{"product_id":"modulo-sensor-o2-logico2-mk9","title":"Zusatzkit O2‑Sensor LogiCO2 Mk9","description":"\u003csection class=\"ibo2m-product ibo2m-1142\" data-brand=\"LogiCO2\" data-model=\"O2 Sensor Mk9\"\u003e\n  \u003cstyle\u003e\n    .ibo2m-product{\n      --ibo2m-max:1120px;\n      --ibo2m-text:#1f2328;\n      --ibo2m-muted:#5b6573;\n      --ibo2m-line:#e6e8eb;\n      --ibo2m-soft:#f7f8fa;\n      --ibo2m-soft2:#f2f4f6;\n      --ibo2m-accent:#111111;\n      --ibo2m-radius:18px;\n      --ibo2m-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ibo2m-content-size:16px;\n      --ibo2m-content-lh:1.68;\n      --ibo2m-h2-size:28px;\n      --ibo2m-h3-size:20px;\n      color:var(--ibo2m-text);\n      font-size:var(--ibo2m-content-size);\n      line-height:var(--ibo2m-content-lh);\n    }\n    .ibo2m-product *{box-sizing:border-box}\n    .ibo2m-wrap{max-width:var(--ibo2m-max);margin:0 auto;padding:4px 0 36px}\n    .ibo2m-hero,.ibo2m-block,.ibo2m-specs,.ibo2m-faq,.ibo2m-downloads,.ibo2m-related{\n      background:#fff;border:1px solid var(--ibo2m-line);border-radius:var(--ibo2m-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ibo2m-shadow)\n    }\n    .ibo2m-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ibo2m-line);\n      border-radius:999px;background:var(--ibo2m-soft);color:var(--ibo2m-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .ibo2m-product h2{\n      font-size:var(--ibo2m-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ibo2m-accent)\n    }\n    .ibo2m-product h3{\n      font-size:var(--ibo2m-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ibo2m-accent)\n    }\n    .ibo2m-product p{\n      margin:0 0 14px;\n      font-size:var(--ibo2m-content-size);\n      line-height:var(--ibo2m-content-lh)\n    }\n    .ibo2m-product p:last-child{margin-bottom:0}\n    .ibo2m-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ibo2m-soft);border:1px solid var(--ibo2m-line)\n    }\n    .ibo2m-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .ibo2m-card{\n      padding:16px;border:1px solid var(--ibo2m-line);border-radius:16px;background:var(--ibo2m-soft)\n    }\n    .ibo2m-card strong{display:block;margin-bottom:6px;color:var(--ibo2m-accent)}\n    .ibo2m-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ibo2m-accent);\n      background:var(--ibo2m-soft2);border-radius:12px\n    }\n    .ibo2m-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .ibo2m-list-grid li{\n      padding:16px;border:1px solid var(--ibo2m-line);border-radius:16px;background:#fff\n    }\n    .ibo2m-list-grid li strong{display:block;margin-bottom:6px}\n    .ibo2m-bullets{margin:0;padding-left:18px}\n    .ibo2m-bullets li{margin:0 0 10px}\n    .ibo2m-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .ibo2m-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ibo2m-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .ibo2m-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ibo2m-accent)\n    }\n    .ibo2m-table thead th{\n      background:var(--ibo2m-soft2);color:var(--ibo2m-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ibo2m-line);font-size:15px\n    }\n    .ibo2m-table tbody th,.ibo2m-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ibo2m-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .ibo2m-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ibo2m-accent)}\n    .ibo2m-table tbody tr:last-child th,.ibo2m-table tbody tr:last-child td{border-bottom:none}\n    .ibo2m-download-grid,.ibo2m-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .ibo2m-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ibo2m-accent);text-decoration:none;color:var(--ibo2m-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .ibo2m-btn:hover{transform:translateY(-1px);box-shadow:var(--ibo2m-shadow)}\n    .ibo2m-faq details{\n      border:1px solid var(--ibo2m-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .ibo2m-faq details:last-child{margin-bottom:0}\n    .ibo2m-faq summary{cursor:pointer;font-weight:700;color:var(--ibo2m-accent)}\n    .ibo2m-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .ibo2m-cards,.ibo2m-list-grid,.ibo2m-download-grid,.ibo2m-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .ibo2m-product{\n        --ibo2m-content-size:15px;\n        --ibo2m-h2-size:23px;\n        --ibo2m-h3-size:18px;\n      }\n      .ibo2m-hero,.ibo2m-block,.ibo2m-specs,.ibo2m-faq,.ibo2m-downloads,.ibo2m-related{\n        padding:18px;border-radius:16px\n      }\n      .ibo2m-table{min-width:100%;border:0}\n      .ibo2m-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .ibo2m-table,.ibo2m-table tbody,.ibo2m-table tr,.ibo2m-table th,.ibo2m-table td{\n        display:block;width:100%\n      }\n      .ibo2m-table tr{\n        border:1px solid var(--ibo2m-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .ibo2m-table tbody th{\n        background:var(--ibo2m-soft2);border-bottom:1px solid var(--ibo2m-line)\n      }\n      .ibo2m-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"ibo2m-wrap\"\u003e\n    \u003cdiv class=\"ibo2m-hero\"\u003e\n      \u003cdiv class=\"ibo2m-kicker\"\u003eSauerstoffsensor · LogiCO2\u003c\/div\u003e\n      \u003ch2\u003eLogiCO2 O2-Sensor Mk9 zur Erweiterung oder zum Austausch eines Messpunkts\u003c\/h2\u003e\n      \u003cp class=\"ibo2m-snippet\"\u003e\u003cstrong\u003eDas O2‑Sensormodul LogiCO2 Mk9 ist ein optischer Sauerstoffsensor für Systeme mit Mk9‑Zentrale. Es misst die Umgebungs‑O2‑Konzentration, zeigt den Wert im Display an und löst Alarm aus, wenn der Pegel unter einen sicheren Schwellenwert fällt.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eWas dieses Produkt bietet\u003c\/h2\u003e\n      \u003cp\u003eDieses Produkt eignet sich als Ersatzteil oder Erweiterung innerhalb eines bereits bestehenden LogiCO2‑Systems. Es ist kein komplettes Kit mit Zentrale, Sirene oder Netzteil, sondern das Sauerstoff‑Sensormodul.\u003c\/p\u003e\n      \u003cp\u003eSein technischer Wert liegt in der optischen Sauerstoffmessung mit integriertem Temperatur- und Druckabgleich, einem geringen Verbrauch und einer langen Lebensdauer. Der Hersteller gibt außerdem an, dass das Gerät ab Werk kalibriert ist.\u003c\/p\u003e\n      \u003cp\u003eEs ist eine sinnvolle Lösung für Installationen, in denen Atmosphären mit niedrigem Sauerstoffrisiko überwacht und die Messung in das LogiCO2‑Mk9‑Ökosystem integriert werden soll.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eSchlüsseldaten\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2m-cards\"\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eHerstellerartikel\u003c\/strong\u003e\n          1142\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG012\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eTyp\u003c\/strong\u003e\n          O2-Sensor für System mit Mk9-Zentrale\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eMessbereich\u003c\/strong\u003e\n          0–25 % O2\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eOptischer Alarm\u003c\/strong\u003e\n          Rot bei Alarm \u003c19,5 % O2\n        \u003c\/div\u003e\n        \u003cdiv class=\"ibo2m-card\"\u003e\n          \u003cstrong\u003eVerkaufsformat\u003c\/strong\u003e\n          Ersatzteil ohne Kabel\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"ibo2m-note\"\u003e\n        \u003cstrong\u003eWichtig:\u003c\/strong\u003e Dieser Artikel ist als Ersatzteil ohne Kabel dokumentiert. Vor dem Kauf solltest du bestätigen, dass bereits eine passende Verkabelung und eine kompatible LogiCO2‑Mk9‑Architektur vorhanden sind.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eHaupteigenschaften\u003c\/h2\u003e\n      \u003cul class=\"ibo2m-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOptischer O2-Sensor\u003c\/strong\u003e Nutzt das FB-optical-Prinzip zur Messung der Umgebungssauerstoffkonzentration.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIntegrierte Kompensation\u003c\/strong\u003e Mit integrierter Temperatur‑ und Druckkompensation.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAb Werk kalibriert\u003c\/strong\u003e Der Hersteller liefert das Gerät werkseitig kalibriert aus.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eKompatibel mit Zentrale Mk9\u003c\/strong\u003e Kommuniziert per Modbus RTU mit der LogiCO2‑Zentraleinheit Mk9.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eKompatibel mit CO2‑Sensoren\u003c\/strong\u003e Kann zusammen mit den verschiedenen LogiCO2‑CO2‑Sensoren innerhalb desselben Systems betrieben werden.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHintergrundbeleuchtetes Display\u003c\/strong\u003e Zeigt aktuelle O2‑Konzentration und Betriebsstunden an.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eKlare lokale Signalisierung\u003c\/strong\u003e Betriebs‑, Störungs‑ und Alarm‑LEDs sowie akustische Warnung bei Störung oder Alarm.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eKompaktes Format\u003c\/strong\u003e Platzsparende Abmessungen für die Integration in technische Installationen.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-specs\"\u003e\n      \u003ch2\u003eTechnische Daten\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2m-table-wrap\"\u003e\n        \u003ctable class=\"ibo2m-table\"\u003e\n          \u003ccaption\u003eBestätigte technische Spezifikationen des LogiCO2 Mk9 O2-Sensormoduls\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eBestätigte Angabe\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarke\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModell\u003c\/th\u003e\n              \u003ctd\u003eO2‑Sensor Mk9\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG012\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ Herstellernummer\u003c\/th\u003e\n              \u003ctd\u003e1142\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGerätetyp\u003c\/th\u003e\n              \u003ctd\u003eSauerstoffsensor für LogiCO2‑System Mk9\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLieferform\u003c\/th\u003e\n              \u003ctd\u003eSensor ohne Kabel, als Ersatzteil ausgewiesen\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eStromversorgung\u003c\/th\u003e\n              \u003ctd\u003e24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFunktionsprinzip\u003c\/th\u003e\n              \u003ctd\u003eFB-optisch\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMessbereich\u003c\/th\u003e\n              \u003ctd\u003e0–25 % O2‑Konzentration\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003ePrecisión\u003c\/th\u003e\n              \u003ctd\u003e\u003c2 % FS\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSystemkompatibilität\u003c\/th\u003e\n              \u003ctd\u003eKompatibel mit LogiCO2 Mk9 CO2 Safety System\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eKommunikation\u003c\/th\u003e\n              \u003ctd\u003eModbus RTU mit der LogiCO2‑Zentrale Mk9\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n              \u003ctd\u003eHintergrundbeleuchtet; zeigt aktuelle O2-Konzentration und Betriebsstunden an\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLEDs\u003c\/th\u003e\n              \u003ctd\u003eGrün: Betrieb · Gelb: Störung · Rot: Alarm (\u003c19,5 % O2)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAkustische Warnung\u003c\/th\u003e\n              \u003ctd\u003eBlinkend: Störung · Dauerlicht: Alarm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSchutz gegen Eindringen\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAbmessungen\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eZulassungen\u003c\/th\u003e\n              \u003ctd\u003eUL 61010-1, CAN\/CSA-C22.2 Nr. 61010-1-12, IEC 60529\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n              \u003ctd\u003eKunststoff\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGewicht\u003c\/th\u003e\n              \u003ctd\u003e1 Kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLieferumfang\u003c\/th\u003e\n              \u003ctd\u003eO2-Mk9-Sensor\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eKompatibilität und Anwendungsfälle\u003c\/h2\u003e\n      \u003cp\u003eDieser Sensor ist für den Betrieb mit der LogiCO2-Mk9-Zentrale ausgelegt und kommuniziert per Modbus RTU innerhalb der Sicherheitsanlage.\u003c\/p\u003e\n      \u003cp\u003eDer Hersteller gibt an, dass sie zusammen mit den verschiedenen LogiCO2-CO2-Sensoren verwendet werden kann, was sie in Mischinstallationen nützlich macht, in denen unterschiedliche Gasrisiken innerhalb derselben Architektur überwacht werden.\u003c\/p\u003e\n      \u003cp\u003eEs eignet sich als Ersatz für einen vorhandenen Sensor oder als Erweiterung eines kompatiblen Systems, sofern die Konfiguration der Anlage und die zugehörige Verkabelung eingehalten werden.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eInstallation und Hinweise vor dem Kauf\u003c\/h2\u003e\n      \u003cul class=\"ibo2m-bullets\"\u003e\n        \u003cli\u003eStelle vor dem Kauf sicher, dass deine Installation über eine kompatible LogiCO2‑Zentrale Mk9 verfügt.\u003c\/li\u003e\n        \u003cli\u003ePrüfe, ob du nur den Sensor oder auch eine Verkabelung benötigst, da das Datenblatt ihn als Ersatzteil ohne Kabel definiert.\u003c\/li\u003e\n        \u003cli\u003eÜberprüfe die Referenz des zu ersetzenden Sensors, um Fehler bei Wartung oder Erweiterung zu vermeiden.\u003c\/li\u003e\n        \u003cli\u003eWenn Ihr System CO2- und O2-Sensoren kombiniert, prüfen Sie vor einer Erweiterung die Gesamtarchitektur.\u003c\/li\u003e\n        \u003cli\u003eAl ser un componente de seguridad, la instalación y comprobación funcional deben realizarse con criterio técnico.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-block\"\u003e\n      \u003ch2\u003eEmpfohlene Wartung und Nutzung\u003c\/h2\u003e\n      \u003cp\u003eDa es sich um einen Sicherheitssensor handelt, sollten sein Funktionszustand, die Anzeige, die LED‑Signalisation sowie die akustische Störungs‑\/Alarmmeldung regelmäßig überprüft werden.\u003c\/p\u003e\n      \u003cp\u003eNach jedem Austausch sollte die korrekte Kommunikation mit der Mk9-Zentrale überprüft und kontrolliert werden, ob Messwertanzeige und lokale Signalisierung ordnungsgemäß reagieren.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-faq\"\u003e\n      \u003ch2\u003eHäufig gestellte Fragen\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIst dieses Produkt ein vollständiges Detektionssystem?\u003c\/summary\u003e\n        \u003cp\u003eNein. Es handelt sich nur um das O2‑Sensormodul, eine Zentrale oder ein komplettes Alarmkit ist nicht enthalten.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003e¿Incluye cable?\u003c\/summary\u003e\n        \u003cp\u003eIm Datenblatt ist es als Ersatzteil ohne Kabel dokumentiert.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eMit welcher Zentrale ist er kompatibel?\u003c\/summary\u003e\n        \u003cp\u003eEr ist mit der Zentraleinheit LogiCO2 Mk9 kompatibel und kommuniziert über Modbus RTU.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eKann er zusammen mit CO2‑Sensoren betrieben werden?\u003c\/summary\u003e\n        \u003cp\u003eJa. Der Hersteller gibt an, dass es zusammen mit den verschiedenen CO2-Sensoren von LogiCO2 verwendet werden kann.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWelchen O2-Messbereich deckt es ab?\u003c\/summary\u003e\n        \u003cp\u003eEs misst Sauerstoffkonzentrationen von 0 bis 25 %.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eAb wann schaltet die optische Anzeige auf Rot?\u003c\/summary\u003e\n        \u003cp\u003eWenn die Konzentration unter 19,5 % O2 fällt.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-downloads\"\u003e\n      \u003ch2\u003eDownloadbereich\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2m-download-grid\"\u003e\n        \u003ca class=\"ibo2m-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/O2_Mk9_Sensor_1142_en_db_LogiCO2.pdf?v=1776184711\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnisches Datenblatt O2 Mk9 Sensor\u003c\/a\u003e\n        \u003ca class=\"ibo2m-btn\" href=\"https:\/\/www.logico2.com\/products\/o2-sensor-mk9\/\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOffizielle Produktseite\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"ibo2m-related\"\u003e\n      \u003ch2\u003eDas könnte Sie auch interessieren\u003c\/h2\u003e\n      \u003cdiv class=\"ibo2m-related-grid\"\u003e\n        \u003ca class=\"ibo2m-btn\" href=\"\/de\/collections\/logico2-detectores-co2-seguridad-industrial-horeca\"\u003eLogiCO2-Produkte\u003c\/a\u003e\n        \u003ca class=\"ibo2m-btn\" href=\"\/de\/pages\/servicio-tecnico\"\u003eTechnische Beratung und Installation\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57365628518748,"sku":"LG012","price":790.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/mk9-o2sensor-cab-logico2.webp?v=1776207536","url":"https:\/\/installbeer.com\/de\/products\/modul-o2-sensor-logico2-mk9","provider":"Install Beer","version":"1.0","type":"link"}