{"product_id":"kit-adicional-sensor-co2-logico2-mk90-alarma","title":"Additional LogiCO2 Mk90 CO2 sensor kit with alarm","description":"\u003csection class=\"iblg90-product iblg90-addon\" data-brand=\"LogiCO2\" data-model=\"Mk90 Sensor Add-on KIT\"\u003e\n  \u003cstyle\u003e\n    .iblg90-product{\n      --iblg90-max:1120px;\n      --iblg90-text:#1f2328;\n      --iblg90-muted:#5b6573;\n      --iblg90-line:#e6e8eb;\n      --iblg90-soft:#f7f8fa;\n      --iblg90-soft2:#f2f4f6;\n      --iblg90-accent:#111111;\n      --iblg90-radius:18px;\n      --iblg90-shadow:0 12px 30px rgba(0,0,0,.05);\n      --iblg90-content-size:16px;\n      --iblg90-content-lh:1.68;\n      --iblg90-h2-size:28px;\n      --iblg90-h3-size:20px;\n      color:var(--iblg90-text);\n      font-size:var(--iblg90-content-size);\n      line-height:var(--iblg90-content-lh);\n    }\n    .iblg90-product *{box-sizing:border-box}\n    .iblg90-wrap{max-width:var(--iblg90-max);margin:0 auto;padding:4px 0 36px}\n    .iblg90-hero,.iblg90-block,.iblg90-specs,.iblg90-faq,.iblg90-downloads{\n      background:#fff;border:1px solid var(--iblg90-line);border-radius:var(--iblg90-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--iblg90-shadow)\n    }\n    .iblg90-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--iblg90-line);\n      border-radius:999px;background:var(--iblg90-soft);color:var(--iblg90-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblg90-product h2{\n      font-size:var(--iblg90-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--iblg90-accent)\n    }\n    .iblg90-product h3{\n      font-size:var(--iblg90-h3-size);line-height:1.28;margin:0 0 10px;color:var(--iblg90-accent)\n    }\n    .iblg90-product p{margin:0 0 14px;font-size:var(--iblg90-content-size);line-height:var(--iblg90-content-lh)}\n    .iblg90-product p:last-child{margin-bottom:0}\n    .iblg90-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--iblg90-soft);border:1px solid var(--iblg90-line)\n    }\n    .iblg90-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblg90-card{\n      padding:16px;border:1px solid var(--iblg90-line);border-radius:16px;background:var(--iblg90-soft)\n    }\n    .iblg90-card strong{display:block;margin-bottom:6px;color:var(--iblg90-accent)}\n    .iblg90-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--iblg90-accent);\n      background:var(--iblg90-soft2);border-radius:12px\n    }\n    .iblg90-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblg90-list-grid li{\n      padding:16px;border:1px solid var(--iblg90-line);border-radius:16px;background:#fff\n    }\n    .iblg90-list-grid li strong{display:block;margin-bottom:6px}\n    .iblg90-bullets{margin:0;padding-left:18px}\n    .iblg90-bullets li{margin:0 0 10px}\n    .iblg90-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblg90-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--iblg90-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblg90-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--iblg90-accent)\n    }\n    .iblg90-table thead th{\n      background:var(--iblg90-soft2);color:var(--iblg90-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--iblg90-line);font-size:15px\n    }\n    .iblg90-table tbody th,.iblg90-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--iblg90-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblg90-table tbody th{width:32%;background:#fcfcfd;font-weight:700;color:var(--iblg90-accent)}\n    .iblg90-table tbody tr:last-child th,.iblg90-table tbody tr:last-child td{border-bottom:none}\n    .iblg90-download-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblg90-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--iblg90-accent);text-decoration:none;color:var(--iblg90-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblg90-btn:hover{transform:translateY(-1px);box-shadow:var(--iblg90-shadow)}\n    .iblg90-faq details{\n      border:1px solid var(--iblg90-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblg90-faq details:last-child{margin-bottom:0}\n    .iblg90-faq summary{cursor:pointer;font-weight:700;color:var(--iblg90-accent)}\n    .iblg90-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblg90-cards,.iblg90-list-grid,.iblg90-download-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblg90-product{\n        --iblg90-content-size:15px;\n        --iblg90-h2-size:23px;\n        --iblg90-h3-size:18px;\n      }\n      .iblg90-hero,.iblg90-block,.iblg90-specs,.iblg90-faq,.iblg90-downloads{\n        padding:18px;border-radius:16px\n      }\n      .iblg90-table{min-width:100%;border:0}\n      .iblg90-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblg90-table,.iblg90-table tbody,.iblg90-table tr,.iblg90-table th,.iblg90-table td{\n        display:block;width:100%\n      }\n      .iblg90-table tr{\n        border:1px solid var(--iblg90-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblg90-table tbody th{\n        background:var(--iblg90-soft2);border-bottom:1px solid var(--iblg90-line)\n      }\n      .iblg90-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblg90-wrap\"\u003e\n    \u003cdiv class=\"iblg90-hero\"\u003e\n      \u003cdiv class=\"iblg90-kicker\"\u003eSeguridad CO2 · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eAdditional LogiCO2 Mk90 CO2 sensor kit to expand an existing system\u003c\/h2\u003e\n      \u003cp class=\"iblg90-snippet\"\u003e\u003cstrong\u003eThe additional LogiCO2 Mk90 CO2 sensor kit adds a new detection point with sounder\/beacon to an already installed LogiCO2 system to monitor CO2 leaks in technical rooms, cold rooms or dispensing areas with a risk of accumulation.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eQué aporta este producto\u003c\/h2\u003e\n      \u003cp\u003eThis kit is designed to expand an existing LogiCO2 safety system. It is not a standalone set with a central unit, but an additional sensor with visual and audible alarm to cover another risk area or a new CO2 distribution point.\u003c\/p\u003e\n      \u003cp\u003eIt is especially suitable for installations where CO2 can accumulate due to leakage: technical rooms, enclosures with cylinders or manifolds, beverage dispensing installations, wine cellars, breweries and indoor areas where the gas is used or piped.\u003c\/p\u003e\n      \u003cp\u003eIts practical advantage is clear: it allows you to scale the system’s safety without redoing the entire installation, while keeping the existing LogiCO2 system wiring, signage and control logic.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"iblg90-cards\"\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eManufacturer’s part number\u003c\/strong\u003e\n          2119\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG004\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eFunction\u003c\/strong\u003e\n          Additional sensor for an existing LogiCO2 system\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eInitial setup\u003c\/strong\u003e\n          Preconfigured with ID2 address\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eCommunication\u003c\/strong\u003e\n          RS485 Modbus\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eBuilt-in alarm\u003c\/strong\u003e\n          Amber strobe sounder\/beacon included\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblg90-note\"\u003e\n        \u003cstrong\u003eImportant:\u003c\/strong\u003e this additional kit does not replace a base set. It requires an existing LogiCO2 Safety System, and the central unit must be configured for the actual number of connected sensors.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"iblg90-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eGenuine system expansion\u003c\/strong\u003e Allows you to add a new monitoring point to an existing LogiCO2 installation.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSensor with sounder\/beacon\u003c\/strong\u003e The Mk90 detector incorporates visual and audible warning to alert people in the area.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePreconfigured as ID2\u003c\/strong\u003e Supplied prepared as an additional sensor, which simplifies the initial expansion.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePowered from the existing system\u003c\/strong\u003e The kit is powered by the already installed LogiCO2 system, with no separate supply.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLocal on‑screen reading\u003c\/strong\u003e The sensor includes an LCD display for measurement and alarm information.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eNDIR detection\u003c\/strong\u003e Uses non‑dispersive infrared and a thermistor to measure CO2 and temperature.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAutomatic self-calibration\u003c\/strong\u003e Reduces the need for manual calibration under normal operating conditions.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eReady-to-install kit\u003c\/strong\u003e Includes cabling, RJ45 connectors, signage, protective cover and manual.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"iblg90-table-wrap\"\u003e\n        \u003ctable class=\"iblg90-table\"\u003e\n          \u003ccaption\u003eConfirmed technical specifications of the additional LogiCO2 Mk90 CO2 sensor kit\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eConfirmed data\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eCO2 Mk90 Sensor Add-on KIT \/ Mk90 CO2 sensor add-on kit\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG004\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e2119\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003eAdditional CO2 sensor with siren\/beacon to expand an existing LogiCO2 system\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIntended use\u003c\/th\u003e\n              \u003ctd\u003eExtension of an already installed LogiCO2 safety system\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCentral unit included\u003c\/th\u003e\n              \u003ctd\u003eNo\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eInitial setup\u003c\/th\u003e\n              \u003ctd\u003ePreconfigured with ID2 address\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n              \u003ctd\u003eThe kit is powered from the existing system. The kit datasheet states 12–24 V DC and the Mk90 sensor specification states 24 V DC.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n              \u003ctd\u003e117 mA peak\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConexiones de cableado\u003c\/th\u003e\n              \u003ctd\u003eRJ45\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDigital interface\u003c\/th\u003e\n              \u003ctd\u003eRS485 serial port Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOutputs\u003c\/th\u003e\n              \u003ctd\u003e2 x 24 V DC transistor output, minimum 1 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePantalla\u003c\/th\u003e\n              \u003ctd\u003eLCD\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAudible signal\u003c\/th\u003e\n              \u003ctd\u003eMk90: 80 dBa (1 m) maximum\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating principle\u003c\/th\u003e\n              \u003ctd\u003eInfrarrojo no dispersivo (NDIR) y termistor\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eRango de medición de CO2\u003c\/th\u003e\n              \u003ctd\u003e0-3 % vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eExtended CO2 range\u003c\/th\u003e\n              \u003ctd\u003e3-6,7 % vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModo de muestreo\u003c\/th\u003e\n              \u003ctd\u003eDifusión\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTWA\u003c\/th\u003e\n              \u003ctd\u003e8-hour calculation with 2-minute sampling interval\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePreconfigured levels\u003c\/th\u003e\n              \u003ctd\u003eInstant alert 5000 ppm; TWA 5000 ppm; low alarm 1.5%; high alarm 3.0%\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperature accuracy\u003c\/th\u003e\n              \u003ctd\u003e±1 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eResolución\u003c\/th\u003e\n              \u003ctd\u003e1 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAnnual zero-point drift\u003c\/th\u003e\n              \u003ctd\u003e\u003c 0.01% vol. with automatic self-calibration\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n              \u003ctd\u003e0 to +45 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eHumedad de funcionamiento\u003c\/th\u003e\n              \u003ctd\u003e0 a 95 % HR sin condensación\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWarm‑up time\u003c\/th\u003e\n              \u003ctd\u003e1 minuto a 22 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eVida útil del sensor\u003c\/th\u003e\n              \u003ctd\u003e\u003e 15 años\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOvervoltage\u003c\/th\u003e\n              \u003ctd\u003eCategory II\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePollution degree\u003c\/th\u003e\n              \u003ctd\u003eII\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n              \u003ctd\u003eIndoor use only\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eRelevant colour \/ finish\u003c\/th\u003e\n              \u003ctd\u003eStrobe sounder\/beacon with amber LED and protective cover included\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003eMk90 CO2 sensor, 10 m red cable, 5 m blue cable, amber strobe sounder\/beacon with 1 m cable, RJ45 1-1 splitter, RJ45 1-4 splitter, bag with 6 screws and plugs, signal sensor, strobe sounder\/beacon sign, Mk9\/Mk90 installation manual, Mk9\/Mk90 quick guide and protective cover.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eApprovals \/ compliance\u003c\/th\u003e\n              \u003ctd\u003eCE, UL certification, DIN6653-2:2015-06, EN55022:2006\/A1:2007, EN55024\/A2:2003, EN61000-3-2:2006, EN61000-3-3\/A2:2006, AS\/NZS CISPR 22:2006, IEC\/EN IT55022\/55024, LNE NF 128 certification rule and reference to OSHA PEL TWA for CO2.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThis kit is compatible with an existing LogiCO2 Safety System and is intended to add monitoring in another room, distribution point or risk area. The system’s central unit must be configured to receive measurements from the new sensor.\u003c\/p\u003e\n      \u003cp\u003eIt is used in indoor spaces where CO2 is used or stored and there is a possibility of accumulation due to leakage: technical rooms, cylinder areas, cold rooms, beverage dispensing installations, wine cellars, breweries and other confined areas.\u003c\/p\u003e\n      \u003cp\u003eIf the area has several entrances, more than one sounder\/beacon may be required so that the alarm is clearly visible from all access points.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"iblg90-bullets\"\u003e\n        \u003cli\u003eCheck that you already have an operational LogiCO2 safety system. This kit does not include a central unit.\u003c\/li\u003e\n        \u003cli\u003eThe central unit must be configured for the actual number of connected sensors and this kit comes preconfigured as ID2.\u003c\/li\u003e\n        \u003cli\u003eThe sensor must be installed at a maximum height of 30 cm from the floor and at a maximum distance of 5 m from the CO2 distribution point.\u003c\/li\u003e\n        \u003cli\u003eEach sensor covers a maximum area of 78 m²; if the area is larger or has several risk points, consider additional sensors.\u003c\/li\u003e\n        \u003cli\u003eThe siren\/beacon must be mounted above the sensor, about 2–2.4 m from the floor, clearly visible from any entrance to the monitored area.\u003c\/li\u003e\n        \u003cli\u003eIf there are additional doors or multiple entrances, a second sounder\/beacon may be required outside the monitored area.\u003c\/li\u003e\n        \u003cli\u003eUse original splitters and connectors and protect the RJ45 connectors from moisture and dust as per the manual.\u003c\/li\u003e\n        \u003cli\u003eIt is an indoor-use product and the installation should be carried out with technical criteria and clearly visible signage.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eThe sensor performs automatic self-calibration at regular intervals, which reduces the need for manual calibration in a normal environment. Even so, as this is a safety product, it is recommended to perform a functional check at least once a year.\u003c\/p\u003e\n      \u003cp\u003eIn real-world use, it is advisable to periodically check the sensor mounting, the condition of the red and blue wiring, the RJ45 connectors, the visibility of the siren\/beacon, and the presence of clearly legible signage next to the unit.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes this kit work on its own?\u003c\/summary\u003e\n        \u003cp\u003eNo. It is an additional sensor to expand an existing LogiCO2 Safety System.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes it include a central unit or a separate power supply?\u003c\/summary\u003e\n        \u003cp\u003eDoes not include central unit. The additional sensor is powered from the existing system.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eHow is it configured from the factory?\u003c\/summary\u003e\n        \u003cp\u003eIt comes preconfigured with ID2 address, so the central unit must be adjusted to the new number of connected sensors.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Dónde debe instalarse el sensor Mk90?\u003c\/summary\u003e\n        \u003cp\u003eIt must be installed at a maximum of 30 cm from the floor and a maximum of 5 m from the CO2 distribution point. Each sensor covers up to 78 m².\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhere is the sounder\/beacon mounted?\u003c\/summary\u003e\n        \u003cp\u003eIt must be placed above the sensor, approximately 2–2.4 m from the floor and visible from any entrance to the monitored area.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Necesita calibración manual periódica?\u003c\/summary\u003e\n        \u003cp\u003eUnder normal conditions no, because the sensor performs automatic self-calibration. Even so, an annual functional check is recommended.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"iblg90-download-grid\"\u003e\n        \u003ca class=\"iblg90-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/CO2_Mk90_Sensor_AddonKIT_2119_es_db_LogiCO2.pdf?v=1775031123\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eLogiCO2 2119 data sheet\u003c\/a\u003e\n        \u003ca class=\"iblg90-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManual Mk9 \/ Mk90\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57237641003356,"sku":"LG004","price":41100.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2-mk90sensor-kit-logico2.webp?v=1775034516","url":"https:\/\/installbeer.com\/en-in\/products\/additional-kit-co2-sensor-logico2-mk90-alarm","provider":"Install Beer","version":"1.0","type":"link"}