{"product_id":"conjunto-basico-detector-co2-logico2-mk90-central-alarma","title":"Basic set of LogiCO2 Mk90 CO2 sensors with central unit and alarm","description":"\u003csection class=\"iblg90-product iblg90-base-set\" data-brand=\"LogiCO2\" data-model=\"Mk90 Detector Base Set\"\u003e\n  \u003cstyle\u003e\n    .iblg90-product{\n      --iblg90-max: 1120px;\n      --iblg90-text: #1f2328;\n      --iblg90-muted: #5b6573;\n      --iblg90-line: #e6e8eb;\n      --iblg90-soft: #f7f8fa;\n      --iblg90-soft2: #f2f4f6;\n      --iblg90-accent: #111111;\n      --iblg90-radius: 18px;\n      --iblg90-shadow: 0 12px 30px rgba(0,0,0,.05);\n      --iblg90-content-size: 16px;\n      --iblg90-content-lh: 1.68;\n      --iblg90-h2-size: 28px;\n      --iblg90-h3-size: 20px;\n      color: var(--iblg90-text);\n      font-size: var(--iblg90-content-size);\n      line-height: var(--iblg90-content-lh);\n    }\n    .iblg90-product *{box-sizing:border-box}\n    .iblg90-wrap{\n      max-width: var(--iblg90-max);\n      margin: 0 auto;\n      padding: 4px 0 36px;\n    }\n    .iblg90-hero,\n    .iblg90-block,\n    .iblg90-specs,\n    .iblg90-faq,\n    .iblg90-downloads{\n      background: #fff;\n      border: 1px solid var(--iblg90-line);\n      border-radius: var(--iblg90-radius);\n      padding: 24px;\n      margin: 0 0 18px;\n      box-shadow: var(--iblg90-shadow);\n    }\n    .iblg90-kicker{\n      display:inline-flex;\n      align-items:center;\n      gap:8px;\n      padding:7px 12px;\n      border:1px solid var(--iblg90-line);\n      border-radius:999px;\n      background:var(--iblg90-soft);\n      color:var(--iblg90-muted);\n      font-size:13px;\n      line-height:1.2;\n      font-weight:700;\n      letter-spacing:.02em;\n      text-transform:uppercase;\n      margin:0 0 14px;\n    }\n    .iblg90-product h2{\n      font-size: var(--iblg90-h2-size);\n      line-height: 1.2;\n      letter-spacing: -.02em;\n      margin: 0 0 14px;\n      color: var(--iblg90-accent);\n    }\n    .iblg90-product h3{\n      font-size: var(--iblg90-h3-size);\n      line-height: 1.28;\n      margin: 0 0 10px;\n      color: var(--iblg90-accent);\n    }\n    .iblg90-product p{\n      margin: 0 0 14px;\n      font-size: var(--iblg90-content-size);\n      line-height: var(--iblg90-content-lh);\n    }\n    .iblg90-product p:last-child{margin-bottom:0}\n    .iblg90-snippet{\n      margin: 0;\n      padding: 16px 18px;\n      border-radius: 14px;\n      background: var(--iblg90-soft);\n      border: 1px solid var(--iblg90-line);\n    }\n    .iblg90-grid-2{\n      display:grid;\n      grid-template-columns: repeat(2,minmax(0,1fr));\n      gap:16px;\n    }\n    .iblg90-cards{\n      display:grid;\n      grid-template-columns: repeat(3,minmax(0,1fr));\n      gap:14px;\n      margin-top:16px;\n    }\n    .iblg90-card{\n      padding:16px;\n      border:1px solid var(--iblg90-line);\n      border-radius:16px;\n      background:var(--iblg90-soft);\n    }\n    .iblg90-card strong{\n      display:block;\n      margin-bottom:6px;\n      color:var(--iblg90-accent);\n    }\n    .iblg90-note{\n      margin-top:16px;\n      padding:14px 16px;\n      border-left:4px solid var(--iblg90-accent);\n      background:var(--iblg90-soft2);\n      border-radius:12px;\n    }\n    .iblg90-list-grid{\n      display:grid;\n      grid-template-columns: repeat(2,minmax(0,1fr));\n      gap:14px;\n      margin:0;\n      padding:0;\n      list-style:none;\n    }\n    .iblg90-list-grid li{\n      padding:16px;\n      border:1px solid var(--iblg90-line);\n      border-radius:16px;\n      background:#fff;\n    }\n    .iblg90-list-grid li strong{\n      display:block;\n      margin-bottom:6px;\n    }\n    .iblg90-bullets{\n      margin:0;\n      padding-left:18px;\n    }\n    .iblg90-bullets li{margin:0 0 10px}\n    .iblg90-table-wrap{\n      width:100%;\n      overflow-x:auto;\n      -webkit-overflow-scrolling:touch;\n    }\n    .iblg90-table{\n      width:100%;\n      min-width:760px;\n      border-collapse:collapse;\n      border:1px solid var(--iblg90-line);\n      border-radius:16px;\n      overflow:hidden;\n      background:#fff;\n    }\n    .iblg90-table caption{\n      caption-side:top;\n      text-align:left;\n      padding:0 0 12px;\n      font-weight:700;\n      color:var(--iblg90-accent);\n    }\n    .iblg90-table thead th{\n      background:var(--iblg90-soft2);\n      color:var(--iblg90-accent);\n      font-weight:700;\n      text-align:left;\n      padding:14px 16px;\n      border-bottom:1px solid var(--iblg90-line);\n      font-size:15px;\n    }\n    .iblg90-table tbody th,\n    .iblg90-table tbody td{\n      padding:14px 16px;\n      border-bottom:1px solid var(--iblg90-line);\n      vertical-align:top;\n      text-align:left;\n      font-size:15px;\n      line-height:1.55;\n    }\n    .iblg90-table tbody th{\n      width:32%;\n      background:#fcfcfd;\n      font-weight:700;\n      color:var(--iblg90-accent);\n    }\n    .iblg90-table tbody tr:last-child th,\n    .iblg90-table tbody tr:last-child td{\n      border-bottom:none;\n    }\n    .iblg90-download-grid{\n      display:grid;\n      grid-template-columns: repeat(2,minmax(0,1fr));\n      gap:12px;\n    }\n    .iblg90-btn{\n      display:flex;\n      align-items:center;\n      justify-content:center;\n      gap:8px;\n      min-height:48px;\n      padding:12px 16px;\n      border-radius:12px;\n      border:1px solid var(--iblg90-accent);\n      text-decoration:none;\n      color:var(--iblg90-accent);\n      font-weight:700;\n      background:#fff;\n      transition:transform .15s ease, box-shadow .15s ease;\n      text-align:center;\n    }\n    .iblg90-btn:hover{\n      transform:translateY(-1px);\n      box-shadow:var(--iblg90-shadow);\n    }\n    .iblg90-faq details{\n      border:1px solid var(--iblg90-line);\n      border-radius:14px;\n      padding:14px 16px;\n      background:#fff;\n      margin-bottom:12px;\n    }\n    .iblg90-faq details:last-child{margin-bottom:0}\n    .iblg90-faq summary{\n      cursor:pointer;\n      font-weight:700;\n      color:var(--iblg90-accent);\n    }\n    .iblg90-faq details p{\n      margin:12px 0 0;\n    }\n    @media (max-width: 900px){\n      .iblg90-cards,\n      .iblg90-list-grid,\n      .iblg90-grid-2,\n      .iblg90-download-grid{\n        grid-template-columns:1fr;\n      }\n    }\n    @media (max-width: 740px){\n      .iblg90-product{\n        --iblg90-content-size: 15px;\n        --iblg90-h2-size: 23px;\n        --iblg90-h3-size: 18px;\n      }\n      .iblg90-hero,\n      .iblg90-block,\n      .iblg90-specs,\n      .iblg90-faq,\n      .iblg90-downloads{\n        padding:18px;\n        border-radius:16px;\n      }\n      .iblg90-table{\n        min-width:100%;\n        border:0;\n      }\n      .iblg90-table caption{\n        padding-bottom:10px;\n      }\n      .iblg90-table thead{\n        position:absolute;\n        width:1px;\n        height:1px;\n        padding:0;\n        margin:-1px;\n        overflow:hidden;\n        clip:rect(0,0,0,0);\n        white-space:nowrap;\n        border:0;\n      }\n      .iblg90-table,\n      .iblg90-table tbody,\n      .iblg90-table tr,\n      .iblg90-table th,\n      .iblg90-table td{\n        display:block;\n        width:100%;\n      }\n      .iblg90-table tr{\n        border:1px solid var(--iblg90-line);\n        border-radius:14px;\n        margin-bottom:12px;\n        overflow:hidden;\n      }\n      .iblg90-table tbody th{\n        background:var(--iblg90-soft2);\n        border-bottom:1px solid var(--iblg90-line);\n      }\n      .iblg90-table tbody td{\n        border-bottom:none;\n        padding-top:12px;\n      }\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblg90-wrap\"\u003e\n    \u003cdiv class=\"iblg90-hero\"\u003e\n      \u003cdiv class=\"iblg90-kicker\"\u003eCO2 Safety · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 Mk90 CO2 detector for monitoring leaks in rooms where CO2 is used\u003c\/h2\u003e\n      \u003cp class=\"iblg90-snippet\"\u003e\u003cstrong\u003eThe basic LogiCO2 Mk90 CO2 detector set combines sensor, central unit and sounder\/beacon to detect CO2 leaks in confined spaces and provide visual and audible warnings, with an installation base already prepared.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eQué aporta este producto\u003c\/h2\u003e\n      \u003cp\u003eThis set is designed to detect CO2 concentrations that may be unhealthy or dangerous in monitored areas. It is particularly suitable for technical rooms, CO2 storage or use areas, beverage dispensing installations, wineries, breweries and other confined spaces where a leak must be identified quickly.\u003c\/p\u003e\n      \u003cp\u003eCompared with scattered solutions, this kit already brings together the system’s essential elements: Mk90 sensor, Mk9 central unit, strobe siren\/beacon, power supply, wiring and signage. This simplifies the initial deployment and provides a solid base for a well-executed professional installation.\u003c\/p\u003e\n      \u003cp\u003eIn addition to visual and audible alarms, the central unit displays CO2, temperature, alarms and system faults. The system can operate from a base configuration of 1 sensor and can be expanded up to 12 sensors as the installation grows.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"iblg90-cards\"\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          2099\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG003\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eConfiguración base\u003c\/strong\u003e\n          1 sensor included, system expandable up to 12 sensors\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eSystem power supply\u003c\/strong\u003e\n          12-24 V CC\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eCommunication\u003c\/strong\u003e\n          RS485 Modbus\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eDefault levels\u003c\/strong\u003e\n          Low alarm 1.5%, high alarm 3%, TWA 5000 ppm\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblg90-note\"\u003e\n        \u003cstrong\u003eImportant:\u003c\/strong\u003e the choice of the number of sensors, their location and the number of sounders\/beacons must be reviewed according to the room volume, CO2 distribution points, ventilation, and access points to the monitored area.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"iblg90-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eComplete base system\u003c\/strong\u003e Includes Mk90 sensor, Mk9 central unit, amber sounder\/beacon, power supply, cables, connectors, signage and documentation.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eNDIR infrared detection\u003c\/strong\u003e The sensor uses non-dispersive infrared analysis and a thermistor to measure CO2 and temperature.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eVisual and audible alarm\u003c\/strong\u003e The low alarm activates the strobe light and the high alarm activates the remote sounder.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCentralized reading and monitoring\u003c\/strong\u003e The central unit displays CO2 levels, sensor information, alarms and system faults.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExpandable\u003c\/strong\u003e The system can operate from a 1-sensor configuration and grow up to 12 sensors.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAutomatic self-calibration\u003c\/strong\u003e Performs self-calibration at regular intervals, reducing the need for manual calibration in a normal environment.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSignage included\u003c\/strong\u003e Includes warning signs and mounting accessories for a more complete installation.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTechnical indoor use\u003c\/strong\u003e Solution aimed at indoor spaces where CO2 is used or stored and leak risk must be controlled.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"iblg90-table-wrap\"\u003e\n        \u003ctable class=\"iblg90-table\"\u003e\n          \u003ccaption\u003eConfirmed technical specifications of the basic LogiCO2 Mk90 CO2 detector set\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eMk90 CO2 Detector Base Set \/ Mk90 Detector Base Set\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG003\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e2099\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003eBasic CO2 safety system with remote sensor, central unit and strobe sounder\/beacon\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConfiguración del conjunto\u003c\/th\u003e\n              \u003ctd\u003e1 Mk90 sensor + 1 Mk9 central unit + 1 amber LED sounder\/beacon + 1 A power supply + cabling and signage\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eNumber of sensors supported per system\u003c\/th\u003e\n              \u003ctd\u003e1–12\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSystem power supply\u003c\/th\u003e\n              \u003ctd\u003e12-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMk90 sensor power supply\u003c\/th\u003e\n              \u003ctd\u003e24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMk9 central unit power supply\u003c\/th\u003e\n              \u003ctd\u003e24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCommunication\u003c\/th\u003e\n              \u003ctd\u003eRS485 Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConexiones de cableado\u003c\/th\u003e\n              \u003ctd\u003eRJ45\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor operating principle\u003c\/th\u003e\n              \u003ctd\u003eInfrarrojo no dispersivo (NDIR) y termistor\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCO2 measuring range\u003c\/th\u003e\n              \u003ctd\u003e0-3 % vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eExtended CO2 range\u003c\/th\u003e\n              \u003ctd\u003e3–6.7% vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModo de muestreo\u003c\/th\u003e\n              \u003ctd\u003eDiffusion\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTWA\u003c\/th\u003e\n              \u003ctd\u003eCalculation of an 8-hour time-weighted average with a 2-minute sampling period.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDefault levels\u003c\/th\u003e\n              \u003ctd\u003eAwareness alert 0.5%; low alarm 1.5%; high alarm 3%; TWA 5000 ppm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePantalla del sensor\u003c\/th\u003e\n              \u003ctd\u003eLCD\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit display\u003c\/th\u003e\n              \u003ctd\u003eGráfica 128x64, retroiluminada\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSound level\u003c\/th\u003e\n              \u003ctd\u003eMk90 sensor: 80 dBa (1 m) max · Mk9 central unit: 80 dBa (1 m) max\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCO2 accuracy\u003c\/th\u003e\n              \u003ctd\u003e±200 ppm ±10 % de la lectura\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePrecisión temperatura\u003c\/th\u003e\n              \u003ctd\u003e±1 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n              \u003ctd\u003eCO2: 0.01% vol. · Temperature: 1 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura de funcionamiento del sensor\u003c\/th\u003e\n              \u003ctd\u003e0 a +45 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit ambient temperature\u003c\/th\u003e\n              \u003ctd\u003e0 to +40 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating humidity\u003c\/th\u003e\n              \u003ctd\u003eSensor: 0–95% RH non-condensing · Central unit: 0–90% non-condensing\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTiempo de calentamiento\u003c\/th\u003e\n              \u003ctd\u003e1 min at 22 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor service life\u003c\/th\u003e\n              \u003ctd\u003e\u003e 15 años\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMk90 sensor dimensions\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMk9 central unit dimensions\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtección contra penetración\u003c\/th\u003e\n              \u003ctd\u003eMk90 sensor: IP54 · Mk9 central unit: IP54 according to TÜV \/ IP44 according to UL\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCalibration\u003c\/th\u003e\n              \u003ctd\u003eAutomatic self-calibration several times a year\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCertificaciones y cumplimiento\u003c\/th\u003e\n              \u003ctd\u003eCE, DIN 6653-2 2015-06, TÜV-Rheinland, UL, EN 50081-1 \/ EN 50082-2, SS-EN 61000-6-3 and SS-EN 61000-6-2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUso\u003c\/th\u003e\n              \u003ctd\u003eSolo para uso en interiores\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMaterial \/ finish\u003c\/th\u003e\n              \u003ctd\u003eData not provided. The set includes a sounder\/beacon with amber lens and protective cover.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003eMk9 central unit, Mk90 sensor, amber LED sounder\/beacon with 1 m cable, protective cover with 6 screws, 5 m red cable, 10 m red cable, 5 m blue cable, RJ45 1-1 and 1-2 splitters, 1 A transformer, UL\/CE\/AU\/UK plugs, plug lock, bag with screws and wall plugs, signs, manual and quick guide.\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThis set is intended for installations where CO2 is used, stored or distributed and where there is a risk of accumulation due to leaks. It is suitable for plant rooms, bottle rooms, cold rooms, areas with piped CO2 supply, wineries, breweries, beverage producers, hospitality and other indoor environments with risks in confined spaces.\u003c\/p\u003e\n      \u003cp\u003eThe base is supplied with an Mk90 sensor, but the system can be expanded to up to 12 sensors if the installation has several risk points. If the monitored area has more than one entrance, it may be necessary to add more than one siren\/beacon to ensure the visibility of the warning signals. A junction box for external signaling is also available.\u003c\/p\u003e\n      \u003cp\u003eIt is compatible with LogiCO2’s own architecture based on RS485 Modbus communication and RJ45 cabling. If the room only has mechanical ventilation, the manufacturer states that it must have a sensor installed.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"iblg90-bullets\"\u003e\n        \u003cli\u003eCheck how many actual CO2 risk points there are in the installation. This set includes 1 sensor, but the system supports up to 12.\u003c\/li\u003e\n        \u003cli\u003eThe Mk90 sensor must be installed at a maximum height of 30 cm above the floor and at a maximum distance of 5 m from the CO2 distribution point.\u003c\/li\u003e\n        \u003cli\u003eEach sensor covers a maximum area of 78 m²; if the area is larger or has several risk points, plan for additional sensors.\u003c\/li\u003e\n        \u003cli\u003eLa unidad central debe instalarse fuera de la zona vigilada, en una posición visible y accesible.\u003c\/li\u003e\n        \u003cli\u003eThe horn\/strobe must be installed above the sensor, approximately 2–2.4 m from the floor and visible from the access points to the area.\u003c\/li\u003e\n        \u003cli\u003eIf there are several doors or access points, consider whether you need a second additional sounder\/beacon at the exit or above the door.\u003c\/li\u003e\n        \u003cli\u003eCheck the available power supply, cable routing, mandatory signage and protection of the units against impacts or movement in the room.\u003c\/li\u003e\n        \u003cli\u003eAs this is a safety system, installation and commissioning must be carried out with proper technical judgment and in compliance with the applicable regulations in each country or project.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eThe system performs automatic self-calibration at regular intervals, which reduces the need for manual service calibration in a normal environment. Even so, as this is a safety product, the manufacturer recommends carrying out at least one functional check per year.\u003c\/p\u003e\n      \u003cp\u003eIn practice, it is advisable to periodically check the condition of the wiring, RJ45 connectors, signage, sounder\/beacon, power supply and alarm response. The central unit itself allows the system to be tested from the reset\/test button, and the audible alarm can be temporarily muted during an alarm situation while the incident is being handled.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat exactly does this LogiCO2 Mk90 basic set include?\u003c\/summary\u003e\n        \u003cp\u003eIncludes Mk90 CO2 sensor, Mk9 central unit, amber LED horn\/strobe, 1 A transformer, cables, RJ45 splitters, protective cover, signage, screws, manual and quick guide.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes this kit already allow you to set up a CO2 alarm system?\u003c\/summary\u003e\n        \u003cp\u003eYes. It is a complete base for one detection point with visual and audible alarm. If the installation has more risk areas, the system can be expanded up to 12 sensors.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhere should the Mk90 sensor be placed?\u003c\/summary\u003e\n        \u003cp\u003eIt must be installed no more than 30 cm from the floor and no more than 5 m from the CO2 distribution point. Each sensor covers a maximum area of 78 m².\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhere are the central unit and the sounder\/beacon installed?\u003c\/summary\u003e\n        \u003cp\u003eThe central unit must be mounted outside the monitored area, in a visible and accessible location. The sounder\/beacon must be placed above the sensor, approximately 2–2.4 m from the floor and visible from the entrance.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes it require periodic manual calibration?\u003c\/summary\u003e\n        \u003cp\u003eIn a normal environment, the system performs automatic self‑calibration and removes the need for manual service calibration. Even so, a functional check is recommended at least once a year.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCan an alarm be muted or reset?\u003c\/summary\u003e\n        \u003cp\u003eYes. The internal sounder of the central unit can be briefly muted. Full alarm reset should only be carried out when the CO2 level has dropped below the low alarm threshold.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"iblg90-download-grid\"\u003e\n        \u003ca class=\"iblg90-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/CO2_Mk90_BaseSET_Amber_2099_es_db_LogiCO2.pdf?v=1772145159\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eLogiCO2 Mk90 Base Set datasheet\u003c\/a\u003e\n        \u003ca class=\"iblg90-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMk9 \/ Mk90 installation manual\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57237640347996,"sku":"LG003","price":594.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/2099-logico2-mk90-alarm-glow.webp?v=1775034323","url":"https:\/\/installbeer.com\/en\/products\/basic-set-co2-detector-logico2-mk90-central-alarm","provider":"Install Beer","version":"1.0","type":"link"}