Kit adicional de sensor de CO2 LogiCO2 Mk90 con alarma - Install Beer

Additional LogiCO2 Mk90 CO2 sensor kit with alarm

360.00€ EUR tax excl.
Skip directly to product information
Kit adicional de sensor de CO2 LogiCO2 Mk90 con alarma - Install Beer

Additional LogiCO2 Mk90 CO2 sensor kit with alarm

LG004
360.00€ EUR tax excl.
Import information for Kosovo Duties, import taxes and handling fees depend on the destination. Calculated amounts, where applicable, will be shown at checkout; customs or the carrier may collect charges that are not included.
Shipping calculated at checkout.

Pickup available at Install Beer S.L.

Usually ready in 4 hours

View store information

Additional LogiCO2 Mk90 CO2 sensor kit with alarm

Install Beer S.L.

Pickup available, usually ready in 4 hours

Carrer de Joaquim Valls 109
Local
08042 Barcelona
B
Spain

+34933464656
Seguridad CO2 · LogiCO2

Additional LogiCO2 Mk90 CO2 sensor kit to expand an existing system

The additional LogiCO2 Mk90 CO2 sensor kit adds a new detection point with sounder/beacon to an already installed LogiCO2 system to monitor CO2 leaks in technical rooms, cold rooms or dispensing areas with a risk of accumulation.

Qué aporta este producto

This kit is designed to expand an existing LogiCO2 safety system. It is not a standalone set with a central unit, but an additional sensor with visual and audible alarm to cover another risk area or a new CO2 distribution point.

It is especially suitable for installations where CO2 can accumulate due to leakage: technical rooms, enclosures with cylinders or manifolds, beverage dispensing installations, wine cellars, breweries and indoor areas where the gas is used or piped.

Its practical advantage is clear: it allows you to scale the system’s safety without redoing the entire installation, while keeping the existing LogiCO2 system wiring, signage and control logic.

Key data

Manufacturer’s part number 2119
SKU Install Beer LG004
Function Additional sensor for an existing LogiCO2 system
Initial setup Preconfigured with ID2 address
Communication RS485 Modbus
Built-in alarm Amber strobe sounder/beacon included
Important: this additional kit does not replace a base set. It requires an existing LogiCO2 Safety System, and the central unit must be configured for the actual number of connected sensors.

Main features

  • Genuine system expansion Allows you to add a new monitoring point to an existing LogiCO2 installation.
  • Sensor with sounder/beacon The Mk90 detector incorporates visual and audible warning to alert people in the area.
  • Preconfigured as ID2 Supplied prepared as an additional sensor, which simplifies the initial expansion.
  • Powered from the existing system The kit is powered by the already installed LogiCO2 system, with no separate supply.
  • Local on‑screen reading The sensor includes an LCD display for measurement and alarm information.
  • NDIR detection Uses non‑dispersive infrared and a thermistor to measure CO2 and temperature.
  • Automatic self-calibration Reduces the need for manual calibration under normal operating conditions.
  • Ready-to-install kit Includes cabling, RJ45 connectors, signage, protective cover and manual.

Technical specifications

Confirmed technical specifications of the additional LogiCO2 Mk90 CO2 sensor kit
Parámetro Confirmed data
Brand LogiCO2
Model CO2 Mk90 Sensor Add-on KIT / Mk90 CO2 sensor add-on kit
SKU LG004
MPN / artículo fabricante 2119
Equipment type Additional CO2 sensor with siren/beacon to expand an existing LogiCO2 system
Intended use Extension of an already installed LogiCO2 safety system
Central unit included No
Initial setup Preconfigured with ID2 address
Power supply The kit is powered from the existing system. The kit datasheet states 12–24 V DC and the Mk90 sensor specification states 24 V DC.
Power consumption 117 mA peak
Conexiones de cableado RJ45
Digital interface RS485 serial port Modbus
Outputs 2 x 24 V DC transistor output, minimum 1 mA
Pantalla LCD
Audible signal Mk90: 80 dBa (1 m) maximum
Operating principle Infrarrojo no dispersivo (NDIR) y termistor
Rango de medición de CO2 0-3 % vol.
Extended CO2 range 3-6,7 % vol.
Modo de muestreo Difusión
TWA 8-hour calculation with 2-minute sampling interval
Preconfigured levels Instant alert 5000 ppm; TWA 5000 ppm; low alarm 1.5%; high alarm 3.0%
Temperature accuracy ±1 °C
Resolución 1 °C
Annual zero-point drift < 0.01% vol. with automatic self-calibration
Operating temperature 0 to +45 °C
Humedad de funcionamiento 0 a 95 % HR sin condensación
Warm‑up time 1 minuto a 22 °C
Vida útil del sensor > 15 años
Dimensions 90 x 161 x 38 mm
Ingress protection IP54
Overvoltage Category II
Pollution degree II
Use Indoor use only
Relevant colour / finish Strobe sounder/beacon with amber LED and protective cover included
Scope of supply Mk90 CO2 sensor, 10 m red cable, 5 m blue cable, amber strobe sounder/beacon with 1 m cable, RJ45 1-1 splitter, RJ45 1-4 splitter, bag with 6 screws and plugs, signal sensor, strobe sounder/beacon sign, Mk9/Mk90 installation manual, Mk9/Mk90 quick guide and protective cover.
Approvals / compliance CE, UL certification, DIN6653-2:2015-06, EN55022:2006/A1:2007, EN55024/A2:2003, EN61000-3-2:2006, EN61000-3-3/A2:2006, AS/NZS CISPR 22:2006, IEC/EN IT55022/55024, LNE NF 128 certification rule and reference to OSHA PEL TWA for CO2.
Weight Dato no facilitado

Compatibility and use cases

This kit is compatible with an existing LogiCO2 Safety System and is intended to add monitoring in another room, distribution point or risk area. The system’s central unit must be configured to receive measurements from the new sensor.

It is used in indoor spaces where CO2 is used or stored and there is a possibility of accumulation due to leakage: technical rooms, cylinder areas, cold rooms, beverage dispensing installations, wine cellars, breweries and other confined areas.

If the area has several entrances, more than one sounder/beacon may be required so that the alarm is clearly visible from all access points.

Installation and considerations before buying

  • Check that you already have an operational LogiCO2 safety system. This kit does not include a central unit.
  • The central unit must be configured for the actual number of connected sensors and this kit comes preconfigured as ID2.
  • The sensor must be installed at a maximum height of 30 cm from the floor and at a maximum distance of 5 m from the CO2 distribution point.
  • Each sensor covers a maximum area of 78 m²; if the area is larger or has several risk points, consider additional sensors.
  • The siren/beacon must be mounted above the sensor, about 2–2.4 m from the floor, clearly visible from any entrance to the monitored area.
  • If there are additional doors or multiple entrances, a second sounder/beacon may be required outside the monitored area.
  • Use original splitters and connectors and protect the RJ45 connectors from moisture and dust as per the manual.
  • It is an indoor-use product and the installation should be carried out with technical criteria and clearly visible signage.

Recommended maintenance and use

The sensor performs automatic self-calibration at regular intervals, which reduces the need for manual calibration in a normal environment. Even so, as this is a safety product, it is recommended to perform a functional check at least once a year.

In real-world use, it is advisable to periodically check the sensor mounting, the condition of the red and blue wiring, the RJ45 connectors, the visibility of the siren/beacon, and the presence of clearly legible signage next to the unit.

Frequently asked questions

Does this kit work on its own?

No. It is an additional sensor to expand an existing LogiCO2 Safety System.

Does it include a central unit or a separate power supply?

Does not include central unit. The additional sensor is powered from the existing system.

How is it configured from the factory?

It comes preconfigured with ID2 address, so the central unit must be adjusted to the new number of connected sensors.

¿Dónde debe instalarse el sensor Mk90?

It must be installed at a maximum of 30 cm from the floor and a maximum of 5 m from the CO2 distribution point. Each sensor covers up to 78 m².

Where is the sounder/beacon mounted?

It must be placed above the sensor, approximately 2–2.4 m from the floor and visible from any entrance to the monitored area.

¿Necesita calibración manual periódica?

Under normal conditions no, because the sensor performs automatic self-calibration. Even so, an annual functional check is recommended.

Shipping: check availability, lead time and applicable cost before completing your order.

Terms: see the shipping, returns and warranty pages for the applicable conditions.

Buy technical products with confidence

Confirm compatibility before purchasing

With dispensing components, a few millimetres, a thread or the beverage type can determine compatibility. Review the description and contact us when you do not have all the details.

01

Application

Beverage, location, expected flow and installation type.

02

Connection

Thread, hose barb, push-fit connector, internal and external diameter.

03

Conditions

Pressure, gas, temperature, material and cleaning requirements.

04

Contents

Check which accessories, seals or adapters are included.