{"product_id":"conjunto-base-sensor-independiente-co2-logico2-mk90-alarma","title":"LogiCO2 Mk90 standalone CO2 sensor base set with alarm","description":"\u003csection class=\"iblg90-product iblg90-standalone\" data-brand=\"LogiCO2\" data-model=\"Mk90 Stand-Alone Base SET\"\u003e\n  \u003cstyle\u003e\n    .iblg90-product{\n      --iblg90-max:1120px;\n      --iblg90-text:#1f2328;\n      --iblg90-muted:#5b6573;\n      --iblg90-line:#e6e8eb;\n      --iblg90-soft:#f7f8fa;\n      --iblg90-soft2:#f2f4f6;\n      --iblg90-accent:#111111;\n      --iblg90-radius:18px;\n      --iblg90-shadow:0 12px 30px rgba(0,0,0,.05);\n      --iblg90-content-size:16px;\n      --iblg90-content-lh:1.68;\n      --iblg90-h2-size:28px;\n      --iblg90-h3-size:20px;\n      color:var(--iblg90-text);\n      font-size:var(--iblg90-content-size);\n      line-height:var(--iblg90-content-lh);\n    }\n    .iblg90-product *{box-sizing:border-box}\n    .iblg90-wrap{max-width:var(--iblg90-max);margin:0 auto;padding:4px 0 36px}\n    .iblg90-hero,.iblg90-block,.iblg90-specs,.iblg90-faq,.iblg90-downloads,.iblg90-related{\n      background:#fff;border:1px solid var(--iblg90-line);border-radius:var(--iblg90-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--iblg90-shadow)\n    }\n    .iblg90-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--iblg90-line);\n      border-radius:999px;background:var(--iblg90-soft);color:var(--iblg90-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblg90-product h2{\n      font-size:var(--iblg90-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--iblg90-accent)\n    }\n    .iblg90-product h3{\n      font-size:var(--iblg90-h3-size);line-height:1.28;margin:0 0 10px;color:var(--iblg90-accent)\n    }\n    .iblg90-product p{margin:0 0 14px;font-size:var(--iblg90-content-size);line-height:var(--iblg90-content-lh)}\n    .iblg90-product p:last-child{margin-bottom:0}\n    .iblg90-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--iblg90-soft);border:1px solid var(--iblg90-line)\n    }\n    .iblg90-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblg90-card{\n      padding:16px;border:1px solid var(--iblg90-line);border-radius:16px;background:var(--iblg90-soft)\n    }\n    .iblg90-card strong{display:block;margin-bottom:6px;color:var(--iblg90-accent)}\n    .iblg90-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--iblg90-accent);\n      background:var(--iblg90-soft2);border-radius:12px\n    }\n    .iblg90-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblg90-list-grid li{\n      padding:16px;border:1px solid var(--iblg90-line);border-radius:16px;background:#fff\n    }\n    .iblg90-list-grid li strong{display:block;margin-bottom:6px}\n    .iblg90-bullets{margin:0;padding-left:18px}\n    .iblg90-bullets li{margin:0 0 10px}\n    .iblg90-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblg90-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--iblg90-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblg90-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--iblg90-accent)\n    }\n    .iblg90-table thead th{\n      background:var(--iblg90-soft2);color:var(--iblg90-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--iblg90-line);font-size:15px\n    }\n    .iblg90-table tbody th,.iblg90-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--iblg90-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblg90-table tbody th{width:32%;background:#fcfcfd;font-weight:700;color:var(--iblg90-accent)}\n    .iblg90-table tbody tr:last-child th,.iblg90-table tbody tr:last-child td{border-bottom:none}\n    .iblg90-download-grid,.iblg90-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblg90-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--iblg90-accent);text-decoration:none;color:var(--iblg90-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblg90-btn:hover{transform:translateY(-1px);box-shadow:var(--iblg90-shadow)}\n    .iblg90-faq details{\n      border:1px solid var(--iblg90-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblg90-faq details:last-child{margin-bottom:0}\n    .iblg90-faq summary{cursor:pointer;font-weight:700;color:var(--iblg90-accent)}\n    .iblg90-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblg90-cards,.iblg90-list-grid,.iblg90-download-grid,.iblg90-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblg90-product{\n        --iblg90-content-size:15px;\n        --iblg90-h2-size:23px;\n        --iblg90-h3-size:18px;\n      }\n      .iblg90-hero,.iblg90-block,.iblg90-specs,.iblg90-faq,.iblg90-downloads,.iblg90-related{\n        padding:18px;border-radius:16px\n      }\n      .iblg90-table{min-width:100%;border:0}\n      .iblg90-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblg90-table,.iblg90-table tbody,.iblg90-table tr,.iblg90-table th,.iblg90-table td{\n        display:block;width:100%\n      }\n      .iblg90-table tr{\n        border:1px solid var(--iblg90-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblg90-table tbody th{\n        background:var(--iblg90-soft2);border-bottom:1px solid var(--iblg90-line)\n      }\n      .iblg90-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblg90-wrap\"\u003e\n    \u003cdiv class=\"iblg90-hero\"\u003e\n      \u003cdiv class=\"iblg90-kicker\"\u003eSeguridad CO2 · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 Mk90 stand-alone CO2 sensor for leak detection with built-in alarm\u003c\/h2\u003e\n      \u003cp class=\"iblg90-snippet\"\u003e\u003cstrong\u003eThe LogiCO2 Mk90 standalone CO2 sensor base set is an autonomous detector with integrated audible and visual alarm to monitor CO2 concentration in confined spaces and warn when unhealthy or hazardous levels are reached.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eQué aporta este producto\u003c\/h2\u003e\n      \u003cp\u003eThis unit addresses a very specific need: monitoring CO2 leaks in a risk area without relying on a central unit included in the set. That is why it works well as a standalone solution in spaces where CO2 is used or piped and a clear local alert is required.\u003c\/p\u003e\n      \u003cp\u003eIts practical value lies in bringing together in a single kit the Mk90 sensor, the strobe sounder\/beacon, the power supply, wiring and basic signage. This makes for a clean initial deployment and reduces complexity compared with configurations assembled piece by piece.\u003c\/p\u003e\n      \u003cp\u003eIn addition, the sensor includes integrated audible and visual indication, display, automatic self-calibration and manual altitude adjustment. If the installation is expanded in the future, the manufacturer states that this standalone sensor can be connected to the Mk9 central unit and to the Mk9 CO2 sensor set.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"iblg90-cards\"\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          2090\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG002\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eSystem type\u003c\/strong\u003e\n          Standalone sensor with local alarm\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003ePower supply for the set\u003c\/strong\u003e\n          12-24 V CC\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003eCommunication\u003c\/strong\u003e\n          Modbus protocol over RS485\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblg90-card\"\u003e\n          \u003cstrong\u003ePreset levels\u003c\/strong\u003e\n          5000 ppm, 1.5% and 3.0% CO2\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblg90-note\"\u003e\n        \u003cstrong\u003eImportant:\u003c\/strong\u003e this set operates as a standalone local detection system, but does not include a central unit. If the installation has multiple access points or several risk areas, additional signage or complementary components may be required.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"iblg90-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eStandalone operation\u003c\/strong\u003e The Mk90 is designed as an independent system to monitor a specific area, with no central unit included.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBuilt-in audible and visual alarm\u003c\/strong\u003e The sensor monitors CO2 and generates a local warning when configured alert or alarm levels are reached.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eRemote sounder\/beacon included\u003c\/strong\u003e The kit includes a strobe sounder\/beacon with amber glass and a 1-metre cable.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eNDIR detection\u003c\/strong\u003e The sensor uses non-dispersive infrared analysis and a thermistor to measure CO2 and temperature.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAutomatic self‑calibration\u003c\/strong\u003e The unit performs self‑calibration at regular intervals, reducing the need for manual calibration in a normal environment.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eManual altitude adjustment\u003c\/strong\u003e The Mk90 allows manual altitude adjustment to adapt the measurement to the installation.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDisplay and local readout\u003c\/strong\u003e The display alternates between CO2 concentration, TWA and temperature.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eConnectable to Mk9 systems\u003c\/strong\u003e The manufacturer states that it is compatible for connection with the Mk9 central unit and the Mk9 sensor set.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"iblg90-table-wrap\"\u003e\n        \u003ctable class=\"iblg90-table\"\u003e\n          \u003ccaption\u003eConfirmed technical specifications of the LogiCO2 Mk90 standalone base sensor set\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eCO2 Mk90 Stand-Alone Base SET \/ Stand-alone CO2 Mk90 Sensor Base Set\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG002\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ manufacturer part number\u003c\/th\u003e\n              \u003ctd\u003e2090\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003eStandalone CO2 detector with built-in audible and visual alarm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConfiguración del conjunto\u003c\/th\u003e\n              \u003ctd\u003eMk90 sensor + strobe sounder\/beacon + power supply + cabling + signage + protective cover\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePower supply for the set\u003c\/th\u003e\n              \u003ctd\u003e12-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAlimentación del sensor\u003c\/th\u003e\n              \u003ctd\u003e24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConsumo del sensor\u003c\/th\u003e\n              \u003ctd\u003e56 mA without alarm; 117 mA in alarm state\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSounder\/beacon power consumption\u003c\/th\u003e\n              \u003ctd\u003e60 mA peak with 24 V DC supply\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCommunication\u003c\/th\u003e\n              \u003ctd\u003eModbus protocol over RS485\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eConexiones de cableado\u003c\/th\u003e\n              \u003ctd\u003eRJ45\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSalidas\u003c\/th\u003e\n              \u003ctd\u003e2 x 24 V DC transistor outputs, minimum 1 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePantalla\u003c\/th\u003e\n              \u003ctd\u003eLCD\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating principle\u003c\/th\u003e\n              \u003ctd\u003eNon-dispersive infrared (NDIR) and thermistor\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eRango de medición de CO2\u003c\/th\u003e\n              \u003ctd\u003e0–3% vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGama ampliada de CO2\u003c\/th\u003e\n              \u003ctd\u003e3-6,7 % vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSampling mode\u003c\/th\u003e\n              \u003ctd\u003eDifusión\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTWA\u003c\/th\u003e\n              \u003ctd\u003e8‑hour time‑weighted average with 2‑minute sampling period\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePreset levels\u003c\/th\u003e\n              \u003ctd\u003e5000 ppm awareness indication; 5000 ppm TWA\/8 h alarm; 1.5% low alarm 1\/2 STEL; 3.0% high alarm STEL\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePrecisión CO2\u003c\/th\u003e\n              \u003ctd\u003e±200 ppm ±10% of reading\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperature accuracy\u003c\/th\u003e\n              \u003ctd\u003e±1 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eResolución\u003c\/th\u003e\n              \u003ctd\u003eCO2: 0,01 % vol. · Temperatura: 1 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor operating temperature\u003c\/th\u003e\n              \u003ctd\u003e0 a +45 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor operating humidity\u003c\/th\u003e\n              \u003ctd\u003e0 to 95% RH non-condensing\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTiempo de calentamiento\u003c\/th\u003e\n              \u003ctd\u003e1 minute at 22 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eVida útil del sensor\u003c\/th\u003e\n              \u003ctd\u003e\u003e 15 years\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor dimensions\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eProtección del sensor\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eHorn\/strobe rated voltage\u003c\/th\u003e\n              \u003ctd\u003e18-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIntensidad acústica\u003c\/th\u003e\n              \u003ctd\u003eMk90: 80 dBa (1 m) max · Horn\/strobe: 110 dB at 1 m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFlash intensity\u003c\/th\u003e\n              \u003ctd\u003e115 CD\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFlash frequency\u003c\/th\u003e\n              \u003ctd\u003e65\/min\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSounder\/beacon ambient temperature\u003c\/th\u003e\n              \u003ctd\u003e-5 to +50 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSounder\/beacon dimensions\u003c\/th\u003e\n              \u003ctd\u003e134 x 115 x 61 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSiren\/beacon protection\u003c\/th\u003e\n              \u003ctd\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAdditional setting\u003c\/th\u003e\n              \u003ctd\u003eManual altitude adjustment\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUso\u003c\/th\u003e\n              \u003ctd\u003eSolo para interiores\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003eMk90 CO2 sensor with one 10 m blue cable and one 5 m red cable, strobe horn with amber LED glass and blue indicator with 1 m cable and sign, RJ45 1-1 splitter, 1 A transformer, plug lock, bag with gaskets, ties, screws and plugs, Mk90 sensor sign, horn\/strobe sign, Mk90 installation manual, Mk90 quick guide and protective cover.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eApprovals and compliance\u003c\/th\u003e\n              \u003ctd\u003eCE, DIN6653-2 2015-06, UL certified, EN55022:2006\/A1:2007, EN55024\/A2:2003, EN61000-3-2:2006, EN61000-3-3\/A2:2006, AS\/NZS CISPR 22:2006, IEC\/EN IT55022\/55024, LNE Certification Rule NF 128.\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThis set is intended for indoor spaces where CO2 is used or distributed and accumulation may occur due to leaks. It is suitable for hospitality, wineries, breweries, plant rooms, cold rooms, bottle areas, dispensing points and other confined spaces.\u003c\/p\u003e\n      \u003cp\u003eAs a stand‑alone system, it is especially useful when direct local protection is needed in a single area. The manufacturer also states that the Mk90 Stand‑Alone sensor can be connected to the Mk9 central unit and the Mk9 CO2 sensor set, allowing it to be integrated into a larger installation.\u003c\/p\u003e\n      \u003cp\u003eIf the room has several entrances, the manual itself states that more than one strobe siren\/beacon may be required to ensure alarm visibility from all access points.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"iblg90-bullets\"\u003e\n        \u003cli\u003eInstall the sensor at a maximum height of 30 cm from the floor and at a maximum distance of 5 m from the CO2 distribution point.\u003c\/li\u003e\n        \u003cli\u003eEach sensor covers a maximum area of 78 m²; if the room is larger or has several risk points, consider an expanded solution.\u003c\/li\u003e\n        \u003cli\u003eThe siren\/beacon must be installed above the sensor, approximately 2–2.4 m from the floor and clearly visible from any entrance.\u003c\/li\u003e\n        \u003cli\u003eThe manual states that a second sounder\/beacon outside the monitored area may also be advisable, preferably above the access door or doors.\u003c\/li\u003e\n        \u003cli\u003eUse original RJ45 wiring and connectors and protect connectors and splitters from moisture and dust with the supplied accessories.\u003c\/li\u003e\n        \u003cli\u003eThe separate power supply must be connected with the appropriate plug adapter for the country and installed with the included plug lock.\u003c\/li\u003e\n        \u003cli\u003eThe product is for indoor use, and the signage should be mounted permanently and clearly visible next to or above the units.\u003c\/li\u003e\n        \u003cli\u003eIf the installation only has mechanical ventilation, the manual states that it must have a sensor.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eThe Mk90 performs self-calibration at regular intervals, which under normal conditions eliminates the need for manual calibration. Even so, as it is safety equipment, it is advisable to periodically verify operation, signage visibility, cable condition and alarm response.\u003c\/p\u003e\n      \u003cp\u003eIn real-world use, you should avoid impacts, boxes or moving elements that could damage the sensor installed at low height. The front of the detector must also be kept clear so as not to affect detection and local reading.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes this set work without a central unit?\u003c\/summary\u003e\n        \u003cp\u003eYes. It is a stand‑alone local detection system with integrated alarm and built‑in sounder\/beacon.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes it include sounder\/beacon and power supply?\u003c\/summary\u003e\n        \u003cp\u003eYes. Set 2090 includes a strobe sounder\/beacon, power supply, wiring, connectors, manual and signage.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhere should the Mk90 sensor be installed?\u003c\/summary\u003e\n        \u003cp\u003eIt must be installed at a maximum height of 30 cm from the floor and at a maximum distance of 5 m from the CO2 distribution point. Each sensor covers up to 78 m².\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Dónde se monta la sirena\/baliza?\u003c\/summary\u003e\n        \u003cp\u003eDebe colocarse sobre el sensor, aproximadamente a 2-2,4 m del suelo y visible desde cualquier entrada a la zona vigilada.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCan it be connected to a larger LogiCO2 system?\u003c\/summary\u003e\n        \u003cp\u003eYes. The manufacturer states that the Mk90 Stand-Alone can be connected to the Mk9 central unit and to the Mk9 CO2 sensor set.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Necesita calibración manual periódica?\u003c\/summary\u003e\n        \u003cp\u003eUnder normal conditions no, because the unit performs automatic self-calibration. Even so, periodic functional checks are advisable.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"iblg90-download-grid\"\u003e\n        \u003ca class=\"iblg90-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/CO2_Mk90_Sensors_BaseSET_2090_es_db_LogiCO2_5ec71203-d8a8-412e-804c-9058b4677845.pdf?v=1775032527\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eLogiCO2 2090 data sheet\u003c\/a\u003e\n        \u003ca class=\"iblg90-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManual Mk9 \/ Mk90\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblg90-related\"\u003e\n      \u003ch2\u003eTambién puede interesarte\u003c\/h2\u003e\n      \u003cdiv class=\"iblg90-related-grid\"\u003e\n        \u003ca class=\"iblg90-btn\" href=\"\/en-eea\/collections\/alarmas-detectores-co2-logico2\"\u003eAlarmas y detectores de CO2 LogiCO2\u003c\/a\u003e\n        \u003ca class=\"iblg90-btn\" href=\"\/en-eea\/pages\/servicio-tecnico\"\u003eAsesoramiento e instalación técnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57237639692636,"sku":"LG002","price":360.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2-mk90standalone-alarm-glow-set-logico2.webp?v=1775034507","url":"https:\/\/installbeer.com\/en-eea\/products\/stand-alone-base-set-co2-sensor-logico2-mk90-alarm","provider":"Install Beer","version":"1.0","type":"link"}