{"product_id":"sensor-co2-logico2-mk9","title":"LogiCO2 Mk9 CO2 sensor add-on kit","description":"\u003csection class=\"ibco2mk9-product ibco2mk9-1134\" data-brand=\"LogiCO2\" data-model=\"CO2 Sensor Mk9\"\u003e\n  \u003cstyle\u003e\n    .ibco2mk9-product{\n      --ib-max:1120px;\n      --ib-text:#1f2328;\n      --ib-muted:#5b6573;\n      --ib-line:#e6e8eb;\n      --ib-soft:#f7f8fa;\n      --ib-soft2:#f2f4f6;\n      --ib-accent:#111111;\n      --ib-radius:18px;\n      --ib-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ib-content-size:16px;\n      --ib-content-lh:1.68;\n      --ib-h2-size:28px;\n      --ib-h3-size:20px;\n      color:var(--ib-text);\n      font-size:var(--ib-content-size);\n      line-height:var(--ib-content-lh);\n    }\n    .ibco2mk9-product *{box-sizing:border-box}\n    .ibco2mk9-wrap{max-width:var(--ib-max);margin:0 auto;padding:4px 0 36px}\n    .ibco2mk9-hero,.ibco2mk9-block,.ibco2mk9-specs,.ibco2mk9-faq,.ibco2mk9-downloads,.ibco2mk9-related{\n      background:#fff;border:1px solid var(--ib-line);border-radius:var(--ib-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ib-shadow)\n    }\n    .ibco2mk9-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ib-line);\n      border-radius:999px;background:var(--ib-soft);color:var(--ib-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibco2mk9-product h2{\n      font-size:var(--ib-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ib-accent)\n    }\n    .ibco2mk9-product h3{\n      font-size:var(--ib-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ib-accent)\n    }\n    .ibco2mk9-product p{margin:0 0 14px;font-size:var(--ib-content-size);line-height:var(--ib-content-lh)}\n    .ibco2mk9-product p:last-child{margin-bottom:0}\n    .ibco2mk9-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ib-soft);border:1px solid var(--ib-line)\n    }\n    .ibco2mk9-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibco2mk9-card{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:var(--ib-soft)\n    }\n    .ibco2mk9-card strong{display:block;margin-bottom:6px;color:var(--ib-accent)}\n    .ibco2mk9-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ib-accent);\n      background:var(--ib-soft2);border-radius:12px\n    }\n    .ibco2mk9-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibco2mk9-list-grid li{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:#fff\n    }\n    .ibco2mk9-list-grid li strong{display:block;margin-bottom:6px}\n    .ibco2mk9-bullets{margin:0;padding-left:18px}\n    .ibco2mk9-bullets li{margin:0 0 10px}\n    .ibco2mk9-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibco2mk9-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ib-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibco2mk9-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ib-accent)\n    }\n    .ibco2mk9-table thead th{\n      background:var(--ib-soft2);color:var(--ib-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);font-size:15px\n    }\n    .ibco2mk9-table tbody th,.ibco2mk9-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibco2mk9-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ib-accent)}\n    .ibco2mk9-table tbody tr:last-child th,.ibco2mk9-table tbody tr:last-child td{border-bottom:none}\n    .ibco2mk9-download-grid,.ibco2mk9-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibco2mk9-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ib-accent);text-decoration:none;color:var(--ib-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibco2mk9-btn:hover{transform:translateY(-1px);box-shadow:var(--ib-shadow)}\n    .ibco2mk9-faq details{\n      border:1px solid var(--ib-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibco2mk9-faq details:last-child{margin-bottom:0}\n    .ibco2mk9-faq summary{cursor:pointer;font-weight:700;color:var(--ib-accent)}\n    .ibco2mk9-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibco2mk9-cards,.ibco2mk9-list-grid,.ibco2mk9-download-grid,.ibco2mk9-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibco2mk9-product{\n        --ib-content-size:15px;\n        --ib-h2-size:23px;\n        --ib-h3-size:18px;\n      }\n      .ibco2mk9-hero,.ibco2mk9-block,.ibco2mk9-specs,.ibco2mk9-faq,.ibco2mk9-downloads,.ibco2mk9-related{\n        padding:18px;border-radius:16px\n      }\n      .ibco2mk9-table{min-width:100%;border:0}\n      .ibco2mk9-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibco2mk9-table,.ibco2mk9-table tbody,.ibco2mk9-table tr,.ibco2mk9-table th,.ibco2mk9-table td{\n        display:block;width:100%\n      }\n      .ibco2mk9-table tr{\n        border:1px solid var(--ib-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibco2mk9-table tbody th{\n        background:var(--ib-soft2);border-bottom:1px solid var(--ib-line)\n      }\n      .ibco2mk9-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibco2mk9-wrap\"\u003e\n    \u003cdiv class=\"ibco2mk9-hero\"\u003e\n      \u003cdiv class=\"ibco2mk9-kicker\"\u003eCO2 Safety · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 Mk9 CO2 sensor to extend or replace a detection point\u003c\/h2\u003e\n      \u003cp class=\"ibco2mk9-snippet\"\u003e\u003cstrong\u003eThe LogiCO2 Mk9 CO2 Sensor measures CO2 concentration, displays the values on screen and generates an alert when the configured alarm levels are reached. It is a suitable solution as a replacement or expansion within an existing LogiCO2 system.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibco2mk9-block\"\u003e\n      \u003ch2\u003eWhat this product offers\u003c\/h2\u003e\n      \u003cp\u003eThis sensor is designed to monitor CO2 concentration in an enclosed space and warn when potentially dangerous levels are reached. It can operate connected to a LogiCO2 central unit or be integrated into a broader monitoring system.\u003c\/p\u003e\n      \u003cp\u003eIts NDIR technology, MODBUS communication and automatic self-calibration make it a solid technical option for hospitality, wineries, breweries, technical rooms and other environments where CO2 is used or stored.\u003c\/p\u003e\n      \u003cp\u003eAt Install Beer, as official distributors in Europe and providers of installation and maintenance services, this type of sensor is particularly suitable for extensions, replacements, and maintenance of LogiCO2 systems.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibco2mk9-block\"\u003e\n      \u003ch2\u003eKey data\u003c\/h2\u003e\n      \u003cdiv class=\"ibco2mk9-cards\"\u003e\n        \u003cdiv class=\"ibco2mk9-card\"\u003e\n          \u003cstrong\u003eManufacturer’s part number\u003c\/strong\u003e\n          1134\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibco2mk9-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG020\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibco2mk9-card\"\u003e\n          \u003cstrong\u003eType\u003c\/strong\u003e\n          CO2 sensor with display and alarm\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibco2mk9-card\"\u003e\n          \u003cstrong\u003eMeasuring range\u003c\/strong\u003e\n          0–3% vol.\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibco2mk9-card\"\u003e\n          \u003cstrong\u003eExtended range\u003c\/strong\u003e\n          3–6.7% vol.\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibco2mk9-card\"\u003e\n          \u003cstrong\u003eCommunication\u003c\/strong\u003e\n          RS485 MODBUS\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibco2mk9-block\"\u003e\n      \u003ch2\u003eMain features\u003c\/h2\u003e\n      \u003cul class=\"ibco2mk9-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCO2 measurement by NDIR\u003c\/strong\u003e Uses non‑dispersive infrared and a thermistor to control CO2 concentration.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIntegrated display\u003c\/strong\u003e Shows CO2, TWA and temperature when the thermal function is enabled.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLocal audible alarm\u003c\/strong\u003e Includes an audible warning when an alarm level is reached.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eProfessional connectivity\u003c\/strong\u003e Communicates via RS485 MODBUS.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAutomatic self-calibration\u003c\/strong\u003e Performs periodic self-calibration under normal conditions.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAvailable outputs\u003c\/strong\u003e Integrates 2 x 24 V DC transistor outputs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompatible with control unit\u003c\/strong\u003e Can be connected to the LogiCO2 central unit.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUse as spare or expansion\u003c\/strong\u003e The official package includes the Mk9 CO2 detector as a standalone unit.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibco2mk9-specs\"\u003e\n      \u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n      \u003cdiv class=\"ibco2mk9-table-wrap\"\u003e\n        \u003ctable class=\"ibco2mk9-table\"\u003e\n          \u003ccaption\u003eTechnical specifications of the LogiCO2 Mk9 CO2 Sensor\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eData\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n              \u003ctd\u003eCO2 Sensor Mk9\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG020\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ manufacturer part number\u003c\/th\u003e\n              \u003ctd\u003e1134\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n              \u003ctd\u003eCO2 sensor for safety system\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n              \u003ctd\u003e24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePower consumption\u003c\/th\u003e\n              \u003ctd\u003e\u0026lt;300 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWiring connections\u003c\/th\u003e\n              \u003ctd\u003eRJ45\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDigital interface\u003c\/th\u003e\n              \u003ctd\u003eRS485 MODBUS serial\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOutputs\u003c\/th\u003e\n              \u003ctd\u003e2 transistor outputs 24 V DC, min. 1 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAudible signal\u003c\/th\u003e\n              \u003ctd\u003e85 dB(A) (1 m) max.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating principle\u003c\/th\u003e\n              \u003ctd\u003eNDIR and thermistor\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCO2 measuring range\u003c\/th\u003e\n              \u003ctd\u003e0–3% vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eExtended CO2 range\u003c\/th\u003e\n              \u003ctd\u003e3–6.7% vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSampling mode\u003c\/th\u003e\n              \u003ctd\u003eDiffusion\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTWA\u003c\/th\u003e\n              \u003ctd\u003eCalculation over 8 hours with a 2-minute sampling period\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n              \u003ctd\u003e0.01 % vol.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCO2 accuracy\u003c\/th\u003e\n              \u003ctd\u003e±200 ppm ±10% of reading\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAnnual zero-point drift\u003c\/th\u003e\n              \u003ctd\u003e\u0026lt;0.01% vol. with automatic self‑calibration\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n              \u003ctd\u003e0–45 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eOperating humidity\u003c\/th\u003e\n              \u003ctd\u003e0 to 95% RH non-condensing\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWarm‑up time\u003c\/th\u003e\n              \u003ctd\u003e1 min at 22 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensor service life\u003c\/th\u003e\n              \u003ctd\u003e\u003e15 years\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n              \u003ctd\u003eØ 90 × 120 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n              \u003ctd\u003eIP56\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePreset alarm levels\u003c\/th\u003e\n              \u003ctd\u003e5,000 ppm instant alert, 5000 ppm 8‑h TWA, 1.5% STEL average, 3.0% STEL\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n              \u003ctd\u003eCO2 Mk9 detector\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n              \u003ctd\u003e1 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibco2mk9-block\"\u003e\n      \u003ch2\u003eCompatibility and use cases\u003c\/h2\u003e\n      \u003cp\u003eThis sensor can be used as a standalone unit, connected to a LogiCO2 central unit, or within a computerized supervision system. It also supports connection of horns\/beacons or other external boxes to add functionality.\u003c\/p\u003e\n      \u003cp\u003eIt is suitable for bars, pubs, technical rooms, wineries, breweries, soft drink plants and other spaces where CO2 may accumulate in the event of a leak.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibco2mk9-block\"\u003e\n      \u003ch2\u003eInstallation and considerations before buying\u003c\/h2\u003e\n      \u003cul class=\"ibco2mk9-bullets\"\u003e\n        \u003cli\u003eMk9 and Mk90 CO2 sensors must be installed at a maximum of 30 cm from the floor.\u003c\/li\u003e\n        \u003cli\u003eThe maximum distance to the distribution or leak point is 5 m.\u003c\/li\u003e\n        \u003cli\u003eEach sensor covers a maximum of 78 m².\u003c\/li\u003e\n        \u003cli\u003eIf the room has only mechanical ventilation, the manual states that it must have a sensor.\u003c\/li\u003e\n        \u003cli\u003eIt is advisable to install it in an area where it is less exposed to impacts or mechanical damage.\u003c\/li\u003e\n        \u003cli\u003eBefore purchasing, confirm whether you need only the sensor or also a central unit, beacon, transformer or signaling accessories.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibco2mk9-block\"\u003e\n      \u003ch2\u003eRecommended maintenance and use\u003c\/h2\u003e\n      \u003cp\u003eSince this is a safety product, LogiCO2 recommends carrying out a functional check at least once a year.\u003c\/p\u003e\n      \u003cp\u003eAfter a replacement or expansion, it’s advisable to check the display reading, communication with the control unit if present, and the response of the system’s audible and visual alarms.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibco2mk9-faq\"\u003e\n      \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIs this product an O2 add-on kit?\u003c\/summary\u003e\n        \u003cp\u003eNo. The item corresponds to the CO2 Sensor Mk9, that is, a CO2 sensor.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eCan it operate without a central unit?\u003c\/summary\u003e\n        \u003cp\u003eThe official page states that it can be used as a standalone unit, connected to a central unit or within a larger computerized system.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat alarm levels does it come preset with?\u003c\/summary\u003e\n        \u003cp\u003e5,000 ppm instant alert, 5,000 ppm 8 h TWA, 1.5% average STEL and 3.0% STEL.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhere should it be installed?\u003c\/summary\u003e\n        \u003cp\u003eAt a maximum height of 30 cm from the floor and a maximum distance of 5 m from the CO2 distribution point.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWhat area does one sensor cover?\u003c\/summary\u003e\n        \u003cp\u003eUp to 78 m² according to the Mk9\/Mk90 system manual.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eDoes it require maintenance?\u003c\/summary\u003e\n        \u003cp\u003eYes. The manufacturer recommends a functional check at least once a year.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibco2mk9-downloads\"\u003e\n      \u003ch2\u003eDownloadable\u003c\/h2\u003e\n      \u003cdiv class=\"ibco2mk9-download-grid\"\u003e\n        \u003ca class=\"ibco2mk9-btn\" href=\"https:\/\/www.logico2.com\/products\/co2-sensor-mk9\/\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOfficial Mk9 CO2 Sensor page\u003c\/a\u003e\n        \u003ca class=\"ibco2mk9-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMk9 \/ Mk90 manual in Spanish\u003c\/a\u003e\n        \u003ca class=\"ibco2mk9-btn\" href=\"https:\/\/youtu.be\/1trr3C-eVzs?si=upt3ADfj6txECFaj\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMk9 \/ Mk90 video tutorial\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibco2mk9-related\"\u003e\n      \u003ch2\u003eYou may also be interested in\u003c\/h2\u003e\n      \u003cdiv class=\"ibco2mk9-related-grid\"\u003e\n        \u003ca class=\"ibco2mk9-btn\" href=\"\/en-br\/collections\/logico2-detectores-co2-seguridad-industrial-horeca\"\u003eLogiCO2 products\u003c\/a\u003e\n        \u003ca class=\"ibco2mk9-btn\" href=\"\/en-br\/pages\/servicio-tecnico\"\u003eTechnical advice and installation\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57365631140188,"sku":"LG020","price":1711.23,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/mk9-co2sensor-logico2.webp?v=1776208205","url":"https:\/\/installbeer.com\/en-br\/products\/logico2-co2-sensor-mk9","provider":"Install Beer","version":"1.0","type":"link"}