{"product_id":"kit-sensor-de-co2-logico2-mk90","title":"Additional LogiCO2 Mk90 CO2 sensor kit","description":"\u003csection class=\"ibmk90-product ibmk90-1190\" data-brand=\"LogiCO2\" data-model=\"CO2 Sensor Mk90\"\u003e\n  \u003cstyle\u003e\n    .ibmk90-product{\n      --ibmk90-max:1120px;\n      --ibmk90-text:#1f2328;\n      --ibmk90-muted:#5b6573;\n      --ibmk90-line:#e6e8eb;\n      --ibmk90-soft:#f7f8fa;\n      --ibmk90-soft2:#f2f4f6;\n      --ibmk90-accent:#111111;\n      --ibmk90-radius:18px;\n      --ibmk90-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibmk90-content-size:16px;\n      --ibmk90-content-lh:1.68;\n      --ibmk90-h2-size:28px;\n      --ibmk90-h3-size:20px;\n      color:var(--ibmk90-text);\n      font-size:var(--ibmk90-content-size);\n      line-height:var(--ibmk90-content-lh);\n    }\n    .ibmk90-product *{box-sizing:border-box}\n    .ibmk90-wrap{max-width:var(--ibmk90-max);margin:0 auto;padding:4px 0 36px}\n    .ibmk90-hero,.ibmk90-block,.ibmk90-specs,.ibmk90-faq,.ibmk90-downloads,.ibmk90-related{\n      background:#fff;border:1px solid var(--ibmk90-line);border-radius:var(--ibmk90-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibmk90-shadow)\n    }\n    .ibmk90-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibmk90-line);\n      border-radius:999px;background:var(--ibmk90-soft);color:var(--ibmk90-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibmk90-product h2{\n      font-size:var(--ibmk90-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibmk90-accent)\n    }\n    .ibmk90-product h3{\n      font-size:var(--ibmk90-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibmk90-accent)\n    }\n    .ibmk90-product p{\n      margin:0 0 14px;\n      font-size:var(--ibmk90-content-size);\n      line-height:var(--ibmk90-content-lh)\n    }\n    .ibmk90-product p:last-child{margin-bottom:0}\n    .ibmk90-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibmk90-soft);border:1px solid var(--ibmk90-line)\n    }\n    .ibmk90-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibmk90-card{\n      padding:16px;border:1px solid var(--ibmk90-line);border-radius:16px;background:var(--ibmk90-soft)\n    }\n    .ibmk90-card strong{display:block;margin-bottom:6px;color:var(--ibmk90-accent)}\n    .ibmk90-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibmk90-accent);\n      background:var(--ibmk90-soft2);border-radius:12px\n    }\n    .ibmk90-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibmk90-list-grid li{\n      padding:16px;border:1px solid var(--ibmk90-line);border-radius:16px;background:#fff\n    }\n    .ibmk90-list-grid li strong{display:block;margin-bottom:6px}\n    .ibmk90-bullets{margin:0;padding-left:18px}\n    .ibmk90-bullets li{margin:0 0 10px}\n    .ibmk90-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibmk90-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibmk90-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibmk90-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibmk90-accent)\n    }\n    .ibmk90-table thead th{\n      background:var(--ibmk90-soft2);color:var(--ibmk90-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibmk90-line);font-size:15px\n    }\n    .ibmk90-table tbody th,.ibmk90-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibmk90-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibmk90-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibmk90-accent)}\n    .ibmk90-table tbody tr:last-child th,.ibmk90-table tbody tr:last-child td{border-bottom:none}\n    .ibmk90-download-grid,.ibmk90-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibmk90-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibmk90-accent);text-decoration:none;color:var(--ibmk90-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibmk90-btn:hover{transform:translateY(-1px);box-shadow:var(--ibmk90-shadow)}\n    .ibmk90-faq details{\n      border:1px solid var(--ibmk90-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibmk90-faq details:last-child{margin-bottom:0}\n    .ibmk90-faq summary{cursor:pointer;font-weight:700;color:var(--ibmk90-accent)}\n    .ibmk90-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibmk90-cards,.ibmk90-list-grid,.ibmk90-download-grid,.ibmk90-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibmk90-product{\n        --ibmk90-content-size:15px;\n        --ibmk90-h2-size:23px;\n        --ibmk90-h3-size:18px;\n      }\n      .ibmk90-hero,.ibmk90-block,.ibmk90-specs,.ibmk90-faq,.ibmk90-downloads,.ibmk90-related{\n        padding:18px;border-radius:16px\n      }\n      .ibmk90-table{min-width:100%;border:0}\n      .ibmk90-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibmk90-table,.ibmk90-table tbody,.ibmk90-table tr,.ibmk90-table th,.ibmk90-table td{\n        display:block;width:100%\n      }\n      .ibmk90-table tr{\n        border:1px solid var(--ibmk90-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibmk90-table tbody th{\n        background:var(--ibmk90-soft2);border-bottom:1px solid var(--ibmk90-line)\n      }\n      .ibmk90-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibmk90-wrap\"\u003e\n    \u003cdiv class=\"ibmk90-hero\"\u003e\n      \u003cdiv class=\"ibmk90-kicker\"\u003eCO2 sensor · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 Mk90 CO2 sensor to extend or replace a detection point\u003c\/h2\u003e\n      \u003cp class=\"ibmk90-snippet\"\u003e\u003cstrong\u003eThe LogiCO2 Mk90 CO2 sensor is a detection module with integrated audible and visual alarm that measures CO2 concentration in confined spaces and connects to the Mk9 central unit within the LogiCO2 safety system.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eWhat this product offers\u003c\/h2\u003e\n      \u003cp\u003eThis product is intended to expand an existing installation or replace an Mk90 sensor within a LogiCO2 system. It is not a complete kit with control unit, siren\/beacon and power supply, but the sensor module only.\u003c\/p\u003e\n      \u003cp\u003eIts main advantage over a basic sensor is the Mk90 construction itself: translucent housing, high‑intensity red alarm LEDs, local audible indication and LCD display showing CO2, TWA and temperature when the thermal alarm is active.\u003c\/p\u003e\n      \u003cp\u003eAt Install Beer, as official distributors in Europe and technical service for installation and maintenance, this type of module is particularly suitable for extensions, replacements and maintenance of already installed LogiCO2 systems.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"ibmk90-cards\"\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eManufacturer’s part number\u003c\/strong\u003e\n          1190\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG015\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eType\u003c\/strong\u003e\n          CO2 sensor for Mk9 system\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eMeasuring range\u003c\/strong\u003e\n          0–3% vol.\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eOn-screen display\u003c\/strong\u003e\n          Up to 6.7% vol.\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibmk90-card\"\u003e\n          \u003cstrong\u003eProtection\u003c\/strong\u003e\n          IP54\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"ibmk90-note\"\u003e\n        \u003cstrong\u003eImportant:\u003c\/strong\u003e the official page states that the package includes the Mk90 sensor. Before purchasing, it is advisable to confirm whether your replacement or expansion also requires cabling, central unit, siren\/beacon or other system accessories.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"ibmk90-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBuilt‑in alarm\u003c\/strong\u003e The sensor includes audible and visual indication instead of relying solely on the control unit.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHigh‑intensity red LEDs\u003c\/strong\u003e The Mk90 adds enhanced visual warning thanks to its translucent housing and visible alarm LEDs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLCD display\u003c\/strong\u003e Shows current CO2 concentration, TWA, and temperature if the temperature function is enabled.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eNDIR detection\u003c\/strong\u003e Uses non-dispersive infrared and a thermistor to measure CO2.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eProfessional communication\u003c\/strong\u003e Integrates via RS485 Modbus within the LogiCO2 system.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eConfigurable address\u003c\/strong\u003e The manual allows ID configuration from 1 to 12 via DIP switches.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAutomatic self‑calibration\u003c\/strong\u003e Reduces annual zero‑point drift and helps maintain reading stability.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLong service life\u003c\/strong\u003e The manual states a sensor life of more than 15 years.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"ibmk90-table-wrap\"\u003e\n        \u003ctable class=\"ibmk90-table\"\u003e\n          \u003ccaption\u003eConfirmed technical specifications of the LogiCO2 Mk90 CO2 sensor\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eConfirmed data\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eCO2 Sensor Mk90\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG015\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ manufacturer part number\u003c\/th\u003e\n              \u003ctd\u003e1190\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003eCO2 sensor for LogiCO2 safety system\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCompatibility\u003c\/th\u003e\n              \u003ctd\u003eConnectable with Mk9 Central Unit and Mk9 CO2 Sensor Set\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFuente de alimentación\u003c\/th\u003e\n              \u003ctd\u003e24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConsumption without alarm\u003c\/th\u003e\n              \u003ctd\u003e56 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePower consumption in alarm\u003c\/th\u003e\n              \u003ctd\u003e117 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWiring connections\u003c\/th\u003e\n              \u003ctd\u003eRJ45\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDigital interface\u003c\/th\u003e\n              \u003ctd\u003eRS485 Modbus serial port\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOutputs\u003c\/th\u003e\n              \u003ctd\u003e2 x 24 V DC transistor outputs, min. 1 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n              \u003ctd\u003eLCD\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSound signal level\u003c\/th\u003e\n              \u003ctd\u003e80 dBa (1 m) max.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating principle\u003c\/th\u003e\n              \u003ctd\u003eNon-dispersive infrared (NDIR) and thermistor\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCO2 measuring range\u003c\/th\u003e\n              \u003ctd\u003e0–3% vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOn-screen display\u003c\/th\u003e\n              \u003ctd\u003eCurrent CO2 concentration from 0.0% to 6.7%, TWA and temperature if the thermal alarm is enabled\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAccuracy\u003c\/th\u003e\n              \u003ctd\u003e±200 ppm ±10% of reading\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n              \u003ctd\u003e0,01 % vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAnnual zero-point drift\u003c\/th\u003e\n              \u003ctd\u003e\u003c0.01% vol. with automatic self-calibration function\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n              \u003ctd\u003e0 to +45 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating humidity\u003c\/th\u003e\n              \u003ctd\u003e0 to 95% RH non-condensing\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWarm‑up time\u003c\/th\u003e\n              \u003ctd\u003e1 minute at 22 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor service life\u003c\/th\u003e\n              \u003ctd\u003e\u003e15 años\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOvervoltage\u003c\/th\u003e\n              \u003ctd\u003eCategory II\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePollution degree\u003c\/th\u003e\n              \u003ctd\u003eII\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePreset levels\u003c\/th\u003e\n              \u003ctd\u003eAwareness \u003e5000 ppm, low alarm 1.5%, high alarm 3%, TWA 5000 ppm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003eCO2 Sensor Mk90\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n              \u003ctd\u003e1 Kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThis sensor is designed to be integrated into the LogiCO2 safety system with Mk9 central unit and sensor ID configurations. It is suitable as a spare or extension when a CO2 safety installation is already in operation.\u003c\/p\u003e\n      \u003cp\u003eIt is suitable for hospitality, wineries, breweries, cold rooms, technical rooms and other confined spaces where CO2 is used or stored and an additional detection point or replacement of an existing sensor is needed.\u003c\/p\u003e\n      \u003cp\u003eIt is also a useful option when you want to maintain the same LogiCO2 architecture and the same local alert logic in the sensor itself.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"ibmk90-bullets\"\u003e\n        \u003cli\u003eThe manual states that the sensor should be installed at a maximum height of 30 cm from the floor.\u003c\/li\u003e\n        \u003cli\u003eIt must be installed at a maximum distance of 5 m from the CO2 distribution point or potential leak source.\u003c\/li\u003e\n        \u003cli\u003eEach sensor covers a maximum area of 78 m² in an enclosed space.\u003c\/li\u003e\n        \u003cli\u003eIt is advisable to mount the sensor in an area where it is less likely to be hit by moving objects, boxes, or cleaning equipment.\u003c\/li\u003e\n        \u003cli\u003eIf the system includes a siren\/beacon, it must be mounted above the sensor, approximately 2–2.4 m from the floor and clearly visible from the entrance.\u003c\/li\u003e\n        \u003cli\u003eBefore purchasing, confirm whether you need only the sensor or a complete set with central unit, beacon, and power supply.\u003c\/li\u003e\n        \u003cli\u003eAs it is a safety component, installation and functional testing must be carried out with proper technical judgment.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eThe manual recommends performing a functional check at least once a year, precisely because this is a safety product.\u003c\/p\u003e\n      \u003cp\u003eIn real‑world use, it is advisable to periodically check the displayed reading, LED operation, audible signal, and correct integration with the rest of the system, especially after replacing the sensor or changing its ID address.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIs this product a complete CO2 alarm kit?\u003c\/summary\u003e\n        \u003cp\u003eNo. It is the Mk90 sensor, designed to be integrated into a LogiCO2 system with Mk9 central unit or as a replacement within an existing installation.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhich system is it compatible with?\u003c\/summary\u003e\n        \u003cp\u003eThe official page indicates compatibility with the Mk9 central unit and the Mk9 CO2 Sensor Set.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat exactly does it measure?\u003c\/summary\u003e\n        \u003cp\u003eMeasures CO2 concentration and displays on screen the current concentration, TWA and temperature when the thermal alarm is active.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat are the default alarm levels?\u003c\/summary\u003e\n        \u003cp\u003eBy default, the manual specifies awareness \u003e5000 ppm, low alarm 1.5%, high alarm 3%, and TWA 5000 ppm.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Dónde debe instalarse?\u003c\/summary\u003e\n        \u003cp\u003eIt must be installed at a maximum of 30 cm from the floor and less than 5 m from the distribution point or potential CO2 leak source.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes it require periodic maintenance?\u003c\/summary\u003e\n        \u003cp\u003eYes. The manufacturer recommends at least one functional check per year.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"ibmk90-download-grid\"\u003e\n        \u003ca class=\"ibmk90-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMk9 \/ Mk90 manual in Spanish\u003c\/a\u003e\n        \u003ca class=\"ibmk90-btn\" href=\"https:\/\/youtu.be\/1trr3C-eVzs?si=LL6plrbHB_LvbH3o\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eVídeo tutorial Mk9 \/ Mk90\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibmk90-related\"\u003e\n      \u003ch2\u003eYou may also be interested in\u003c\/h2\u003e\n      \u003cdiv class=\"ibmk90-related-grid\"\u003e\n        \u003ca class=\"ibmk90-btn\" href=\"\/en\/collections\/logico2-detectores-co2-seguridad-industrial-horeca\"\u003eLogiCO2 products\u003c\/a\u003e\n        \u003ca class=\"ibmk90-btn\" href=\"\/en\/pages\/servicio-tecnico\"\u003eTechnical advice and installation\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57365629829468,"sku":"LG015","price":314.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/mk90-co2sensor-alarm-logico2.webp?v=1775040741","url":"https:\/\/installbeer.com\/en\/products\/co2-sensor-kit-logico2-mk90","provider":"Install Beer","version":"1.0","type":"link"}