosphere, especially where nitrogen or asphyxiant gases are used.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"iblgo2-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eComplete O2 safety system\u003c\/strong\u003e Includes sensor, control unit, sounder\/beacon, power supply, connectors, signs, and manual.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLong-life optical sensor\u003c\/strong\u003e LogiCO2 avoids traditional electrochemical cells and uses optical detection with self-calibration.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCentralized monitoring\u003c\/strong\u003e The central unit displays O2 values, alarms and the sensor that originates the incident.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eVisual and audible alarm\u003c\/strong\u003e The central unit and the sounder\/beacon warn when unsafe oxygen levels are reached.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUp to 8 sensors\u003c\/strong\u003e The system can be expanded with O2 Mk9 sensors and also supports CO2 Mk9 or Mk90 sensors as described in the manual.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAltitude compensation\u003c\/strong\u003e The sensor features altitude compensation.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBreathing-height installation\u003c\/strong\u003e Designed to be mounted 150 to 180 cm above the floor.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eProfessional indoor use\u003c\/strong\u003e Intended for enclosed spaces where an O2 deficit may compromise safety.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-table-wrap\"\u003e\n        \u003ctable class=\"iblgo2-table\"\u003e\n          \u003ccaption\u003eConfirmed technical specifications of the LogiCO2 Mk9 O2 detector set\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eO2 Mk9 Detector Base SET\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG008\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e2057\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003eO2 safety system with remote sensor, central unit and strobe sounder\/beacon\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSet configuration\u003c\/th\u003e\n              \u003ctd\u003eO2 Mk9 Sensor + Mk9 Central Unit + Amber LED Horn\/Strobe + transformer + wiring + signage\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eNumber of sensors\u003c\/th\u003e\n              \u003ctd\u003e1–8\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSystem power supply\u003c\/th\u003e\n              \u003ctd\u003e12–24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor power supply\u003c\/th\u003e\n              \u003ctd\u003e24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor consumption\u003c\/th\u003e\n              \u003ctd\u003e\u003c30 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWiring connections\u003c\/th\u003e\n              \u003ctd\u003eRJ45\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eInterfaz digital\u003c\/th\u003e\n              \u003ctd\u003eRS485 Modbus serial port\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor outputs\u003c\/th\u003e\n              \u003ctd\u003e2 x 24 V DC transistor outputs, min. 1 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor display\u003c\/th\u003e\n              \u003ctd\u003eGráfica 128x64, retroiluminada\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit display\u003c\/th\u003e\n              \u003ctd\u003eGráfica 128x64, retroiluminada\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor audible signal\u003c\/th\u003e\n              \u003ctd\u003e76 dBA (1 m) max.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit audible signal\u003c\/th\u003e\n              \u003ctd\u003eThe manual describes an internal audible warning; sound level not specified in the product sheet\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating principle\u003c\/th\u003e\n              \u003ctd\u003eOptical FB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eO2 measuring range\u003c\/th\u003e\n              \u003ctd\u003e0–100% vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eO2 accuracy\u003c\/th\u003e\n              \u003ctd\u003e\u003c2% FS\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDefault alarm\u003c\/th\u003e\n              \u003ctd\u003e\u003c19.5% O2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAjuste adicional\u003c\/th\u003e\n              \u003ctd\u003eCompensación de altitud\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor ambient temperature\u003c\/th\u003e\n              \u003ctd\u003eFrom -20 to +40 °C. Indoor use only.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensiones del sensor\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor protection\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza tensión nominal\u003c\/th\u003e\n              \u003ctd\u003e18-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSounder\/beacon average current\u003c\/th\u003e\n              \u003ctd\u003e120 mA at 24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eHorn\/strobe decibels\u003c\/th\u003e\n              \u003ctd\u003e110 dB \/ 1 m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSounder\/beacon flash intensity\u003c\/th\u003e\n              \u003ctd\u003e115 cd\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eHorn\/strobe flash frequency\u003c\/th\u003e\n              \u003ctd\u003e65\/min\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSounder\/beacon ambient temperature\u003c\/th\u003e\n              \u003ctd\u003eFrom -5 to +50 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza dimensiones\u003c\/th\u003e\n              \u003ctd\u003e134 x 115 x 61 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSounder\/beacon protection\u003c\/th\u003e\n              \u003ctd\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit capacity\u003c\/th\u003e\n              \u003ctd\u003eUp to 8 sensors; displays O2 values and the sensor that triggers the alarm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit indicators\u003c\/th\u003e\n              \u003ctd\u003eGreen LED for operation, red LED for alarm, yellow LED for fault, silence\/reset\/test button\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003eMk9 central unit, 5 m red cable, Mk9 O2 sensor, 10 m red cable, 5 m blue cable, amber LED strobe sounder\/beacon with 1 m cable, RJ45 1-1 splitter, RJ45 1-2 splitter, 1 A power supply, UL\/CE\/AU\/UK plugs, plug lock, bag with 6 screws and plugs, Mk9 O2 safety system sign, Mk9 strobe sounder\/beacon sign, and Mk9 O2 installation manual\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGTIN\/EAN\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSA\/HS code\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThis system is used in enclosed spaces where there is a risk of unsafe oxygen concentration. The manual itself places the sensor at nitrogen distribution points, nitrogen generators, nitrogen tanks and areas with gas mixed with nitrogen.\u003c\/p\u003e\n      \u003cp\u003eIt can also be used when the asphyxiant gas is stored outside the building but enters the interior through pipes, provided that the monitored area is where the actual risk to people exists.\u003c\/p\u003e\n      \u003cp\u003eThe system can be expanded with up to eight Mk9 O2 sensors and, according to the manual, the central unit can also work with Mk9 and Mk90 CO2 sensors within the LogiCO2 architecture.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"iblgo2-bullets\"\u003e\n        \u003cli\u003eThe O2 sensor must be mounted at breathing height, between 150 and 180 cm from the floor.\u003c\/li\u003e\n        \u003cli\u003eThe sounder\/beacon must be installed above the sensor, approximately 2–2.4 m from the floor and visible from any entrance to the monitored area.\u003c\/li\u003e\n        \u003cli\u003eIt is recommended to install a second horn\/strobe outside the monitored area, preferably above the access door or doors.\u003c\/li\u003e\n        \u003cli\u003eThe central unit must be installed outside the monitored area or room, in a visible and accessible position.\u003c\/li\u003e\n        \u003cli\u003eIf the room has only mechanical ventilation, the manual states that it must have a sensor.\u003c\/li\u003e\n        \u003cli\u003eIf a nitrogen generator is used in the same area, the excess oxygen generated must be vented; the manual states that the sensor may not be used in the area if that oxygen is not extracted.\u003c\/li\u003e\n        \u003cli\u003eThe system does not operate if it is disconnected from the mains, so the power supply and its mechanical lock must be checked before commissioning.\u003c\/li\u003e\n        \u003cli\u003eAs safety equipment, installation and maintenance must be carried out only by professionals.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eThe LogiCO2 O2 sensor features automatic self-calibration enabled by default and should not require manual calibration under normal conditions, as long as it remains continuously powered. However, the manufacturer itself states that manual calibration is required at start-up.\u003c\/p\u003e\n      \u003cp\u003eIn addition, as this is a safety product, it is recommended to perform a functional check at least once a year. Cleaning should be done with water and a damp cloth, and the sensor and the central unit housing must not be opened by unauthorized personnel.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes this system detect CO2?\u003c\/summary\u003e\n        \u003cp\u003eNo. This product is designed to detect unsafe oxygen levels in enclosed spaces.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat exactly does set 2057 include?\u003c\/summary\u003e\n        \u003cp\u003eIncludes Mk9 O2 sensor, Mk9 central unit, strobe sounder\/beacon, transformer, cabling, RJ45 connectors, signage and installation manual.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhere should the O2 sensor be installed?\u003c\/summary\u003e\n        \u003cp\u003eIt must be installed at breathing height, between 150 and 180 cm from the floor, in the area where there is actually a risk of an unsafe atmosphere.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhere are the sounder\/beacon and central unit installed?\u003c\/summary\u003e\n        \u003cp\u003eThe sounder\/beacon must be placed above the sensor, about 2–2.4 m from the floor. The central unit must be mounted outside the monitored area, in a clearly visible and accessible location.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat is the default alarm level?\u003c\/summary\u003e\n        \u003cp\u003eThe manufacturer specifies a default alarm level of 19.5% O2.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Necesita mantenimiento periódico?\u003c\/summary\u003e\n        \u003cp\u003eYes. Although it has automatic self‑calibration, a functional check is recommended at least once a year and an initial manual calibration when starting up the system.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-download-grid\"\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/O2_Mk9_Detector_BaseSET_2057_es_db_LogiCO2.pdf?v=1775037461\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eLogiCO2 Datasheet 2057\u003c\/a\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/o2ss_mk9_2057_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eO2 Mk9 manual\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-related\"\u003e\n      \u003ch2\u003eTambién puede interesarte\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-related-grid\"\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"\/en\/collections\/alarmas-detectores-logico2\"\u003eLogiCO2 alarms and detectors\u003c\/a\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"\/en\/pages\/servicio-tecnico\"\u003eAsesoramiento e instalación técnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57238900572508,"sku":"LG008","price":1090.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/o2-mk9detector-set-logic2.webp?v=1775037730","url":"https:\/\/installbeer.com\/en\/products\/o2-detector-set-logico2-mk9-central-alarm","provider":"Install Beer","version":"1.0","type":"link"}