Additional LogiCO2 Mk9 O2 sensor kit with siren and wiring
Additional LogiCO2 Mk9 O2 sensor kit with siren and wiring
Pickup available at Install Beer S.L.
Usually ready in 4 hours
Additional LogiCO2 Mk9 O2 sensor kit to expand an existing system
The LogiCO2 Mk9 O2 sensor additional kit is a plug-and-play solution to add a second detection point to an already installed safety system, with O2 sensor, siren/beacon, cabling and signage included.
What this product offers
This kit is designed to extend an existing LogiCO2 system without having to install a complete new setup from scratch. Its function is to add an extra oxygen sensor with its own local signaling.
Its main advantage is that it comes preconfigured as an additional sensor, with ID2 address and power taken from the existing system. This simplifies expansion when the installation needs to monitor a second area.
At Install Beer, as official distributors in Europe and providers of installation and maintenance services, this type of kit is particularly suitable for extensions, safety upgrades, and evolutionary maintenance of installations that are already in operation.
Key data
Main features
- Complete expansion kit Includes O2 Mk9 sensor with display, siren/beacon, cables, connectors and signage.
- Plug-and-play format Supplied as an add-on kit to expand an already operating LogiCO2 system.
- Sensor preset to ID2 The manufacturer supplies it configured as an additional sensor with address ID2.
- Powered from the existing system Does not require its own separate power supply if the system is correctly sized.
- Optical O2 measurement The sensor uses an FB‑optical principle and measures oxygen concentration between 0 and 25%.
- Automatic self-calibration The sensor performs self-calibration at regular intervals under normal conditions.
- Backlit display Shows current O2 concentration and operating time in hours.
- Expandable up to 8 sensors The system can be expanded to up to eight connected sensors.
Technical specifications
| Parameter | Confirmed data |
|---|---|
| Brand | LogiCO2 |
| Model | O2 Mk9 Sensor Add-on KIT |
| SKU | LG019 |
| MPN / manufacturer part number | 2125 |
| Equipment type | Additional oxygen sensor kit for existing safety system |
| Factory configuration | Additional sensor preconfigured with address ID2 |
| Kit power supply | From the existing safety system |
| Maximum number of sensors in system | Up to 8 sensors |
| Preset alarm levels | Evacuation alarm: 19.5% O2; up to 3 different levels can be configured via DIP switches |
| Sensor included | O2 Sensor Mk9 |
| Sensor power supply | 24 V DC |
| Operating principle | Optical FB |
| Measuring range | 0 to 25% O2 |
| Precisión | <2% FS |
| Sensor LED indications | Green: operation · Yellow: fault · Red: alarm (<19.5% O2) |
| Sensor audible indications | Beep: fault · Continuous: alarm |
| Sensor display | Backlit; shows current O2 concentration and operating time in hours |
| Sensor dimensions | 90 x 161 x 38 mm |
| Sensor protection | IP54 |
| Siren/beacon included | Amber Horn/Strobe LED |
| Rated voltage, sounder/beacon | 18–24 V DC |
| Average current siren/beacon | 120 mA at 24 V DC |
| Siren/beacon sound level | 110 dB / 1 m (alarma alta) |
| Flash intensity | 115 CD (alarma baja) |
| Flash frequency | 65/min |
| Ambient temperature, sounder/beacon | -5 °C to +50 °C |
| Siren/beacon dimensions | 134 x 115 x 61 mm |
| Siren/beacon protection | IP65 |
| Scope of supply | O2 Mk9 detector + Horn/Strobe LED with cable + 10 m power/communication cable + plug lock + 5 m signaling cable + 1 RJ45 1-1 connector + 1 RJ45 1-4 connector + manual + H/S sign |
| Weight | 3 kg |
Compatibility and use cases
This kit is intended to add one more sensor to an existing LogiCO2 O2 safety system. It is especially useful when the installation grows or when a second area appears that also needs to be monitored.
It is suitable for plant rooms, cold rooms, areas with a risk of oxygen‑deficient atmosphere, nitrogen installations, and other environments where a single detection unit does not cover the entire risk area.
The documentation itself states that the central unit must be adjusted to the new total number of connected sensors.
Installation and considerations before buying
- The sensor must be installed at breathing height, between 150 and 180 cm from the floor.
- The siren/beacon must be mounted above the sensor, approximately 2–2.4 m from the floor and visible from any entrance.
- The central unit must be located outside the monitored area, in a visible and accessible point.
- Before purchasing, confirm that your existing system can accept an additional sensor and that the central unit can be reconfigured for the new number of sensors.
- Also verify that the system’s electrical sizing allows for expansion with this add‑on kit.
- If the system only has mechanical ventilation, the manual states that the room must have a sensor.
Recommended maintenance and use
The O2 Mk9 sensor performs automatic self-calibration at regular intervals, which reduces the need for manual calibration in a normal environment.
Even so, since this is a safety product, it is advisable to carry out periodic functional checks and, after installation, verify that the new sensor appears correctly on the control unit and that local signalling responds as it should.
Frequently asked questions
Is this kit suitable for installing a complete system from scratch?
No. It is designed as an additional sensor for an already existing LogiCO2 safety system.
How is it configured from the factory?
It comes preconfigured as ID2, i.e. as the second sensor in the system.
What exactly does the O2 MK9 kit include?
Includes O2 Mk9 sensor with display, sounder/beacon, cabling, RJ45 connectors, manual, and signage.
How many sensors can the LogiCO2 system handle?
The official page states that up to eight sensors can be connected.
Where should the O2 sensor be installed?
It must be installed at breathing height, between 150 and 180 cm from the floor.
What default alarm level does it come with?
The evacuation alarm is preset to 19.5% O2.
Downloadable
You may also be interested in
Shipping: check availability, lead time and applicable cost before completing your order.
Terms: see the shipping, returns and warranty pages for the applicable conditions.
Structured technical information
Information to choose, install and maintain this product
Technical specifications
Select a variant to see its technical specifications.
- Tube size
- Thread
- Connection
- RJ45 + LogiCO2 O2 Mk9
- Pressure
- Temperature
- Siren/beacon −5 °C to +50 °C
- Dimensions
- Sensor 90 × 161 × 38 mm; siren/beacon 134 × 115 × 61 mm