{"product_id":"conjunto-detector-o2-logico2-mk9-central-alarma","title":"O2-Sensor-Set LogiCO2 Mk9 mit Zentraleinheit und Alarm","description":"\u003csection class=\"iblgo2-product iblgo2-2057\" data-brand=\"LogiCO2\" data-model=\"O2 Mk9 Detector Base SET\"\u003e\n  \u003cstyle\u003e\n    .iblgo2-product{\n      --ib-max:1120px;\n      --ib-text:#1f2328;\n      --ib-muted:#5b6573;\n      --ib-line:#e6e8eb;\n      --ib-soft:#f7f8fa;\n      --ib-soft2:#f2f4f6;\n      --ib-accent:#111111;\n      --ib-radius:18px;\n      --ib-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ib-content-size:16px;\n      --ib-content-lh:1.68;\n      --ib-h2-size:28px;\n      --ib-h3-size:20px;\n      color:var(--ib-text);\n      font-size:var(--ib-content-size);\n      line-height:var(--ib-content-lh);\n    }\n    .iblgo2-product *{box-sizing:border-box}\n    .iblgo2-wrap{max-width:var(--ib-max);margin:0 auto;padding:4px 0 36px}\n    .iblgo2-hero,.iblgo2-block,.iblgo2-specs,.iblgo2-faq,.iblgo2-downloads,.iblgo2-related{\n      background:#fff;border:1px solid var(--ib-line);border-radius:var(--ib-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ib-shadow)\n    }\n    .iblgo2-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ib-line);\n      border-radius:999px;background:var(--ib-soft);color:var(--ib-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblgo2-product h2{\n      font-size:var(--ib-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ib-accent)\n    }\n    .iblgo2-product h3{\n      font-size:var(--ib-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ib-accent)\n    }\n    .iblgo2-product p{margin:0 0 14px;font-size:var(--ib-content-size);line-height:var(--ib-content-lh)}\n    .iblgo2-product p:last-child{margin-bottom:0}\n    .iblgo2-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ib-soft);border:1px solid var(--ib-line)\n    }\n    .iblgo2-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblgo2-card{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:var(--ib-soft)\n    }\n    .iblgo2-card strong{display:block;margin-bottom:6px;color:var(--ib-accent)}\n    .iblgo2-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ib-accent);\n      background:var(--ib-soft2);border-radius:12px\n    }\n    .iblgo2-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblgo2-list-grid li{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:#fff\n    }\n    .iblgo2-list-grid li strong{display:block;margin-bottom:6px}\n    .iblgo2-bullets{margin:0;padding-left:18px}\n    .iblgo2-bullets li{margin:0 0 10px}\n    .iblgo2-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblgo2-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ib-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblgo2-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ib-accent)\n    }\n    .iblgo2-table thead th{\n      background:var(--ib-soft2);color:var(--ib-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);font-size:15px\n    }\n    .iblgo2-table tbody th,.iblgo2-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblgo2-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ib-accent)}\n    .iblgo2-table tbody tr:last-child th,.iblgo2-table tbody tr:last-child td{border-bottom:none}\n    .iblgo2-download-grid,.iblgo2-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblgo2-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ib-accent);text-decoration:none;color:var(--ib-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblgo2-btn:hover{transform:translateY(-1px);box-shadow:var(--ib-shadow)}\n    .iblgo2-faq details{\n      border:1px solid var(--ib-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblgo2-faq details:last-child{margin-bottom:0}\n    .iblgo2-faq summary{cursor:pointer;font-weight:700;color:var(--ib-accent)}\n    .iblgo2-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblgo2-cards,.iblgo2-list-grid,.iblgo2-download-grid,.iblgo2-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblgo2-product{\n        --ib-content-size:15px;\n        --ib-h2-size:23px;\n        --ib-h3-size:18px;\n      }\n      .iblgo2-hero,.iblgo2-block,.iblgo2-specs,.iblgo2-faq,.iblgo2-downloads,.iblgo2-related{\n        padding:18px;border-radius:16px\n      }\n      .iblgo2-table{min-width:100%;border:0}\n      .iblgo2-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblgo2-table,.iblgo2-table tbody,.iblgo2-table tr,.iblgo2-table th,.iblgo2-table td{\n        display:block;width:100%\n      }\n      .iblgo2-table tr{\n        border:1px solid var(--ib-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblgo2-table tbody th{\n        background:var(--ib-soft2);border-bottom:1px solid var(--ib-line)\n      }\n      .iblgo2-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblgo2-wrap\"\u003e\n    \u003cdiv class=\"iblgo2-hero\"\u003e\n      \u003cdiv class=\"iblgo2-kicker\"\u003eO2-Sicherheit · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eO2-Detektor LogiCO2 Mk9 zur Überwachung unsicherer Sauerstoffwerte\u003c\/h2\u003e\n      \u003cp class=\"iblgo2-snippet\"\u003e\u003cstrong\u003eDas LogiCO2 Mk9 O2‑Detektor‑Set integriert optischen Sensor, Zentraleinheit und Sirene\/Blitzleuchte, um unsichere Sauerstoffwerte in geschlossenen Räumen mit Stickstoff oder anderen erstickenden Gasen zu erkennen und optisch wie akustisch zu warnen.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eWas dieses Produkt bietet\u003c\/h2\u003e\n      \u003cp\u003eDieses System ist dafür ausgelegt, Bereiche zu überwachen, in denen der Sauerstoffgehalt unter einen sicheren Schwellenwert fallen kann. Es eignet sich insbesondere für Technikräume, Kühl- und Lagerkammern, Bereiche mit Stickstoff, Stickstoffgeneratoren, Stickstofftanks sowie Zonen mit stickstoffhaltigen Gasgemischen.\u003c\/p\u003e\n      \u003cp\u003eIm Vergleich zu Einzelgeräten umfasst dieses Set bereits O2-Sensor Mk9, Zentraleinheit Mk9, stroboskopische Sirene\/Blitzleuchte, Netzteil, Steckverbinder, Verkabelung und Beschilderung. Dies erleichtert eine geordnete Erstinstallation und eine zentrale Systemüberwachung.\u003c\/p\u003e\n      \u003cp\u003eDer Sensor arbeitet optisch, verfügt über Temperatur- und Druckkompensation, profitiert von einer automatischen Selbstkalibrierung und zeigt die aktuelle O2-Konzentration sowie die Betriebsstunden auf seinem hintergrundbeleuchteten Display an.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eSchlüsseldaten\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-cards\"\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          2057\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG008\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eBasiskonfiguration\u003c\/strong\u003e\n          1 Sensor + 1 Zentraleinheit + 1 Sirene\/Blitzleuchte\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eStandardalarm\u003c\/strong\u003e\n          \u003c19,5 % O2\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eKommunikation\u003c\/strong\u003e\n          RS485 Modbus\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgo2-card\"\u003e\n          \u003cstrong\u003eSystemerweiterung\u003c\/strong\u003e\n          Bis zu 8 Sensoren\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblgo2-note\"\u003e\n        \u003cstrong\u003eWichtig:\u003c\/strong\u003e Dieses Produkt dient nicht zur Detektion von CO2. Es ist zur Überwachung des Sauerstoffgehalts in geschlossenen Räumen mit Risiko einer sauerstoffarmen Atmosphäre ausgelegt, insbesondere dort, wo Stickstoff oder erstickend wirkende Gase eingesetzt werden.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eHaupteigenschaften\u003c\/h2\u003e\n      \u003cul class=\"iblgo2-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eVollständiges O2-Sicherheitssystem\u003c\/strong\u003e Enthält Sensor, Zentrale, Sirene\/Blitzleuchte, Netzteil, Steckverbinder, Schilder und Handbuch.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLanglebiger optischer Sensor\u003c\/strong\u003e LogiCO2 verzichtet auf herkömmliche elektrochemische Zellen und setzt auf optische Detektion mit Selbstkalibrierung.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eZentrale Überwachung\u003c\/strong\u003e Die Zentraleinheit zeigt O2-Werte, Alarme und den Sensor an, der den Vorfall auslöst.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOptischer und akustischer Alarm\u003c\/strong\u003e Zentrale und Sirene\/Blitzleuchte warnen, wenn unsichere Sauerstoffwerte erreicht werden.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBis zu 8 Sensoren\u003c\/strong\u003e Das System kann mit O2-Sensoren Mk9 erweitert werden und unterstützt laut Handbuch auch CO2-Sensoren Mk9 oder Mk90.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHöhenkompensation\u003c\/strong\u003e Der Sensor verfügt über eine Höhenkompensation.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eInstallation in Atemhöhe\u003c\/strong\u003e Ausgelegt für die Montage in 150 bis 180 cm Höhe über dem Boden.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eProfessionelle Innenraumnutzung\u003c\/strong\u003e Ausgerichtet auf geschlossene Räume, in denen ein O2-Mangel die Sicherheit gefährden kann.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-specs\"\u003e\n      \u003ch2\u003eTechnische Daten\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-table-wrap\"\u003e\n        \u003ctable class=\"iblgo2-table\"\u003e\n          \u003ccaption\u003eBestätigte technische Daten des LogiCO2 Mk9 O2-Detektor-Komplettsets\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarke\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModell\u003c\/th\u003e\n              \u003ctd\u003eO2 Mk9 Detector Base SET\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG008\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e2057\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGerätetyp\u003c\/th\u003e\n              \u003ctd\u003eO2-Sicherheitssystem mit Fernsensor, Zentraleinheit und stroboskopischer Sirene\/Blitzleuchte\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eKonfiguration des Sets\u003c\/th\u003e\n              \u003ctd\u003eO2-Sensor Mk9 + Zentraleinheit Mk9 + LED-Sirene\/Blitzleuchte, gelb + Transformator + Verkabelung + Beschilderung\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAnzahl der Sensoren\u003c\/th\u003e\n              \u003ctd\u003e1–8\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eStromversorgung des Systems\u003c\/th\u003e\n              \u003ctd\u003e12–24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensorversorgung\u003c\/th\u003e\n              \u003ctd\u003e24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensorverbrauch\u003c\/th\u003e\n              \u003ctd\u003e\u003c30 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eVerdrahtungsanschlüsse\u003c\/th\u003e\n              \u003ctd\u003eRJ45\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eInterfaz digital\u003c\/th\u003e\n              \u003ctd\u003eRS485-Modbus-Seriellport\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensorausgänge\u003c\/th\u003e\n              \u003ctd\u003e2 Transistorausgänge 24 V DC, min. 1 mA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensoranzeige\u003c\/th\u003e\n              \u003ctd\u003eGráfica 128x64, retroiluminada\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDisplay der Zentraleinheit\u003c\/th\u003e\n              \u003ctd\u003eGráfica 128x64, retroiluminada\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAkustisches Signal des Sensors\u003c\/th\u003e\n              \u003ctd\u003e76 dBA (1 m) max.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAkustisches Signal der Zentraleinheit\u003c\/th\u003e\n              \u003ctd\u003eDas Handbuch beschreibt einen internen akustischen Alarm; die Lautstärke ist im Produktdatenblatt nicht angegeben.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFunktionsprinzip\u003c\/th\u003e\n              \u003ctd\u003eFB‑optisch\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMessbereich O2\u003c\/th\u003e\n              \u003ctd\u003e0–100 Vol.-%\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eO2-Genauigkeit\u003c\/th\u003e\n              \u003ctd\u003e\u003c2 % v. E.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eStandardalarm\u003c\/th\u003e\n              \u003ctd\u003e\u003c19,5 % O2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAjuste adicional\u003c\/th\u003e\n              \u003ctd\u003eCompensación de altitud\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUmgebungstemperatur des Sensors\u003c\/th\u003e\n              \u003ctd\u003eVon -20 bis +40 °C. Nur für den Einsatz in Innenräumen.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDimensiones del sensor\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensorschutz\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza tensión nominal\u003c\/th\u003e\n              \u003ctd\u003e18-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eStromaufnahme Sirene\/Blitzleuchte (mittlerer Wert)\u003c\/th\u003e\n              \u003ctd\u003e120 mA bei 24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSchalldruckpegel Sirene\/Blitzleuchte\u003c\/th\u003e\n              \u003ctd\u003e110 dB \/ 1 m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirene\/Blitzleuchte Blitzintensität\u003c\/th\u003e\n              \u003ctd\u003e115 cd\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBlitzfrequenz Sirene\/Blitzleuchte\u003c\/th\u003e\n              \u003ctd\u003e65\/min\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSignalhorn\/Blitzleuchte Umgebungstemperatur\u003c\/th\u003e\n              \u003ctd\u003eVon -5 bis +50 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza dimensiones\u003c\/th\u003e\n              \u003ctd\u003e134 x 115 x 61 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirene\/Blitzleuchte Schutz\u003c\/th\u003e\n              \u003ctd\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eKapazität der Zentraleinheit\u003c\/th\u003e\n              \u003ctd\u003eBis zu 8 Sensoren; zeigt O2-Werte und den Sensor an, der den Alarm auslöst\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAnzeigen der Zentraleinheit\u003c\/th\u003e\n              \u003ctd\u003eGrüne LED Betrieb, rote LED Alarm, gelbe LED Störung, Taste für Stummschaltung\/Reset\/Test\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLieferumfang\u003c\/th\u003e\n              \u003ctd\u003eZentraleinheit Mk9, rotes Kabel 5 m, O2-Sensor Mk9, rotes Kabel 10 m, blaues Kabel 5 m, Signalhorn\/Blitzleuchte mit gelber LED und 1 m Kabel, RJ45-Abzweiger 1-1, RJ45-Abzweiger 1-2, 1-A-Transformator, Stecker UL\/CE\/AU\/UK, Steckerverriegelung, Beutel mit 6 Schrauben und Dübeln, Schild O2-Sicherheitssystem Mk9, Schild Signalhorn\/Blitzleuchte Mk9 und Installationshandbuch O2 Mk9\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGTIN\/EAN\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSA\/HS-Code\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGewicht\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eKompatibilität und Anwendungsfälle\u003c\/h2\u003e\n      \u003cp\u003eDieses System wird in geschlossenen Räumen eingesetzt, in denen das Risiko einer unsicheren Sauerstoffkonzentration besteht. Das Handbuch selbst sieht den Sensor an Stickstoffverteilpunkten, Stickstoffgeneratoren, Stickstofftanks und Bereichen mit mit Stickstoff gemischtem Gas vor.\u003c\/p\u003e\n      \u003cp\u003eEs kann auch verwendet werden, wenn das erstickend wirkende Gas außerhalb des Gebäudes gelagert wird, aber über Rohrleitungen ins Gebäude gelangt, sofern der überwachte Bereich dort liegt, wo tatsächlich ein Risiko für Personen besteht.\u003c\/p\u003e\n      \u003cp\u003eDas System kann mit bis zu acht O2‑Sensoren Mk9 erweitert werden, und laut Handbuch kann die Zentraleinheit innerhalb der LogiCO2‑Architektur ebenfalls mit CO2‑Sensoren Mk9 und Mk90 zusammenarbeiten.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eInstallation und Hinweise vor dem Kauf\u003c\/h2\u003e\n      \u003cul class=\"iblgo2-bullets\"\u003e\n        \u003cli\u003eDer O2-Sensor sollte in Atemhöhe, zwischen 150 und 180 cm über dem Boden, montiert werden.\u003c\/li\u003e\n        \u003cli\u003eDie Sirene\/Blitzleuchte sollte oberhalb des Sensors in etwa 2–2,4 m Höhe angebracht und von jedem Zugang des überwachten Bereichs aus sichtbar sein.\u003c\/li\u003e\n        \u003cli\u003eEs wird empfohlen, eine zweite Sirene\/Blitzleuchte außerhalb des überwachten Bereichs zu installieren, vorzugsweise über der Zugangs- oder den Zugangstüren.\u003c\/li\u003e\n        \u003cli\u003eDie Zentraleinheit muss außerhalb des überwachten Bereichs oder Raums an einer gut sichtbaren und zugänglichen Stelle installiert werden.\u003c\/li\u003e\n        \u003cli\u003eWenn der Raum ausschließlich über eine mechanische Lüftung verfügt, schreibt das Handbuch vor, dass dort ein Sensor installiert sein muss.\u003c\/li\u003e\n        \u003cli\u003eWird im selben Bereich ein Stickstoffgenerator eingesetzt, muss der entstehende Sauerstoffüberschuss abgeführt werden; im Handbuch ist angegeben, dass der Sensor in diesem Bereich nicht verwendet werden darf, wenn dieser Sauerstoff nicht abgeführt wird.\u003c\/li\u003e\n        \u003cli\u003eDas System funktioniert nicht, wenn es vom Stromnetz getrennt wird. Daher müssen die Spannungsversorgung und deren mechanische Verriegelung vor der Inbetriebnahme überprüft werden.\u003c\/li\u003e\n        \u003cli\u003eAls Sicherheitsgerät dürfen Installation und Wartung ausschließlich von Fachpersonal durchgeführt werden.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-block\"\u003e\n      \u003ch2\u003eEmpfohlene Wartung und Nutzung\u003c\/h2\u003e\n      \u003cp\u003eDer O2-Sensor LogiCO2 verfügt über eine standardmäßig aktivierte automatische Selbstkalibrierung und sollte unter normalen Bedingungen keine manuelle Kalibrierung erfordern, sofern er dauerhaft eingeschaltet bleibt. Der Hersteller weist jedoch darauf hin, dass beim ersten Inbetriebnehmen eine manuelle Kalibrierung erforderlich ist.\u003c\/p\u003e\n      \u003cp\u003eDa es sich um ein Sicherheitsprodukt handelt, wird außerdem empfohlen, mindestens einmal jährlich eine Funktionsprüfung durchzuführen. Die Reinigung sollte mit Wasser und einem angefeuchteten Tuch erfolgen; Sensor und Gehäuse der Zentraleinheit dürfen von unbefugtem Personal nicht geöffnet werden.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-faq\"\u003e\n      \u003ch2\u003eHäufig gestellte Fragen\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eErkennt dieses System CO2?\u003c\/summary\u003e\n        \u003cp\u003eNein. Dieses Produkt ist zur Detektion unsicherer Sauerstoffwerte in geschlossenen Räumen ausgelegt.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWas genau ist im Set 2057 enthalten?\u003c\/summary\u003e\n        \u003cp\u003eEnthält O2-Sensor Mk9, Zentraleinheit Mk9, stroboskopische Sirene\/Blitzleuchte, Transformator, Verkabelung, RJ45-Steckverbinder, Beschilderung und Installationshandbuch.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWo muss der O2-Sensor installiert werden?\u003c\/summary\u003e\n        \u003cp\u003eEr muss in Atemhöhe, zwischen 150 und 180 cm über dem Boden, in dem Bereich installiert werden, in dem tatsächlich ein Risiko einer unsicheren Atmosphäre besteht.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWo werden Sirene\/Blitzleuchte und Zentraleinheit installiert?\u003c\/summary\u003e\n        \u003cp\u003eDie Sirene\/Blitzleuchte sollte oberhalb des Sensors in etwa 2–2,4 m Höhe angebracht werden. Die Zentraleinheit ist außerhalb des überwachten Bereichs an einem gut sichtbaren und zugänglichen Ort zu montieren.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWie hoch ist das Standard-Alarmniveau?\u003c\/summary\u003e\n        \u003cp\u003eDer Hersteller gibt einen Standard-Alarmwert von 19,5 % O2 an.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Necesita mantenimiento periódico?\u003c\/summary\u003e\n        \u003cp\u003eJa. Obwohl eine automatische Selbstkalibrierung vorhanden ist, wird mindestens einmal jährlich eine Funktionsprüfung sowie eine anfängliche manuelle Kalibrierung bei der Inbetriebnahme des Systems empfohlen.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-downloads\"\u003e\n      \u003ch2\u003eDownloadbereich\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-download-grid\"\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/O2_Mk9_Detector_BaseSET_2057_es_db_LogiCO2.pdf?v=1775037461\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnisches Datenblatt LogiCO2 2057\u003c\/a\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/o2ss_mk9_2057_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHandbuch O2 Mk9\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgo2-related\"\u003e\n      \u003ch2\u003eTambién puede interesarte\u003c\/h2\u003e\n      \u003cdiv class=\"iblgo2-related-grid\"\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"\/de\/collections\/alarmas-detectores-logico2\"\u003eLogiCO2-Alarmgeräte und -Detektoren\u003c\/a\u003e\n        \u003ca class=\"iblgo2-btn\" href=\"\/de\/pages\/servicio-tecnico\"\u003eAsesoramiento e instalación técnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57238900572508,"sku":"LG008","price":1090.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/o2-mk9detector-set-logic2.webp?v=1775037730","url":"https:\/\/installbeer.com\/de\/products\/satz-detektor-o2-logico2-mk9-zentrale-alarm","provider":"Install Beer","version":"1.0","type":"link"}