Additional RCB kit with LogiCO2 relay delay function
Pickup available at Install Beer S.L.
Usually ready in 4 hours
LogiCO2 RCB with relay delay for external panels and ventilation
The RCB with LogiCO2 relay delay add‑on kit transmits pre‑alarm or high‑alarm signals to external devices, such as a fire alarm panel or a fan, with the option of direct activation or a 9.5‑second delay.
What this product offers
This accessory is intended for installations where the LogiCO2 system must not only give local warning, but also send the signal to external equipment. The manufacturer’s examples are clear: fire alarm panel or starting ventilation.
The operational advantage over a simple output is that it includes dedicated relays and a 9.5‑second delay, useful to avoid unwanted calls or trips during system testing.
In technical installations in hospitality, wineries, breweries, or the beverage industry, it is a useful component when the design requires integration with other safety or extraction equipment.
Key data
Main features
- Two independent relays Includes one relay dedicated to pre-alarm and another to high alarm.
- Volt‑free relays The documentation defines them as dry changeover relays.
- Useful delay for testing It can activate the relays with a 9.5‑second delay to avoid accidental alerts when testing the system.
- Flexible configuration The DIP switches allow each relay to be assigned to pre‑alarm or high alarm.
- Independent selection per relay Each relay can be configured separately.
- Normally‑energized or normally‑de‑energized mode The manufacturer allows you to choose whether the relay remains active in normal state or only during an alarm.
- External integration Designed to send a signal to a fire alarm panel or to start a fan.
- Compact format Small, protected electronic box for neat technical installations.
Technical specifications
| Parameter | Confirmed data |
|---|---|
| Brand | LogiCO2 |
| Model | RCB with relay delay Add-on KIT |
| SKU | LG016 |
| MPN / manufacturer part number | 0471 |
| Equipment type | Remote junction box for CO2 safety system |
| Function | Transmit alarm indications to external devices, for example a fire alarm panel or fan |
| Relays | 2 dedicated potential‑free (dry) changeover relays |
| Relay assignment | One for pre‑alarm and one for high alarm; you can also set both to pre‑alarm or both to high alarm |
| Activation | Instant or delayed 9.5 seconds |
| Power supply | Via the LogiCO2 sensor |
| Nominal relays | 1 A / 24 V AC/DC |
| Material | PC/ABS |
| Dimensions | 78 x 78 x 37 mm |
| Ingress protection | IP55 |
| Cable incluido | 1-meter CAT5 cable with blue RJ45 connector |
| Conexión de entrada | To the LogiCO2 sensor alarm output cable, also with blue RJ45 connector |
| Connection of the external device | Through the pre‑assembled cable gland |
| Scope of supply | Electronics box, 1‑meter cable and 1-to-4 RJ45 splitter |
| Weight | 500 g |
Compatibility and use cases
The RCB is designed as an accessory for LogiCO2 alarm systems and takes the signal from the sensor via the blue RJ45 connector.
Its clearest use case is integration with a fire alarm panel or with ventilation systems that must be activated when the system enters pre-alarm or high alarm.
It is particularly useful in projects where the CO2 safety system must interact with external equipment and not be limited to local warning from the sensor or central unit.
Installation and considerations before buying
- Install the box in a suitable location with mechanical protection.
- The cover is of the rotary type and opens 1/8 turn counterclockwise to access the mounting screw.
- Before purchasing, confirm whether your project really needs an external relay box or only a horn/strobe or local signaling.
- Check whether activation should be direct or with a 9.5-second delay.
- Also check whether the external equipment needs dry contacts or must receive V‑ or V+ on the common, because the manufacturer allows adjustments via jumpers.
- If you are going to connect it to a fire alarm panel, it’s advisable to define clearly which relay will operate on pre‑alarm and which on high alarm.
Recommended maintenance and use
As an integration accessory, it is advisable to periodically check the condition of the RJ45 cable, the mechanical mounting, the enclosure closure and the DIP-switch and jumper logic, especially after interventions or system expansions.
It is also advisable to carry out controlled activation tests to verify that the selected relay behaves with the expected logic and the correct delay.
Frequently asked questions
What exactly is the RCB used for?
It is used to transmit LogiCO2 system alarms to external equipment, for example a fire alarm panel or a fan.
Does it include two relays?
Yes. It has two dedicated dry relays, one for pre-alarm and one for high alarm, with the option to reconfigure them.
¿Qué retardo incorpora?
Allows delayed activation of 9.5 seconds.
Can you configure which relay operates on pre-alarm or high alarm?
Yes. The DIP-switch settings allow you to select that logic for each relay.
Is it a box with dry contacts?
Yes. The documentation describes it as having volt-free relays, i.e. dry relays.
¿Qué incluye el kit?
Includes the electronic box, a 1‑meter cable and an RJ45 1‑4 splitter.
Downloadable
Shipping: check availability, lead time and applicable cost before completing your order.
Terms: see the shipping, returns and warranty pages for the applicable conditions.
Structured technical information
Information to choose, install and maintain this product
Technical specifications
Select a variant to see its technical specifications.
- Tube size
- Thread
- Connection
- Blue RJ45
- Pressure
- Temperature
- Dimensions
- 78 × 78 × 37 mm