John Guest check valve · single check valve, imperial range image

Non-Return Valve

1/4''
10.52€ excl. VAT 12.94€ VAT incl.
Skip directly to product information
John Guest check valve · single check valve, imperial range image

Non-Return Valve

JG0026
10.52€ excl. VAT 12.94€ VAT incl.
EU businesses with a valid VAT number may qualify for a VAT-exempt intra-Community supply, subject to validation and applicable conditions.
Shipping calculated at checkout.
Tube size
Shipping information Request technical advice

Description

Inline push-fit check valve for the same tube outside diameter at both ends. It allows flow in one direction and limits reverse flow. The 15DCV is a double check valve.

Sizes and part numbers

Tube outside diameterJohn GuestSCV / DCVSKU
1/4″1/4SCVSingleJG0026
5/16″5/16SCVSingleIB0589
3/8″3/8SCVSingleIB0588
1/2″1/2SCVSingleJG0027
10 mm10SCVSingleJG0023
12 mm12SCVSingleJG0039
15 mm15DCVDoubleJG0057

Installation

Isolate and depressurise the line. Follow the flow arrow, cut the tubes square, deburr and push both ends fully home. Check flow and leaks before use. Consult the relevant data sheet for fluid compatibility and operating limits.

John Guest fittings guide

Technical documentation

View available combinations
  • JG0026 · 1/4''
  • IB0589 · 5/16''
  • IB0588 · 3/8"
  • JG0027 · 1/2''
  • JG0023 · 10mm
  • JG0039 · 12mm
  • JG0057 · 15mm

Useful accessories and add-ons

Check the correct connections and sizes.

Technical information

Information to choose, install and maintain this product

In-line valve designed to allow flow in one direction and limit return flow in the opposite direction within a compatible installation.

Typical applications

  • Used when you need to control the flow direction and reduce unwanted backflow within a line.
Technical specifications
Tube size
1/4″
Connection
Push-fit × push-fit · check valve
Installation and commissioning
Depressurize, identify the valve’s functional direction, cut the tubes straight and insert fully. Check operation and leak tightness before putting into service.
Maintenance
If you notice restriction or abnormal backflow, check the valve’s orientation, cleanliness and condition. Do not assume that a check valve replaces other safety devices in the system.
John Guest fitting guide
Manuals and downloads
Product FAQs
What sizes are available?
1/4″ · 5/16″ · 3/8″ · 1/2″ · 10 mm · 12 mm · 15 mm
Does it have a flow direction?
Yes, the functional direction must be respected.
Is it a shut-off valve?
No; its function is non-return.
What should I check if no fluid is passing through?
Orientation and possible obstructions.