{"product_id":"conjunto-sensores-co2-camaras-frigorificas-logico2-mk90","title":"LogiCO2 Mk90 CO2 sensor set for cold rooms","description":"\u003csection class=\"iblgcr-product iblgcr-3349\" data-brand=\"LogiCO2\" data-model=\"CO2 Cold room Mk90 Detector Base SET\"\u003e\n  \u003cstyle\u003e\n    .iblgcr-product{\n      --ib-max:1120px;\n      --ib-text:#1f2328;\n      --ib-muted:#5b6573;\n      --ib-line:#e6e8eb;\n      --ib-soft:#f7f8fa;\n      --ib-soft2:#f2f4f6;\n      --ib-accent:#111111;\n      --ib-radius:18px;\n      --ib-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ib-content-size:16px;\n      --ib-content-lh:1.68;\n      --ib-h2-size:28px;\n      --ib-h3-size:20px;\n      color:var(--ib-text);\n      font-size:var(--ib-content-size);\n      line-height:var(--ib-content-lh);\n    }\n    .iblgcr-product *{box-sizing:border-box}\n    .iblgcr-wrap{max-width:var(--ib-max);margin:0 auto;padding:4px 0 36px}\n    .iblgcr-hero,.iblgcr-block,.iblgcr-specs,.iblgcr-faq,.iblgcr-downloads,.iblgcr-related{\n      background:#fff;border:1px solid var(--ib-line);border-radius:var(--ib-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ib-shadow)\n    }\n    .iblgcr-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ib-line);\n      border-radius:999px;background:var(--ib-soft);color:var(--ib-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblgcr-product h2{\n      font-size:var(--ib-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ib-accent)\n    }\n    .iblgcr-product h3{\n      font-size:var(--ib-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ib-accent)\n    }\n    .iblgcr-product p{margin:0 0 14px;font-size:var(--ib-content-size);line-height:var(--ib-content-lh)}\n    .iblgcr-product p:last-child{margin-bottom:0}\n    .iblgcr-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ib-soft);border:1px solid var(--ib-line)\n    }\n    .iblgcr-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblgcr-card{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:var(--ib-soft)\n    }\n    .iblgcr-card strong{display:block;margin-bottom:6px;color:var(--ib-accent)}\n    .iblgcr-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ib-accent);\n      background:var(--ib-soft2);border-radius:12px\n    }\n    .iblgcr-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblgcr-list-grid li{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:#fff\n    }\n    .iblgcr-list-grid li strong{display:block;margin-bottom:6px}\n    .iblgcr-bullets{margin:0;padding-left:18px}\n    .iblgcr-bullets li{margin:0 0 10px}\n    .iblgcr-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblgcr-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ib-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblgcr-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ib-accent)\n    }\n    .iblgcr-table thead th{\n      background:var(--ib-soft2);color:var(--ib-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);font-size:15px\n    }\n    .iblgcr-table tbody th,.iblgcr-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblgcr-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ib-accent)}\n    .iblgcr-table tbody tr:last-child th,.iblgcr-table tbody tr:last-child td{border-bottom:none}\n    .iblgcr-download-grid,.iblgcr-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblgcr-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ib-accent);text-decoration:none;color:var(--ib-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblgcr-btn:hover{transform:translateY(-1px);box-shadow:var(--ib-shadow)}\n    .iblgcr-faq details{\n      border:1px solid var(--ib-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblgcr-faq details:last-child{margin-bottom:0}\n    .iblgcr-faq summary{cursor:pointer;font-weight:700;color:var(--ib-accent)}\n    .iblgcr-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblgcr-cards,.iblgcr-list-grid,.iblgcr-download-grid,.iblgcr-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblgcr-product{\n        --ib-content-size:15px;\n        --ib-h2-size:23px;\n        --ib-h3-size:18px;\n      }\n      .iblgcr-hero,.iblgcr-block,.iblgcr-specs,.iblgcr-faq,.iblgcr-downloads,.iblgcr-related{\n        padding:18px;border-radius:16px\n      }\n      .iblgcr-table{min-width:100%;border:0}\n      .iblgcr-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblgcr-table,.iblgcr-table tbody,.iblgcr-table tr,.iblgcr-table th,.iblgcr-table td{\n        display:block;width:100%\n      }\n      .iblgcr-table tr{\n        border:1px solid var(--ib-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblgcr-table tbody th{\n        background:var(--ib-soft2);border-bottom:1px solid var(--ib-line)\n      }\n      .iblgcr-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblgcr-wrap\"\u003e\n    \u003cdiv class=\"iblgcr-hero\"\u003e\n      \u003cdiv class=\"iblgcr-kicker\"\u003eCO2 safety · Cold rooms\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 CO2 sensor for cold rooms with reliable detection in low temperatures\u003c\/h2\u003e\n      \u003cp class=\"iblgcr-snippet\"\u003e\u003cstrong\u003eThe LogiCO2 3349 set is a CO2 detection system for cold rooms and freezers with a Cold Room sensor, Mk9 central unit and sounder\/beacon to monitor leaks in cold environments where a conventional detector may lose accuracy.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eQué aporta este producto\u003c\/h2\u003e\n      \u003cp\u003eThis unit is designed for cold rooms and freezing applications where CO2 may accumulate due to a leak and a standard detector does not provide a sufficiently reliable response at low temperature.\u003c\/p\u003e\n      \u003cp\u003eThe real advantage of this set is that it already includes the core of the system: low-temperature-specific sensor, Mk9 central unit, sounder\/beacon, power supply, connectors, signage, and protective cover. This reduces configuration errors and simplifies a technically sound installation.\u003c\/p\u003e\n      \u003cp\u003eIn addition, the manufacturer states that the Cold Room solution is specially adapted to refrigeration and freezing, and that the sensor differs from the standard Mk90 in its temperature range and in an alarm level configurable via DIP switch 1.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-cards\"\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          3349\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG007\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eMain application\u003c\/strong\u003e\n          Cold rooms and freezers\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eSensor\u003c\/strong\u003e\n          Cold Room CO2 Sensor\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eCentral unit included\u003c\/strong\u003e\n          Mk9 central unit\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eSensor operating temperature\u003c\/strong\u003e\n          From -40 °C to 25 °C\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblgcr-note\"\u003e\n        \u003cstrong\u003eImportant:\u003c\/strong\u003e this product is aimed at cold environments. If your installation has several risk points or several cold rooms, the manufacturer’s own documentation allows for expansion with additional kits and up to twelve sensors on a single central unit.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"iblgcr-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDesigned for real cold\u003c\/strong\u003e The manufacturer has tailored it specifically for cold rooms and freezers, where a conventional detector may drift more.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eComplete base set\u003c\/strong\u003e Includes Cold Room sensor, Mk9 central unit, sounder\/beacon, power supply, connectors, cabling, manual and signage.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAccurate CO2 detection\u003c\/strong\u003e It is designed for safety in environments where a leak may go unnoticed if the sensor is not prepared for low temperature.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eProfessional architecture\u003c\/strong\u003e Uses RS485 Modbus communication, common in technical supervision systems.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExpandable\u003c\/strong\u003e Up to twelve sensors can be connected to one central unit and additional kits integrate in plug-and-play mode.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eVisual and audible alarm\u003c\/strong\u003e The strobe sounder\/beacon helps to warn both inside and outside the monitored area.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAltitude compensation\u003c\/strong\u003e The sensor can be adjusted to compensate for the installation altitude.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAutomatic calibration\u003c\/strong\u003e Performs self-calibration several times a year.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-table-wrap\"\u003e\n        \u003ctable class=\"iblgcr-table\"\u003e\n          \u003ccaption\u003eConfirmed technical specifications of the LogiCO2 Cold Room 3349 set\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eCO2 Cold Room Mk90 Detector Base SET \/ CO2 sensor set for cold rooms\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG007\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e3349\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003eBase CO2 detection system for cold rooms and freezers\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n              \u003ctd\u003eCold room and freezer applications\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMain components of the set\u003c\/th\u003e\n              \u003ctd\u003eCO2 Cold Room Sensor + Central Unit Mk9 + Amber LED glass Horn\/Strobe + Power Supply 1A + Protection Cover\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor reference\u003c\/th\u003e\n              \u003ctd\u003e1153\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit reference\u003c\/th\u003e\n              \u003ctd\u003e1148\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eHorn\/strobe reference\u003c\/th\u003e\n              \u003ctd\u003e0440\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePower supply reference\u003c\/th\u003e\n              \u003ctd\u003e0021\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtective cover reference\u003c\/th\u003e\n              \u003ctd\u003e0185\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFuente de alimentación del sistema\u003c\/th\u003e\n              \u003ctd\u003e12-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCommunication\u003c\/th\u003e\n              \u003ctd\u003eRS485 Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAutomatic calibration\u003c\/th\u003e\n              \u003ctd\u003eSeveral times a year\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor ingress protection\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura de funcionamiento del sensor\u003c\/th\u003e\n              \u003ctd\u003eFrom -40 °C to 25 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePreset alarm levels\u003c\/th\u003e\n              \u003ctd\u003e5000 ppm awareness indication, 5000 ppm TWA\/8 h alarm, 1.5% low alarm, 3.0% high alarm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAjuste adicional\u003c\/th\u003e\n              \u003ctd\u003eCompensación de altitud\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza tensión nominal\u003c\/th\u003e\n              \u003ctd\u003e18–24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSounder\/beacon power consumption\u003c\/th\u003e\n              \u003ctd\u003e80 mA peak with 24 V DC supply\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSounder\/beacon sound level\u003c\/th\u003e\n              \u003ctd\u003e110 dB \/ 1 m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza intensidad del flash\u003c\/th\u003e\n              \u003ctd\u003e115 CD\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza frecuencia del flash\u003c\/th\u003e\n              \u003ctd\u003e65\/min\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza temperatura ambiente\u003c\/th\u003e\n              \u003ctd\u003eFrom -5 °C to +50 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSounder\/beacon dimensions\u003c\/th\u003e\n              \u003ctd\u003e134 x 115 x 61 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza protección\u003c\/th\u003e\n              \u003ctd\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit communication\u003c\/th\u003e\n              \u003ctd\u003eRS485, Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit display\u003c\/th\u003e\n              \u003ctd\u003e128x64 graphic display, backlit\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit audible signal\u003c\/th\u003e\n              \u003ctd\u003e80 dBa (1 m) max.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit ambient temperature\u003c\/th\u003e\n              \u003ctd\u003eFrom 0 to +40 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit humidity\u003c\/th\u003e\n              \u003ctd\u003e0-90 % sin condensación\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit dimensions\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit protection\u003c\/th\u003e\n              \u003ctd\u003eIP54 according to TÜV, IP44 according to UL\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eExpansion capacity\u003c\/th\u003e\n              \u003ctd\u003eUp to 12 sensors connected to a central unit\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003eCO2 Mk90 incl. one 10 m blue cable and one 5 m red cable, strobe sounder\/beacon with amber LED lens with blue indicator incl. 1 m cable and sign, RJ45 1-1 splitter, 1 A transformer, plug lock, bag with 3 gland seals, 6 strips, 24 screws and wall plugs, signs, Mk90 manual, Mk90 quick guide and protective cover.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCertificaciones y cumplimiento\u003c\/th\u003e\n              \u003ctd\u003eCE, UL, DIN6653-2 2015-06, EN55022:2006\/A1:2007, EN55024\/A2:2003, EN61000-3-2:2006, EN61000-3-3\/A2:2006, AS\/NZS CISPR 22:2006, IEC\/EN IT55022\/55024, LNE Règle de certification NF 128.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGTIN\/EAN\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThis set is designed for cold rooms, freezers, cold storage areas, gas rooms connected to cold rooms and other cold indoor spaces where CO2 is used and there is a risk of accumulation due to leakage.\u003c\/p\u003e\n      \u003cp\u003eSuitable for hospitality, food retail, wineries, breweries, beverage producers, the food industry and any facility where CO2 is used in cold rooms or low-temperature enclosures.\u003c\/p\u003e\n      \u003cp\u003eThe manufacturer’s own documentation allows expansion with additional kits, relay kits and connection to building management systems, always within the LogiCO2 architecture.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"iblgcr-bullets\"\u003e\n        \u003cli\u003eEl sensor debe instalarse a una altura máxima de 30 cm del suelo y a una distancia máxima de 5 m del punto de distribución de CO2.\u003c\/li\u003e\n        \u003cli\u003eEach sensor covers a maximum area of 78 m²; if the cold room or area is larger, consider additional sensors.\u003c\/li\u003e\n        \u003cli\u003eThe sounder\/beacon must be placed above the sensor, approximately 2–2.4 m from the floor, clearly visible from any entrance.\u003c\/li\u003e\n        \u003cli\u003eThe documentation also recommends installing a second sounder\/beacon outside the monitored area, preferably above the access door or doors.\u003c\/li\u003e\n        \u003cli\u003eThe central unit must be installed outside the monitored area, in a visible and accessible position.\u003c\/li\u003e\n        \u003cli\u003eCheck the available power supply, the RJ45 cable routing and compatibility with the system architecture if you plan future expansions.\u003c\/li\u003e\n        \u003cli\u003eAs this is a safety product, installation and commissioning must be carried out with technical expertise and final functional verification.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eThe sensor performs automatic calibration several times a year. Even so, as this is a CO2 safety system, it is advisable to periodically check cables, connectors, visibility of signage, sounder\/beacon, and correct reading on the central unit.\u003c\/p\u003e\n      \u003cp\u003eThe general system documentation recommends that a qualified professional agent perform a functional check at least once a year. Cleaning should be done with water and a damp cloth, avoiding any unauthorised tampering with the equipment.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIs this product for cold rooms and freezers?\u003c\/summary\u003e\n        \u003cp\u003eYes. Item 3349 is specifically designed for cold room and freezer applications.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes it include an Mk9 central unit?\u003c\/summary\u003e\n        \u003cp\u003eYes. This base set includes a Cold Room sensor, Mk9 central unit, sounder\/beacon, power supply, connectors, manual and signage.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eHow does it differ from a conventional detector?\u003c\/summary\u003e\n        \u003cp\u003eThe manufacturer’s own datasheet explains that conventional detectors are not designed for cold environments and may have a high margin of error. This sensor is adapted to low temperatures.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhere should the sensor be installed?\u003c\/summary\u003e\n        \u003cp\u003eIt must be mounted at a maximum of 30 cm from the floor and at a maximum of 5 m from the CO2 distribution point. Each sensor covers up to 78 m².\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCan the system be expanded?\u003c\/summary\u003e\n        \u003cp\u003eYes. The documentation for item 3349 states that up to 12 sensors can be connected to one central unit and that additional kits are installed in plug-and-play mode.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes it require periodic maintenance?\u003c\/summary\u003e\n        \u003cp\u003eYes. Although the sensor performs automatic calibration, it is advisable to carry out periodic functional checks and have a professional inspection at least once a year.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-download-grid\"\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/CO2_Coldroom_SensorSET_3349_es_db_LogiCO2.pdf?v=1775036243\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eLogiCO2 Datasheet 3349\u003c\/a\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMk9 \/ Mk90 manual\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-related\"\u003e\n      \u003ch2\u003eTambién puede interesarte\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-related-grid\"\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"\/en-in\/collections\/alarmas-detectores-co2-logico2\"\u003eLogiCO2 CO2 alarms and detectors\u003c\/a\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"\/en-in\/pages\/servicio-tecnico\"\u003eAsesoramiento e instalación técnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57238894084444,"sku":"LG007","price":70500.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/coldroom-co2sensor-set-logico2.webp?v=1775036636","url":"https:\/\/installbeer.com\/en-in\/products\/set-co2-sensors-cold-rooms-logico2-mk90","provider":"Install Beer","version":"1.0","type":"link"}