{"product_id":"kit-adicional-de-valvula-de-seguridad-y-smb-logico2-para-sistemas-co2","title":"Additional LogiCO2 safety valve and SMB kit for CO2 systems","description":"\u003csection class=\"ibsmb-product ibsmb-0476\" data-brand=\"LogiCO2\" data-model=\"SMB Safety Valve Add-on KIT\"\u003e\n  \u003cstyle\u003e\n    .ibsmb-product{\n      --ibsmb-max:1120px;\n      --ibsmb-text:#1f2328;\n      --ibsmb-muted:#5b6573;\n      --ibsmb-line:#e6e8eb;\n      --ibsmb-soft:#f7f8fa;\n      --ibsmb-soft2:#f2f4f6;\n      --ibsmb-accent:#111111;\n      --ibsmb-radius:18px;\n      --ibsmb-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibsmb-content-size:16px;\n      --ibsmb-content-lh:1.68;\n      --ibsmb-h2-size:28px;\n      --ibsmb-h3-size:20px;\n      color:var(--ibsmb-text);\n      font-size:var(--ibsmb-content-size);\n      line-height:var(--ibsmb-content-lh);\n    }\n    .ibsmb-product *{box-sizing:border-box}\n    .ibsmb-wrap{max-width:var(--ibsmb-max);margin:0 auto;padding:4px 0 36px}\n    .ibsmb-hero,.ibsmb-block,.ibsmb-specs,.ibsmb-faq,.ibsmb-downloads,.ibsmb-related{\n      background:#fff;border:1px solid var(--ibsmb-line);border-radius:var(--ibsmb-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibsmb-shadow)\n    }\n    .ibsmb-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibsmb-line);\n      border-radius:999px;background:var(--ibsmb-soft);color:var(--ibsmb-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibsmb-product h2{\n      font-size:var(--ibsmb-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibsmb-accent)\n    }\n    .ibsmb-product h3{\n      font-size:var(--ibsmb-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibsmb-accent)\n    }\n    .ibsmb-product p{\n      margin:0 0 14px;\n      font-size:var(--ibsmb-content-size);\n      line-height:var(--ibsmb-content-lh)\n    }\n    .ibsmb-product p:last-child{margin-bottom:0}\n    .ibsmb-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibsmb-soft);border:1px solid var(--ibsmb-line)\n    }\n    .ibsmb-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibsmb-card{\n      padding:16px;border:1px solid var(--ibsmb-line);border-radius:16px;background:var(--ibsmb-soft)\n    }\n    .ibsmb-card strong{display:block;margin-bottom:6px;color:var(--ibsmb-accent)}\n    .ibsmb-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibsmb-accent);\n      background:var(--ibsmb-soft2);border-radius:12px\n    }\n    .ibsmb-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibsmb-list-grid li{\n      padding:16px;border:1px solid var(--ibsmb-line);border-radius:16px;background:#fff\n    }\n    .ibsmb-list-grid li strong{display:block;margin-bottom:6px}\n    .ibsmb-bullets{margin:0;padding-left:18px}\n    .ibsmb-bullets li{margin:0 0 10px}\n    .ibsmb-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibsmb-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibsmb-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibsmb-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibsmb-accent)\n    }\n    .ibsmb-table thead th{\n      background:var(--ibsmb-soft2);color:var(--ibsmb-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibsmb-line);font-size:15px\n    }\n    .ibsmb-table tbody th,.ibsmb-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibsmb-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibsmb-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibsmb-accent)}\n    .ibsmb-table tbody tr:last-child th,.ibsmb-table tbody tr:last-child td{border-bottom:none}\n    .ibsmb-download-grid,.ibsmb-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibsmb-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibsmb-accent);text-decoration:none;color:var(--ibsmb-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibsmb-btn:hover{transform:translateY(-1px);box-shadow:var(--ibsmb-shadow)}\n    .ibsmb-faq details{\n      border:1px solid var(--ibsmb-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibsmb-faq details:last-child{margin-bottom:0}\n    .ibsmb-faq summary{cursor:pointer;font-weight:700;color:var(--ibsmb-accent)}\n    .ibsmb-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibsmb-cards,.ibsmb-list-grid,.ibsmb-download-grid,.ibsmb-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibsmb-product{\n        --ibsmb-content-size:15px;\n        --ibsmb-h2-size:23px;\n        --ibsmb-h3-size:18px;\n      }\n      .ibsmb-hero,.ibsmb-block,.ibsmb-specs,.ibsmb-faq,.ibsmb-downloads,.ibsmb-related{\n        padding:18px;border-radius:16px\n      }\n      .ibsmb-table{min-width:100%;border:0}\n      .ibsmb-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibsmb-table,.ibsmb-table tbody,.ibsmb-table tr,.ibsmb-table th,.ibsmb-table td{\n        display:block;width:100%\n      }\n      .ibsmb-table tr{\n        border:1px solid var(--ibsmb-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibsmb-table tbody th{\n        background:var(--ibsmb-soft2);border-bottom:1px solid var(--ibsmb-line)\n      }\n      .ibsmb-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibsmb-wrap\"\u003e\n    \u003cdiv class=\"ibsmb-hero\"\u003e\n      \u003cdiv class=\"ibsmb-kicker\"\u003eCO2 Safety · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 SMB safety valve to shut off CO2 in case of leak\u003c\/h2\u003e\n      \u003cp class=\"ibsmb-snippet\"\u003e\u003cstrong\u003eThe LogiCO2 SMB and safety valve add‑on kit automatically shuts off CO2 distribution when an Mk9 or Mk90 sensor detects a high concentration, helping to limit the leak from the start of the gas line.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eWhat this product offers\u003c\/h2\u003e\n      \u003cp\u003eThis accessory is designed to add an active safety measure to the LogiCO2 system: not only detecting a leak, but also shutting off the gas supply when an alarm occurs.\u003c\/p\u003e\n      \u003cp\u003eIts technical value lies in the fact that the solenoid valve acts on the CO2 distribution and operates in fail-safe mode. This means that if power is lost, the valve closes.\u003c\/p\u003e\n      \u003cp\u003eIn a real installation, this helps reduce the risk of continuing to feed a leak from the cylinder or tank into the distribution line.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"ibsmb-cards\"\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003eManufacturer’s part number\u003c\/strong\u003e\n          0476\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG010\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003eCompatibility\u003c\/strong\u003e\n          LogiCO2 Mk9 and Mk90 CO2 systems\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003eWorking pressure\u003c\/strong\u003e\n          0.15 to 30 bar\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003eThreaded connection\u003c\/strong\u003e\n          1\/4\"–18 NPT\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibsmb-card\"\u003e\n          \u003cstrong\u003eSafety mode\u003c\/strong\u003e\n          Fail‑safe, power‑off closing\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"ibsmb-note\"\u003e\n        \u003cstrong\u003eImportant note:\u003c\/strong\u003e this product does not replace the detector or the central unit. It is an additional accessory that acts on the gas line when the LogiCO2 system detects a leak.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"ibsmb-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAutomatic CO2 shut-off\u003c\/strong\u003e Shuts off the gas supply when the sensor detects a high CO2 concentration.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFail‑safe valve\u003c\/strong\u003e It closes in the event of power loss, adding a layer of passive safety.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompatible with Mk9 and Mk90\u003c\/strong\u003e Designed as an accessory for LogiCO2 Mk9 and Mk90 CO2 safety systems.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBlue RJ45 signal output\u003c\/strong\u003e The electronic box connects to the sensor’s blue alarm signaling side.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFactory setting on high alarm\u003c\/strong\u003e Supplied configured to close on high alarm, with the option to change it to low\/pre-alarm via jumper.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eVisual status indicator\u003c\/strong\u003e Includes a red indicator showing that the valve is open.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompact format\u003c\/strong\u003e Electronic enclosure 78 x 78 x 37 mm, easy to integrate into technical rooms.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eInstallation near the cylinder\u003c\/strong\u003e The manufacturer recommends installing it as early as possible in the distribution chain, near the CO2 tank.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"ibsmb-table-wrap\"\u003e\n        \u003ctable class=\"ibsmb-table\"\u003e\n          \u003ccaption\u003eConfirmed technical specifications of the additional LogiCO2 safety valve and SMB KIT\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eConfirmed data\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eSMB Safety Valve Add-on KIT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG010\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ manufacturer part number\u003c\/th\u003e\n              \u003ctd\u003e0476\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003eFail‑safe box with safety valve for CO2 safety system\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCompatibility\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2 Mk9 and Mk90 CO2 safety system\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFunction\u003c\/th\u003e\n              \u003ctd\u003eShut off CO2 gas distribution in case of a leak\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eValve type\u003c\/th\u003e\n              \u003ctd\u003eMagnetic safety shutoff valve\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFail‑safe mode\u003c\/th\u003e\n              \u003ctd\u003eYes, the valve closes in the event of power loss\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFuente de alimentación\u003c\/th\u003e\n              \u003ctd\u003eThrough the CO2 sensor\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eRelés\u003c\/th\u003e\n              \u003ctd\u003e1A \/ 24 V CA\/CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n              \u003ctd\u003ePC\/ABS\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating pressure\u003c\/th\u003e\n              \u003ctd\u003e0.15 to 30 bar \/ 2.2 to 435 psi\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBurst pressure\u003c\/th\u003e\n              \u003ctd\u003e\u003e150 bar \/ 2175 psi\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eThreaded connection\u003c\/th\u003e\n              \u003ctd\u003e1\/4\"–18 NPT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n              \u003ctd\u003e78 x 78 x 37 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n              \u003ctd\u003eIP55\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWired\u003c\/th\u003e\n              \u003ctd\u003e1 m Cat. 5 cable from the electronics box with blue RJ45 connector\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFactory setting\u003c\/th\u003e\n              \u003ctd\u003eHigh‑alarm shutoff\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConfigurable setting\u003c\/th\u003e\n              \u003ctd\u003eIt can be changed to close on low alarm\/pre-alarm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eStatus indicator\u003c\/th\u003e\n              \u003ctd\u003eRed indicator; lit means valve open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003eSMB + safety shut-off valve + 1 m cable; the datasheet also states delivery with 1-4 RJ45 splitter and the official page specifies valve without filter\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThis kit is intended for CO2 installations where a LogiCO2 Mk9 or Mk90 system is already in place and you want to add automatic gas shutoff in the event of a leak.\u003c\/p\u003e\n      \u003cp\u003eIt is suitable for hospitality, wineries, breweries, cold rooms, technical rooms and any installation where the CO2 cylinder or tank feeds a distribution network and it is advisable to interrupt the supply in case of alarm.\u003c\/p\u003e\n      \u003cp\u003eIt also makes sense when the project includes a central unit, sensors, horn\/beacon, and other safety accessories within the LogiCO2 architecture.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"ibsmb-bullets\"\u003e\n        \u003cli\u003eThe solenoid valve must be installed as early as possible in the gas distribution line, close to the CO2 tank or cylinder.\u003c\/li\u003e\n        \u003cli\u003eThe electronic box must be mounted in a mechanically protected location.\u003c\/li\u003e\n        \u003cli\u003eThe connection is made using the blue RJ45 connector on the blue alarm signaling output side of the Mk9 or Mk90 sensor.\u003c\/li\u003e\n        \u003cli\u003eBefore purchasing, confirm the thread of the installation: 1\/4”-18NPT.\u003c\/li\u003e\n        \u003cli\u003eAlso check the actual working pressure of the circuit, which must be within 0.15 to 30 bar.\u003c\/li\u003e\n        \u003cli\u003eIf the installation design is large or has many accessories, it is advisable to review the total system consumption and the power distribution within the LogiCO2 architecture.\u003c\/li\u003e\n        \u003cli\u003eAs safety equipment, installation and commissioning must be carried out with technical criteria and final functional verification.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eThe manufacturer recommends an annual functional check. To test the valve, the indicator must be lit, which shows that the valve is open.\u003c\/p\u003e\n      \u003cp\u003eThe test is carried out by pressing the test button on the SMB junction box: the indicator light must go out and the valve must make a clear clicking sound. After any intervention in the system, it is advisable to repeat this check.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat exactly is the SMB with safety valve used for?\u003c\/summary\u003e\n        \u003cp\u003eIt is used to automatically shut off CO2 distribution when the LogiCO2 system detects a leak or a high concentration.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIs it compatible with any detector?\u003c\/summary\u003e\n        \u003cp\u003eNo. It is designed as an accessory for LogiCO2 CO2 Mk9 and Mk90 systems.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhere should the valve be installed?\u003c\/summary\u003e\n        \u003cp\u003eIt must be installed as close as possible to the CO2 tank or cylinder, at the start of the distribution chain.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat happens if the power supply is cut?\u003c\/summary\u003e\n        \u003cp\u003eThe valve is fail-safe, so it closes in the event of a power loss.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIs it configured for high alarm or low alarm?\u003c\/summary\u003e\n        \u003cp\u003eFrom the factory it is configured to close on high alarm, although it can be adjusted to operate on low alarm or pre‑alarm.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eHow do you check that it is working correctly?\u003c\/summary\u003e\n        \u003cp\u003eThe manufacturer recommends an annual test: with the indicator lit, press the test button on the SMB; the indicator should go out and you should hear a click from the valve.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"ibsmb-download-grid\"\u003e\n        \u003ca class=\"ibsmb-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/SMB_sov_AddonKIT_0476_es.pdf?v=1776182868\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSMB datasheet and safety valve\u003c\/a\u003e\n        \u003ca class=\"ibsmb-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/smb_sv_0476_es_in_hfe1262.pdf?v=1776182868\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSMB and safety valve installation manual\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibsmb-related\"\u003e\n      \u003ch2\u003eYou may also be interested in\u003c\/h2\u003e\n      \u003cdiv class=\"ibsmb-related-grid\"\u003e\n        \u003ca class=\"ibsmb-btn\" href=\"\/en-in\/collections\/logico2-detectores-co2-seguridad-industrial-horeca\"\u003eLogiCO2 products\u003c\/a\u003e\n        \u003ca class=\"ibsmb-btn\" href=\"\/en-in\/pages\/servicio-tecnico\"\u003eTechnical advice and installation\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57365627044188,"sku":"LG010","price":43100.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/0476-smb-safetyvalve-logico2.webp?v=1776183246","url":"https:\/\/installbeer.com\/en-in\/products\/additional-safety-valve-and-smb-logico2-kit-for-co2-systems","provider":"Install Beer","version":"1.0","type":"link"}