{"product_id":"controlador-enriquecimiento-co2-logico2-grow-cultivo-invernadero","title":"LogiCO2 Grow CO2 enrichment controller for grow rooms and greenhouses","description":"\u003csection class=\"ibgrow-product ibgrow-2029\" data-brand=\"LogiCO2\" data-model=\"Grow CO2 Enrichment Controller Base SET\"\u003e\n  \u003cstyle\u003e\n    .ibgrow-product{\n      --ibgrow-max:1120px;\n      --ibgrow-text:#1f2328;\n      --ibgrow-muted:#5b6573;\n      --ibgrow-line:#e6e8eb;\n      --ibgrow-soft:#f7f8fa;\n      --ibgrow-soft2:#f2f4f6;\n      --ibgrow-accent:#111111;\n      --ibgrow-radius:18px;\n      --ibgrow-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibgrow-content-size:16px;\n      --ibgrow-content-lh:1.68;\n      --ibgrow-h2-size:28px;\n      --ibgrow-h3-size:20px;\n      color:var(--ibgrow-text);\n      font-size:var(--ibgrow-content-size);\n      line-height:var(--ibgrow-content-lh);\n    }\n    .ibgrow-product *{box-sizing:border-box}\n    .ibgrow-wrap{max-width:var(--ibgrow-max);margin:0 auto;padding:4px 0 36px}\n    .ibgrow-hero,.ibgrow-block,.ibgrow-specs,.ibgrow-faq,.ibgrow-downloads,.ibgrow-related{\n      background:#fff;border:1px solid var(--ibgrow-line);border-radius:var(--ibgrow-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibgrow-shadow)\n    }\n    .ibgrow-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibgrow-line);\n      border-radius:999px;background:var(--ibgrow-soft);color:var(--ibgrow-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibgrow-product h2{\n      font-size:var(--ibgrow-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibgrow-accent)\n    }\n    .ibgrow-product h3{\n      font-size:var(--ibgrow-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibgrow-accent)\n    }\n    .ibgrow-product p{\n      margin:0 0 14px;\n      font-size:var(--ibgrow-content-size);\n      line-height:var(--ibgrow-content-lh)\n    }\n    .ibgrow-product p:last-child{margin-bottom:0}\n    .ibgrow-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibgrow-soft);border:1px solid var(--ibgrow-line)\n    }\n    .ibgrow-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibgrow-card{\n      padding:16px;border:1px solid var(--ibgrow-line);border-radius:16px;background:var(--ibgrow-soft)\n    }\n    .ibgrow-card strong{display:block;margin-bottom:6px;color:var(--ibgrow-accent)}\n    .ibgrow-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibgrow-accent);\n      background:var(--ibgrow-soft2);border-radius:12px\n    }\n    .ibgrow-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibgrow-list-grid li{\n      padding:16px;border:1px solid var(--ibgrow-line);border-radius:16px;background:#fff\n    }\n    .ibgrow-list-grid li strong{display:block;margin-bottom:6px}\n    .ibgrow-bullets{margin:0;padding-left:18px}\n    .ibgrow-bullets li{margin:0 0 10px}\n    .ibgrow-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibgrow-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibgrow-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibgrow-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibgrow-accent)\n    }\n    .ibgrow-table thead th{\n      background:var(--ibgrow-soft2);color:var(--ibgrow-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibgrow-line);font-size:15px\n    }\n    .ibgrow-table tbody th,.ibgrow-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibgrow-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibgrow-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibgrow-accent)}\n    .ibgrow-table tbody tr:last-child th,.ibgrow-table tbody tr:last-child td{border-bottom:none}\n    .ibgrow-download-grid,.ibgrow-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibgrow-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibgrow-accent);text-decoration:none;color:var(--ibgrow-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibgrow-btn:hover{transform:translateY(-1px);box-shadow:var(--ibgrow-shadow)}\n    .ibgrow-faq details{\n      border:1px solid var(--ibgrow-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibgrow-faq details:last-child{margin-bottom:0}\n    .ibgrow-faq summary{cursor:pointer;font-weight:700;color:var(--ibgrow-accent)}\n    .ibgrow-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibgrow-cards,.ibgrow-list-grid,.ibgrow-download-grid,.ibgrow-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibgrow-product{\n        --ibgrow-content-size:15px;\n        --ibgrow-h2-size:23px;\n        --ibgrow-h3-size:18px;\n      }\n      .ibgrow-hero,.ibgrow-block,.ibgrow-specs,.ibgrow-faq,.ibgrow-downloads,.ibgrow-related{\n        padding:18px;border-radius:16px\n      }\n      .ibgrow-table{min-width:100%;border:0}\n      .ibgrow-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibgrow-table,.ibgrow-table tbody,.ibgrow-table tr,.ibgrow-table th,.ibgrow-table td{\n        display:block;width:100%\n      }\n      .ibgrow-table tr{\n        border:1px solid var(--ibgrow-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibgrow-table tbody th{\n        background:var(--ibgrow-soft2);border-bottom:1px solid var(--ibgrow-line)\n      }\n      .ibgrow-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibgrow-wrap\"\u003e\n    \u003cdiv class=\"ibgrow-hero\"\u003e\n      \u003cdiv class=\"ibgrow-kicker\"\u003eGrow and greenhouse · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 Grow CO2 enrichment controller for grow rooms and greenhouses\u003c\/h2\u003e\n      \u003cp class=\"ibgrow-snippet\"\u003e\u003cstrong\u003eThe LogiCO2 Grow CO2 enrichment controller measures the ambient CO2 concentration and opens or closes a valve or burner to maintain the target level in grow rooms and greenhouses.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibgrow-block\"\u003e\n      \u003ch2\u003eQué aporta este producto\u003c\/h2\u003e\n      \u003cp\u003eThis controller is designed to regulate CO2 enrichment in indoor grow rooms and greenhouses. Its function is to measure the ambient concentration and act on the CO2 supply system to approach the configured target value.\u003c\/p\u003e\n      \u003cp\u003eIt is particularly suitable for projects where a more stable and automated dosing is required than simply opening the gas manually. The system can operate with a plug \u0026 play enrichment valve or, if the CO2 is generated by combustion, with an RCB relay box to start and stop the burner.\u003c\/p\u003e\n      \u003cp\u003eIt also incorporates an internal light sensor to activate control only when plant lighting is on, a useful feature to optimize consumption and avoid unnecessary CO2 supply outside the photosynthesis period.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibgrow-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"ibgrow-cards\"\u003e\n        \u003cdiv class=\"ibgrow-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          2029\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibgrow-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG009\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibgrow-card\"\u003e\n          \u003cstrong\u003eApplication\u003c\/strong\u003e\n          Grow room and greenhouse\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibgrow-card\"\u003e\n          \u003cstrong\u003eMeasuring range\u003c\/strong\u003e\n          0–5000 ppm CO2\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibgrow-card\"\u003e\n          \u003cstrong\u003eAdjustable setpoint\u003c\/strong\u003e\n          From 700 to 2000 ppm\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibgrow-card\"\u003e\n          \u003cstrong\u003eDefault target value\u003c\/strong\u003e\n          1200 ppm\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"ibgrow-note\"\u003e\n        \u003cstrong\u003eImportant:\u003c\/strong\u003e this product is a enrichment controller, not a personal safety alarm. The manufacturer itself envisages its use together with a LogiCO2 Safety CO2 Mk9 system when both crop efficiency and safety monitoring are required.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibgrow-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"ibgrow-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAutomatic CO2 control\u003c\/strong\u003e Measures ambient concentration and actuates the enrichment element to approach the configured setpoint.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBuilt-in light sensor\u003c\/strong\u003e It can activate control only when the greenhouse lighting is on. This function can be disabled by DIP switch.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAdjustable setpoint\u003c\/strong\u003e Allows you to set the target concentration between 700 and 2000 ppm in 50 ppm steps.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOptional adaptive control\u003c\/strong\u003e Can automatically adjust the dosing time between 10 and 120 seconds every 5 minutes.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eValve or burner compatibility\u003c\/strong\u003e Works with enrichment valve 0475 and, via RCB box 0471, can also control burners or fans.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eClear on-screen reading\u003c\/strong\u003e Alternately displays current concentration, target setpoint, and altitude setting.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLow-level indicator\u003c\/strong\u003e It can display “Low” when the concentration is 200 ppm below the target, a useful indication if the CO2 cylinder is empty.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLogiCO2 integration\u003c\/strong\u003e Can be connected to a LogiCO2 Safety CO2 Mk9 central unit to display the concentration also on the central.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibgrow-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"ibgrow-table-wrap\"\u003e\n        \u003ctable class=\"ibgrow-table\"\u003e\n          \u003ccaption\u003eConfirmed technical specifications of the LogiCO2 Grow CO2 enrichment controller\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eGrow CO2 Enrichment Controller Base SET\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG009\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e2029\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003eCO2 enrichment controller for indoor growing and greenhouses\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n              \u003ctd\u003eGrow room and greenhouse\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating principle\u003c\/th\u003e\n              \u003ctd\u003eMeasures ambient CO2 concentration and opens\/closes the enrichment valve or controls a burner via external relay\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment power supply\u003c\/th\u003e\n              \u003ctd\u003e24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePlug-in power supply\u003c\/th\u003e\n              \u003ctd\u003eInput 100–240 V AC, 50\/60 Hz, max. 0.5 A · Output 24 V DC, max. 1.0 A\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n              \u003ctd\u003e130 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePower consumption with enrichment valve 10 W\u003c\/th\u003e\n              \u003ctd\u003eMax. 550 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMeasuring range\u003c\/th\u003e\n              \u003ctd\u003e0–5000 ppm CO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAdjustable setpoint\u003c\/th\u003e\n              \u003ctd\u003eFrom 700 to 2000 ppm, in 50 ppm steps\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDefault setpoint\u003c\/th\u003e\n              \u003ctd\u003e1200 ppm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eControl deactivation\u003c\/th\u003e\n              \u003ctd\u003e“OFF” setpoint\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eHysteresis\u003c\/th\u003e\n              \u003ctd\u003e40 or 100 ppm; default value 40 ppm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAdaptive control\u003c\/th\u003e\n              \u003ctd\u003eAutomatic dosing from 10 to 120 seconds every 5 minutes; initial time 30 seconds\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFixed default dosing\u003c\/th\u003e\n              \u003ctd\u003e30 or 60 seconds every 5 minutes\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSerial communication\u003c\/th\u003e\n              \u003ctd\u003eModbus over RS485\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLight sensor\u003c\/th\u003e\n              \u003ctd\u003eInternal; allows control to be activated only when the light is on\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAltitude compensation\u003c\/th\u003e\n              \u003ctd\u003eCalibrated for altitudes up to 5000 m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCalibración automática\u003c\/th\u003e\n              \u003ctd\u003eAt regular intervals\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura de funcionamiento\u003c\/th\u003e\n              \u003ctd\u003eCalibrated for 0 to 45 °C; the sensor operates from -20 °C, but values are valid only between 0 and 45 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eHumedad de funcionamiento\u003c\/th\u003e\n              \u003ctd\u003e0–95% RH non-condensing\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n              \u003ctd\u003e-40 to +70 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtección contra penetración\u003c\/th\u003e\n              \u003ctd\u003eIP56\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eInstallation\u003c\/th\u003e\n              \u003ctd\u003eIndoor use only\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLED indicators\u003c\/th\u003e\n              \u003ctd\u003eRed: alarm for concentration above 5000 ppm · Green: supplying CO2 · Green: unit powered on\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConnections\u003c\/th\u003e\n              \u003ctd\u003eBlue cable for enrichment valve and\/or RCB box · red cable for communication and power · RJ45 connectors\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003eGrow CO2 Enrichment Controller + 5 m power\/communication cable + power supply with cable + plug lock + 10 m signalling cable + 1 RJ45 1-1 connector + manual + Grow sign and collar seals\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConfirmed optional accessories\u003c\/th\u003e\n              \u003ctd\u003e0475 enrichment valve with filter · 0471 RCB box for fan or burner control\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGTIN\/EAN\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCódigo SA\/HS\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibgrow-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThis controller is used in grow rooms, grow cabinets, propagation areas and greenhouses where the atmosphere is enriched with CO2 to promote photosynthesis.\u003c\/p\u003e\n      \u003cp\u003eIt is compatible with the LogiCO2 0475 enrichment valve and with the RCB 0471 box for fan control or for starting and stopping CO2 generation burners. Both the valve and the RCB use RJ45 connectors for direct connection to the controller.\u003c\/p\u003e\n      \u003cp\u003eIt can also be connected to a LogiCO2 Safety CO2 Mk9 central unit. In that case, the central can display the CO2 concentration and the “\/Low” indication when the current level is 200 ppm below the target.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibgrow-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"ibgrow-bullets\"\u003e\n        \u003cli\u003eMount the controller at the same height as the plant foliage, where photosynthesis is actually taking place.\u003c\/li\u003e\n        \u003cli\u003eIf grow lighting is used, make sure the light reaches the controller so that the internal light sensor can operate correctly.\u003c\/li\u003e\n        \u003cli\u003eAvoid spraying water directly onto the equipment.\u003c\/li\u003e\n        \u003cli\u003eBefore purchasing, confirm whether you need only the controller or also the enrichment valve 0475 or the RCB 0471 box, because they are accessories and not part of the base kit.\u003c\/li\u003e\n        \u003cli\u003eThe blue cable is used for the enrichment valve and\/or for the RCB; the red cable is for power supply and communication.\u003c\/li\u003e\n        \u003cli\u003eUse the protective gaskets and collar seals to protect RJ45 connectors and splitters from moisture and dust.\u003c\/li\u003e\n        \u003cli\u003eThe power supply must be mounted with the included plug lock to prevent disconnection without tools.\u003c\/li\u003e\n        \u003cli\u003eIf the project also requires safety monitoring for people, consider integration with a LogiCO2 Safety CO2 Mk9 system.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibgrow-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eThe unit performs automatic calibration at regular intervals. Even so, it is advisable to periodically check the condition of the cables, connectors, LEDs, power supply and the response of the CO2 control to ensure stable regulation.\u003c\/p\u003e\n      \u003cp\u003eIn real use it is also advisable to check that the chosen setpoint, hysteresis and adaptive mode match the crop strategy. If the unit shows “Low”, it may indicate that the CO2 cylinder is empty or that the gas supply is insufficient for the configured target.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibgrow-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes this product measure CO2 or does it only open a valve?\u003c\/summary\u003e\n        \u003cp\u003eIt measures the ambient CO2 concentration and, based on that reading, opens or closes the enrichment system to approach the setpoint.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes it include the enrichment valve?\u003c\/summary\u003e\n        \u003cp\u003eNo. Valve 0475 is an optional accessory. The base kit includes the controller, power supply, cables, connector, Grow sign and manual.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCan it be used with a burner instead of a valve?\u003c\/summary\u003e\n        \u003cp\u003eYes. If the CO2 is generated by combustion, the manufacturer specifies using the RCB 0471 box to start and stop the burner instead of the enrichment valve.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhere should the controller be installed?\u003c\/summary\u003e\n        \u003cp\u003eIt must be mounted at the same height as the plant foliage. If grow lighting is used, the light must reach the unit so that the internal light sensor can operate correctly.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat setpoint range does it allow?\u003c\/summary\u003e\n        \u003cp\u003eYou can set the target concentration between 700 and 2000 ppm in 50 ppm steps. The default value is 1200 ppm.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCan it be connected to a LogiCO2 safety system?\u003c\/summary\u003e\n        \u003cp\u003eYes. It can be connected to a LogiCO2 Safety CO2 Mk9 central unit to combine enrichment control and display from the central unit.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibgrow-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"ibgrow-download-grid\"\u003e\n        \u003ca class=\"ibgrow-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/grow_co2_enrichment_controller.pdf?v=1775039254\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eLogiCO2 Grow CO2 Enrichment Controller Manual\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibgrow-related\"\u003e\n      \u003ch2\u003eTambién puede interesarte\u003c\/h2\u003e\n      \u003cdiv class=\"ibgrow-related-grid\"\u003e\n        \u003ca class=\"ibgrow-btn\" href=\"\/en\/collections\/logico2\"\u003eLogiCO2 products\u003c\/a\u003e\n        \u003ca class=\"ibgrow-btn\" href=\"\/en\/pages\/servicio-tecnico\"\u003eAsesoramiento e instalación técnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57238907421020,"sku":"LG009","price":504.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/logico2-grow-set.webp?v=1775040658","url":"https:\/\/installbeer.com\/en\/products\/co2-enrichment-controller-logico2-grow-greenhouse-cultivation","provider":"Install Beer","version":"1.0","type":"link"}