{"product_id":"kit-adicional-power-barrier-logico2-sistema-seguridad-co2","title":"Additional LogiCO2 Power Barrier Kit for CO2 safety system","description":"\u003csection class=\"ibpb-product ibpb-0482\" data-brand=\"LogiCO2\" data-model=\"Power Barrier Add-on KIT\"\u003e\n  \u003cstyle\u003e\n    .ibpb-product{\n      --ibpb-max:1120px;\n      --ibpb-text:#1f2328;\n      --ibpb-muted:#5b6573;\n      --ibpb-line:#e6e8eb;\n      --ibpb-soft:#f7f8fa;\n      --ibpb-soft2:#f2f4f6;\n      --ibpb-accent:#111111;\n      --ibpb-radius:18px;\n      --ibpb-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibpb-content-size:16px;\n      --ibpb-content-lh:1.68;\n      --ibpb-h2-size:28px;\n      --ibpb-h3-size:20px;\n      color:var(--ibpb-text);\n      font-size:var(--ibpb-content-size);\n      line-height:var(--ibpb-content-lh);\n    }\n    .ibpb-product *{box-sizing:border-box}\n    .ibpb-wrap{max-width:var(--ibpb-max);margin:0 auto;padding:4px 0 36px}\n    .ibpb-hero,.ibpb-block,.ibpb-specs,.ibpb-faq,.ibpb-downloads,.ibpb-related{\n      background:#fff;border:1px solid var(--ibpb-line);border-radius:var(--ibpb-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibpb-shadow)\n    }\n    .ibpb-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibpb-line);\n      border-radius:999px;background:var(--ibpb-soft);color:var(--ibpb-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibpb-product h2{\n      font-size:var(--ibpb-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibpb-accent)\n    }\n    .ibpb-product h3{\n      font-size:var(--ibpb-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibpb-accent)\n    }\n    .ibpb-product p{\n      margin:0 0 14px;\n      font-size:var(--ibpb-content-size);\n      line-height:var(--ibpb-content-lh)\n    }\n    .ibpb-product p:last-child{margin-bottom:0}\n    .ibpb-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibpb-soft);border:1px solid var(--ibpb-line)\n    }\n    .ibpb-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibpb-card{\n      padding:16px;border:1px solid var(--ibpb-line);border-radius:16px;background:var(--ibpb-soft)\n    }\n    .ibpb-card strong{display:block;margin-bottom:6px;color:var(--ibpb-accent)}\n    .ibpb-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibpb-accent);\n      background:var(--ibpb-soft2);border-radius:12px\n    }\n    .ibpb-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibpb-list-grid li{\n      padding:16px;border:1px solid var(--ibpb-line);border-radius:16px;background:#fff\n    }\n    .ibpb-list-grid li strong{display:block;margin-bottom:6px}\n    .ibpb-bullets{margin:0;padding-left:18px}\n    .ibpb-bullets li{margin:0 0 10px}\n    .ibpb-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibpb-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibpb-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibpb-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibpb-accent)\n    }\n    .ibpb-table thead th{\n      background:var(--ibpb-soft2);color:var(--ibpb-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibpb-line);font-size:15px\n    }\n    .ibpb-table tbody th,.ibpb-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibpb-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibpb-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibpb-accent)}\n    .ibpb-table tbody tr:last-child th,.ibpb-table tbody tr:last-child td{border-bottom:none}\n    .ibpb-download-grid,.ibpb-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibpb-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibpb-accent);text-decoration:none;color:var(--ibpb-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibpb-btn:hover{transform:translateY(-1px);box-shadow:var(--ibpb-shadow)}\n    .ibpb-faq details{\n      border:1px solid var(--ibpb-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibpb-faq details:last-child{margin-bottom:0}\n    .ibpb-faq summary{cursor:pointer;font-weight:700;color:var(--ibpb-accent)}\n    .ibpb-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibpb-cards,.ibpb-list-grid,.ibpb-download-grid,.ibpb-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibpb-product{\n        --ibpb-content-size:15px;\n        --ibpb-h2-size:23px;\n        --ibpb-h3-size:18px;\n      }\n      .ibpb-hero,.ibpb-block,.ibpb-specs,.ibpb-faq,.ibpb-downloads,.ibpb-related{\n        padding:18px;border-radius:16px\n      }\n      .ibpb-table{min-width:100%;border:0}\n      .ibpb-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibpb-table,.ibpb-table tbody,.ibpb-table tr,.ibpb-table th,.ibpb-table td{\n        display:block;width:100%\n      }\n      .ibpb-table tr{\n        border:1px solid var(--ibpb-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibpb-table tbody th{\n        background:var(--ibpb-soft2);border-bottom:1px solid var(--ibpb-line)\n      }\n      .ibpb-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibpb-wrap\"\u003e\n    \u003cdiv class=\"ibpb-hero\"\u003e\n      \u003cdiv class=\"ibpb-kicker\"\u003eTechnical accessory · LogiCO2 Safety System\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 Power Barrier to expand power without losing system communication\u003c\/h2\u003e\n      \u003cp class=\"ibpb-snippet\"\u003e\u003cstrong\u003eThe LogiCO2 Power Barrier allows multiple power supplies to be connected in the same CO2 safety system, separating power loops so as not to exceed limits in cables and connectors, while the sensors continue to communicate with the central unit.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eWhat this product offers\u003c\/h2\u003e\n      \u003cp\u003eThis module solves a typical problem in large LogiCO2 systems or those with many connected devices: the total current consumption can approach the safe limit of a single power supply or a single power loop. In that scenario, the Power Barrier helps distribute the load without breaking the system’s communication architecture.\u003c\/p\u003e\n      \u003cp\u003eIts real function is not to detect gas or trigger alarms by itself, but to act as a power distribution accessory within the LogiCO2 safety system. It allows you to work with multiple power supplies and keep different sections of the system electrically separated.\u003c\/p\u003e\n      \u003cp\u003eIn installations with multiple sensors, sounders, remote boxes, or accessories, this type of module helps maintain stability during an alarm, prevent voltage drops, and make future expansions cleaner from a technical standpoint.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"ibpb-cards\"\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eManufacturer’s part number\u003c\/strong\u003e\n          0482\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG028\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eMain function\u003c\/strong\u003e\n          Connect multiple power supplies in the same system\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eMaximum number of power supplies\u003c\/strong\u003e\n          Up to 8\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eModule power supply\u003c\/strong\u003e\n          24 V DC from the alarm system\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibpb-card\"\u003e\n          \u003cstrong\u003eSelf-consumption\u003c\/strong\u003e\n          2 x 17 mA\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"ibpb-note\"\u003e\n        \u003cstrong\u003eEngineering technical note:\u003c\/strong\u003e In Install Beer it is always advisable to calculate the system’s total consumption under alarm conditions. As an internal validation criterion, the need for a Power Barrier is usually considered when the load is already approaching the system’s safe margin and especially when the design includes multiple sensors, sounders, or accessories.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"ibpb-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAllows multiple power supplies\u003c\/strong\u003e The manufacturer states that it can work with up to eight power supplies in the same system.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eRespects per-loop limits\u003c\/strong\u003e Each power supply maintains a 1 A output so as not to exceed power limits in cables and connectors.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eKeeps communication with the central unit\u003c\/strong\u003e Even if the loops are separated in terms of power, the sensors continue to communicate with the central unit.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eGalvanic separation of loops\u003c\/strong\u003e The manufacturer’s example installation shows several power supplies connected and galvanically separated using Power Barriers.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eStatus LED indicators\u003c\/strong\u003e It has two green LEDs to verify that both sides are powered.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompact form factor\u003c\/strong\u003e It shares the usual physical format of LogiCO2 modules, useful for neat technical installations.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAccessory for real expansions\u003c\/strong\u003e It makes sense in systems with multiple sensors, sounders, O2, Mk90, remote boxes, or additional safety accessories.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIntegration in LogiCO2 architecture\u003c\/strong\u003e It is designed for the LogiCO2 Safety System, not as a standalone universal module.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"ibpb-table-wrap\"\u003e\n        \u003ctable class=\"ibpb-table\"\u003e\n          \u003ccaption\u003eConfirmed technical specifications of the LogiCO2 Power Barrier Add-on KIT 0482\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eConfirmed data\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003ePower Barrier Add-on KIT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG028\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ manufacturer part number\u003c\/th\u003e\n              \u003ctd\u003e0482\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003ePower accessory for the LogiCO2 Safety System\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFunction\u003c\/th\u003e\n              \u003ctd\u003eAllow multiple power supplies to be connected in the same system while maintaining communication with the central unit\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMaximum number of power supplies\u003c\/th\u003e\n              \u003ctd\u003eUp to 8\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCapacity per power supply according to the manufacturer\u003c\/th\u003e\n              \u003ctd\u003e1 A output per power supply\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModule power supply\u003c\/th\u003e\n              \u003ctd\u003e24 V DC, supplied from the alarm system\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCurrent consumption\u003c\/th\u003e\n              \u003ctd\u003e2 x 17 mA, with supply from two power sources\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eHumidity\u003c\/th\u003e\n              \u003ctd\u003e0–90% non-condensing\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAmbient temperature\u003c\/th\u003e\n              \u003ctd\u003e0 to +40 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n              \u003ctd\u003eIP54 according to TÜV, IP44 according to UL\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIndicators\u003c\/th\u003e\n              \u003ctd\u003eUpper green LED for the left cable and lower green LED for the right cable; both must be on for correct operation\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eApprovals\u003c\/th\u003e\n              \u003ctd\u003eCE; emission tests according to SS-EN 61000-6-3 and immunity according to SS-EN 61000-6-2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eInstallation compatibility as shown by the manufacturer\u003c\/th\u003e\n              \u003ctd\u003eMk9 Central Unit with Mk9 CO2 sensors, CO2 Mk90 and Mk9 O2 sensor in the same system with multiple power supplies\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eReference peak consumption of the module itself\u003c\/th\u003e\n              \u003ctd\u003e17 mA in the manufacturer’s consumption calculation table\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003ePower Barrier Add-on KIT 0482. The supplied documentation does not detail any additional components in the package.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGTIN\/EAN\u003c\/th\u003e\n              \u003ctd\u003eData not provided\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSA\/HS code\u003c\/th\u003e\n              \u003ctd\u003eData not provided\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n              \u003ctd\u003eData not provided\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThe Power Barrier is designed for the LogiCO2 Safety System ecosystem and makes sense in installations with multiple sensors, multiple sounders, or accessories distributed across different power loops.\u003c\/p\u003e\n      \u003cp\u003eThe manufacturer’s example installation shows compatibility within the same system with a Mk9 central unit, Mk9 CO2 sensors, CO2 Mk90 sensors, and a Mk9 O2 sensor, all communicating with the central unit while power is distributed across several galvanically separated supplies.\u003c\/p\u003e\n      \u003cp\u003eIt is especially useful in hospitality projects, wineries, breweries, technical rooms, beverage plants, or light industrial installations where the system has already grown and the combined consumption makes it advisable to split power by loops.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"ibpb-bullets\"\u003e\n        \u003cli\u003eBefore buying, calculate the system’s total power consumption under alarm conditions, not just in normal operation.\u003c\/li\u003e\n        \u003cli\u003eThe manufacturer itself reminds that one power supply has a 1 A output and provides a peak consumption table to assess whether a Power Barrier is needed.\u003c\/li\u003e\n        \u003cli\u003eCheck how many sensors, sounders, RCB boxes, sniffers, safety valves, or other accessories are part of the system.\u003c\/li\u003e\n        \u003cli\u003eAlso check whether the project uses multiple power supplies and how the loops are physically distributed.\u003c\/li\u003e\n        \u003cli\u003eIf the system is already close to the safe current margin or is going to grow, the Power Barrier leaves the installation better prepared to avoid voltage issues.\u003c\/li\u003e\n        \u003cli\u003eBoth green LEDs on the module must be lit to confirm correct power on both sides.\u003c\/li\u003e\n        \u003cli\u003eSince it is a system engineering accessory, it should be integrated into the overall design and not added as an improvised afterthought.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eThe Power Barrier does not require complex operation, but it is advisable to periodically check the power status on both sides of the module, the mechanical mounting, the wiring, and the load distribution after any system expansions.\u003c\/p\u003e\n      \u003cp\u003eIn practice, every time sensors, sounders, or accessories are added to the LogiCO2 system, it is worth recalculating the consumption and checking that the installation remains within suitable margins. That control is especially important in systems that must remain stable during a real alarm.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat exactly does a LogiCO2 Power Barrier do?\u003c\/summary\u003e\n        \u003cp\u003eIt allows multiple power supplies to be connected in the same LogiCO2 system, separating power loops without losing communication between sensors and the central unit.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIs it used to detect CO2 or trigger alarms?\u003c\/summary\u003e\n        \u003cp\u003eNo. It is a power and distribution accessory. It does not replace sensors, the central unit, or sounders.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhen is it usually needed?\u003c\/summary\u003e\n        \u003cp\u003eIt usually makes sense in larger or heavily loaded systems with multiple sensors, sounders, or accessories, when the consumption calculation suggests splitting the power supply into several loops.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eHow many power supplies can it work with?\u003c\/summary\u003e\n        \u003cp\u003eThe manufacturer states that it allows up to eight power supplies to be connected in the same system.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhich devices is it compatible with?\u003c\/summary\u003e\n        \u003cp\u003eIt is designed for the LogiCO2 Safety System. The documentation shows examples with the Mk9 Central Unit, Mk9 CO2 sensors, CO2 Mk90 sensors, and the Mk9 O2 sensor.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eHow do I know if the module is correctly powered?\u003c\/summary\u003e\n        \u003cp\u003eThe unit has two green LEDs. The upper one indicates power on the left cable and the lower one on the right. Both must be lit for correct operation.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"ibpb-download-grid\"\u003e\n        \u003ca class=\"ibpb-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/Power_Barrier_AddonKIT_0482_en_db_LogiCO2_r4_0.pdf?v=1775122685\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ePower Barrier 0482 datasheet\u003c\/a\u003e\n        \u003ca class=\"ibpb-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/Logico2_stromforbrukning.pdf?v=1775122684\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eLogiCO2 consumption table\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibpb-related\"\u003e\n      \u003ch2\u003eYou may also be interested in\u003c\/h2\u003e\n      \u003cdiv class=\"ibpb-related-grid\"\u003e\n        \u003ca class=\"ibpb-btn\" href=\"\/en\/collections\/logico2\"\u003eLogiCO2 products\u003c\/a\u003e\n        \u003ca class=\"ibpb-btn\" href=\"\/en\/pages\/servicio-tecnico\"\u003eTechnical advice and installation\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57249172848988,"sku":"LG028","price":226.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/powerbarrier-cab-logico2_4fa53e5e-01c2-4255-928b-683afa722d7d.webp?v=1775123735","url":"https:\/\/installbeer.com\/en\/products\/additional-kit-power-barrier-logico2-co2-safety-system","provider":"Install Beer","version":"1.0","type":"link"}