{"product_id":"conjunto-sensores-co2-camaras-frigorificas-logico2-mk90","title":"CO2-Sensorset für Kühlräume LogiCO2 Mk90","description":"\u003csection class=\"iblgcr-product iblgcr-3349\" data-brand=\"LogiCO2\" data-model=\"CO2 Cold room Mk90 Detector Base SET\"\u003e\n  \u003cstyle\u003e\n    .iblgcr-product{\n      --ib-max:1120px;\n      --ib-text:#1f2328;\n      --ib-muted:#5b6573;\n      --ib-line:#e6e8eb;\n      --ib-soft:#f7f8fa;\n      --ib-soft2:#f2f4f6;\n      --ib-accent:#111111;\n      --ib-radius:18px;\n      --ib-shadow:0 12px 30px rgba(0,0,0,.05);\n      --ib-content-size:16px;\n      --ib-content-lh:1.68;\n      --ib-h2-size:28px;\n      --ib-h3-size:20px;\n      color:var(--ib-text);\n      font-size:var(--ib-content-size);\n      line-height:var(--ib-content-lh);\n    }\n    .iblgcr-product *{box-sizing:border-box}\n    .iblgcr-wrap{max-width:var(--ib-max);margin:0 auto;padding:4px 0 36px}\n    .iblgcr-hero,.iblgcr-block,.iblgcr-specs,.iblgcr-faq,.iblgcr-downloads,.iblgcr-related{\n      background:#fff;border:1px solid var(--ib-line);border-radius:var(--ib-radius);\n      padding:24px;margin:0 0 18px;box-shadow:var(--ib-shadow)\n    }\n    .iblgcr-kicker{\n      display:inline-flex;align-items:center;gap:8px;padding:7px 12px;border:1px solid var(--ib-line);\n      border-radius:999px;background:var(--ib-soft);color:var(--ib-muted);font-size:13px;\n      line-height:1.2;font-weight:700;letter-spacing:.02em;text-transform:uppercase;margin:0 0 14px\n    }\n    .iblgcr-product h2{\n      font-size:var(--ib-h2-size);line-height:1.2;letter-spacing:-.02em;margin:0 0 14px;color:var(--ib-accent)\n    }\n    .iblgcr-product h3{\n      font-size:var(--ib-h3-size);line-height:1.28;margin:0 0 10px;color:var(--ib-accent)\n    }\n    .iblgcr-product p{margin:0 0 14px;font-size:var(--ib-content-size);line-height:var(--ib-content-lh)}\n    .iblgcr-product p:last-child{margin-bottom:0}\n    .iblgcr-snippet{\n      margin:0;padding:16px 18px;border-radius:14px;background:var(--ib-soft);border:1px solid var(--ib-line)\n    }\n    .iblgcr-cards{\n      display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:14px;margin-top:16px\n    }\n    .iblgcr-card{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:var(--ib-soft)\n    }\n    .iblgcr-card strong{display:block;margin-bottom:6px;color:var(--ib-accent)}\n    .iblgcr-note{\n      margin-top:16px;padding:14px 16px;border-left:4px solid var(--ib-accent);\n      background:var(--ib-soft2);border-radius:12px\n    }\n    .iblgcr-list-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0;padding:0;list-style:none\n    }\n    .iblgcr-list-grid li{\n      padding:16px;border:1px solid var(--ib-line);border-radius:16px;background:#fff\n    }\n    .iblgcr-list-grid li strong{display:block;margin-bottom:6px}\n    .iblgcr-bullets{margin:0;padding-left:18px}\n    .iblgcr-bullets li{margin:0 0 10px}\n    .iblgcr-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n    .iblgcr-table{\n      width:100%;min-width:760px;border-collapse:collapse;border:1px solid var(--ib-line);\n      border-radius:16px;overflow:hidden;background:#fff\n    }\n    .iblgcr-table caption{\n      caption-side:top;text-align:left;padding:0 0 12px;font-weight:700;color:var(--ib-accent)\n    }\n    .iblgcr-table thead th{\n      background:var(--ib-soft2);color:var(--ib-accent);font-weight:700;text-align:left;\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);font-size:15px\n    }\n    .iblgcr-table tbody th,.iblgcr-table tbody td{\n      padding:14px 16px;border-bottom:1px solid var(--ib-line);vertical-align:top;text-align:left;\n      font-size:15px;line-height:1.55\n    }\n    .iblgcr-table tbody th{width:34%;background:#fcfcfd;font-weight:700;color:var(--ib-accent)}\n    .iblgcr-table tbody tr:last-child th,.iblgcr-table tbody tr:last-child td{border-bottom:none}\n    .iblgcr-download-grid,.iblgcr-related-grid{\n      display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px\n    }\n    .iblgcr-btn{\n      display:flex;align-items:center;justify-content:center;gap:8px;min-height:48px;padding:12px 16px;\n      border-radius:12px;border:1px solid var(--ib-accent);text-decoration:none;color:var(--ib-accent);\n      font-weight:700;background:#fff;transition:transform .15s ease, box-shadow .15s ease;text-align:center\n    }\n    .iblgcr-btn:hover{transform:translateY(-1px);box-shadow:var(--ib-shadow)}\n    .iblgcr-faq details{\n      border:1px solid var(--ib-line);border-radius:14px;padding:14px 16px;background:#fff;margin-bottom:12px\n    }\n    .iblgcr-faq details:last-child{margin-bottom:0}\n    .iblgcr-faq summary{cursor:pointer;font-weight:700;color:var(--ib-accent)}\n    .iblgcr-faq details p{margin:12px 0 0}\n    @media (max-width:900px){\n      .iblgcr-cards,.iblgcr-list-grid,.iblgcr-download-grid,.iblgcr-related-grid{grid-template-columns:1fr}\n    }\n    @media (max-width:740px){\n      .iblgcr-product{\n        --ib-content-size:15px;\n        --ib-h2-size:23px;\n        --ib-h3-size:18px;\n      }\n      .iblgcr-hero,.iblgcr-block,.iblgcr-specs,.iblgcr-faq,.iblgcr-downloads,.iblgcr-related{\n        padding:18px;border-radius:16px\n      }\n      .iblgcr-table{min-width:100%;border:0}\n      .iblgcr-table thead{\n        position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);\n        white-space:nowrap;border:0\n      }\n      .iblgcr-table,.iblgcr-table tbody,.iblgcr-table tr,.iblgcr-table th,.iblgcr-table td{\n        display:block;width:100%\n      }\n      .iblgcr-table tr{\n        border:1px solid var(--ib-line);border-radius:14px;margin-bottom:12px;overflow:hidden\n      }\n      .iblgcr-table tbody th{\n        background:var(--ib-soft2);border-bottom:1px solid var(--ib-line)\n      }\n      .iblgcr-table tbody td{border-bottom:none;padding-top:12px}\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"iblgcr-wrap\"\u003e\n    \u003cdiv class=\"iblgcr-hero\"\u003e\n      \u003cdiv class=\"iblgcr-kicker\"\u003eCO2‑Sicherheit · Kühlräume\u003c\/div\u003e\n      \u003ch2\u003eCO2-Sensor für Kühlräume LogiCO2 mit zuverlässiger Detektion bei Kälte\u003c\/h2\u003e\n      \u003cp class=\"iblgcr-snippet\"\u003e\u003cstrong\u003eDas LogiCO2-Set 3349 ist ein CO2-Detektionssystem für Kühl- und Tiefkühlräume mit Cold-Room-Sensor, Zentraleinheit Mk9 und Sirene\/Blitzleuchte zur Überwachung von Leckagen in kalten Umgebungen, in denen ein herkömmlicher Detektor an Genauigkeit verlieren kann.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eQué aporta este producto\u003c\/h2\u003e\n      \u003cp\u003eDieses Gerät ist für Kühlräume und Tiefkühlanwendungen vorgesehen, in denen sich CO2 durch ein Leck ansammeln kann und ein Standardsensor bei niedriger Temperatur keine ausreichend zuverlässige Reaktion bietet.\u003c\/p\u003e\n      \u003cp\u003eDer eigentliche Vorteil dieses Sets ist, dass es bereits die Systembasis integriert: kältespezifischer Sensor, Zentraleinheit Mk9, Sirene\/Blitzleuchte, Netzteil, Steckverbinder, Beschilderung und Schutzabdeckung. Das reduziert Konfigurationsfehler und vereinfacht eine fachgerechte Installation.\u003c\/p\u003e\n      \u003cp\u003eAußerdem weist der Hersteller darauf hin, dass die Cold-Room-Lösung speziell für Kühl- und Tiefkühlanwendungen ausgelegt ist und dass sich der Sensor vom Standardsensor Mk90 im Temperaturbereich und in einem über DIP-Schalter 1 konfigurierbaren Alarmniveau unterscheidet.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eSchlüsseldaten\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-cards\"\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eArtículo fabricante\u003c\/strong\u003e\n          3349\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eSKU Install Beer\u003c\/strong\u003e\n          LG007\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eHauptanwendung\u003c\/strong\u003e\n          Kühl- und Tiefkühlräume\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eSensor\u003c\/strong\u003e\n          Cold Room CO2 Sensor\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eZentraleinheit enthalten\u003c\/strong\u003e\n          Zentraleinheit Mk9\n        \u003c\/div\u003e\n        \u003cdiv class=\"iblgcr-card\"\u003e\n          \u003cstrong\u003eArbeitstemperatur des Sensors\u003c\/strong\u003e\n          Von -40 °C bis 25 °C\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"iblgcr-note\"\u003e\n        \u003cstrong\u003eWichtig:\u003c\/strong\u003e Dieses Produkt ist auf kalte Umgebungen ausgerichtet. Wenn Ihre Anlage mehrere Gefahrenpunkte oder mehrere Kühlräume hat, sieht die Herstellerdokumentation eine Erweiterung mit zusätzlichen Kits und bis zu zwölf Sensoren an einer Zentraleinheit vor.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eHaupteigenschaften\u003c\/h2\u003e\n      \u003cul class=\"iblgcr-list-grid\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFür echte Kälte ausgelegt\u003c\/strong\u003e Der Hersteller passt das Gerät speziell an Kühl- und Tiefkühlräume an, in denen herkömmliche Detektoren stärkere Abweichungen zeigen können.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eVollständiges Basisset\u003c\/strong\u003e Enthält Cold-Room-Sensor, Zentraleinheit Mk9, Signalhorn\/Blitzleuchte, Netzteil, Verbinder, Verkabelung, Handbuch und Beschilderung.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePräzise CO2-Detektion\u003c\/strong\u003e Ausgelegt für Sicherheit in Umgebungen, in denen ein Leck unbemerkt bleiben kann, wenn der Sensor nicht für niedrige Temperaturen ausgelegt ist.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eProfessionelle Architektur\u003c\/strong\u003e Nutzt RS485-Modbus-Kommunikation, wie sie in technischen Überwachungssystemen üblich ist.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eErweiterbar\u003c\/strong\u003e An eine Zentraleinheit können bis zu zwölf Sensoren angeschlossen werden, und Zusatzkits lassen sich im Plug-and-Play-Modus integrieren.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOptischer und akustischer Alarm\u003c\/strong\u003e Die Stroboskop-Sirene\/Blitzleuchte hilft, sowohl innerhalb als auch außerhalb des überwachten Bereichs zu warnen.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHöhenkompensation\u003c\/strong\u003e Der Sensor kann so eingestellt werden, dass er die Einbauhöhe über dem Meeresspiegel kompensiert.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAutomatische Kalibrierung\u003c\/strong\u003e Führt mehrmals im Jahr eine Selbstkalibrierung durch.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-specs\"\u003e\n      \u003ch2\u003eTechnische Daten\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-table-wrap\"\u003e\n        \u003ctable class=\"iblgcr-table\"\u003e\n          \u003ccaption\u003eBestätigte technische Spezifikationen des LogiCO2 Cold Room Sets 3349\u003c\/caption\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"col\"\u003eParámetro\u003c\/th\u003e\n              \u003cth scope=\"col\"\u003eDato confirmado\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMarke\u003c\/th\u003e\n              \u003ctd\u003eLogiCO2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eModell\u003c\/th\u003e\n              \u003ctd\u003eCO2 Cold room Mk90 Detector Base SET \/ CO2-Sensorset für Kühlräume\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n              \u003ctd\u003eLG007\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eMPN \/ artículo fabricante\u003c\/th\u003e\n              \u003ctd\u003e3349\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGerätetyp\u003c\/th\u003e\n              \u003ctd\u003eBasissystem zur CO2-Detektion für Kühl- und Tiefkühlräume\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAnwendung\u003c\/th\u003e\n              \u003ctd\u003eAnwendungen in Kühl- und Tiefkühlräumen\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eHauptkomponenten des Sets\u003c\/th\u003e\n              \u003ctd\u003eCO2-Sensor für Kühlraum + Zentraleinheit Mk9 + Horn\/Strobe LED amber glass + Power Supply 1A + Protection Cover\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSensorreferenz\u003c\/th\u003e\n              \u003ctd\u003e1153\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eReferenz der Zentraleinheit\u003c\/th\u003e\n              \u003ctd\u003e1148\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eReferenz Sirene\/Blitzleuchte\u003c\/th\u003e\n              \u003ctd\u003e0440\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eReferenz Netzteil\u003c\/th\u003e\n              \u003ctd\u003e0021\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eBestellnummer Schutzabdeckung\u003c\/th\u003e\n              \u003ctd\u003e0185\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eFuente de alimentación del sistema\u003c\/th\u003e\n              \u003ctd\u003e12-24 V CC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eKommunikation\u003c\/th\u003e\n              \u003ctd\u003eRS485 Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAutomatische Kalibrierung\u003c\/th\u003e\n              \u003ctd\u003eMehrmals im Jahr\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSchutzart des Sensors gegen Eindringen\u003c\/th\u003e\n              \u003ctd\u003eIP54\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eTemperatura de funcionamiento del sensor\u003c\/th\u003e\n              \u003ctd\u003eVon -40 °C bis 25 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eVoreingestellte Alarmstufen\u003c\/th\u003e\n              \u003ctd\u003e5000 ppm Hinweis zur Sensibilisierung, 5000 ppm TWA-\/8-h-Alarm, 1,5 % Voralarm, 3,0 % Hauptalarm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAjuste adicional\u003c\/th\u003e\n              \u003ctd\u003eCompensación de altitud\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza tensión nominal\u003c\/th\u003e\n              \u003ctd\u003e18–24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLeistungsaufnahme Sirene\/Blitzleuchte\u003c\/th\u003e\n              \u003ctd\u003eSpitze 80 mA bei 24 V DC Versorgung\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSchallpegel Sirene\/Blitzleuchte\u003c\/th\u003e\n              \u003ctd\u003e110 dB \/ 1 m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza intensidad del flash\u003c\/th\u003e\n              \u003ctd\u003e115 cd\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza frecuencia del flash\u003c\/th\u003e\n              \u003ctd\u003e65\/min\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza temperatura ambiente\u003c\/th\u003e\n              \u003ctd\u003eVon -5 °C bis +50 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirene\/Blitzleuchte Abmessungen\u003c\/th\u003e\n              \u003ctd\u003e134 x 115 x 61 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSirena\/baliza protección\u003c\/th\u003e\n              \u003ctd\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eZentraleinheit Kommunikation\u003c\/th\u003e\n              \u003ctd\u003eRS485, Modbus\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eZentraleinheit Display\u003c\/th\u003e\n              \u003ctd\u003eGrafikdisplay 128 x 64, mit Hintergrundbeleuchtung\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eAkustisches Signal der Zentraleinheit\u003c\/th\u003e\n              \u003ctd\u003e80 dBa (1 m) max.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eUmgebungstemperatur der Zentraleinheit\u003c\/th\u003e\n              \u003ctd\u003eVon 0 bis +40 °C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eZentraleinheit Feuchte\u003c\/th\u003e\n              \u003ctd\u003e0-90 % sin condensación\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eZentraleinheit Abmessungen\u003c\/th\u003e\n              \u003ctd\u003e90 x 161 x 38 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eSchutz der Zentraleinheit\u003c\/th\u003e\n              \u003ctd\u003eIP54 nach TÜV, IP44 nach UL\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eErweiterungskapazität\u003c\/th\u003e\n              \u003ctd\u003eBis zu 12 Sensoren an eine Zentraleinheit anschließbar\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eLieferumfang\u003c\/th\u003e\n              \u003ctd\u003eCO2 Mk90 inkl. 1 blauem 10-m-Kabel und 1 rotem 5-m-Kabel, Stroboskop-Sirene\/Blitzleuchte mit bernsteinfarbenem LED-Glas mit blauem Indikator inkl. 1-m-Kabel und Schild, RJ45-Y-Adapter 1-1, 1-A-Transformator, Steckerverriegelung, Beutel mit 3 Tüllen, 6 Kabelbindern, 24 Schrauben und Dübeln, Schilder, Mk90-Handbuch, Mk90-Kurzanleitung und Schutzabdeckung.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eCertificaciones y cumplimiento\u003c\/th\u003e\n              \u003ctd\u003eCE, UL, DIN6653-2 2015-06, EN55022:2006\/A1:2007, EN55024\/A2:2003, EN61000-3-2:2006, EN61000-3-3\/A2:2006, AS\/NZS CISPR 22:2006, IEC\/EN IT55022\/55024, LNE Règle de certification NF 128.\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGTIN\/EAN\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003cth scope=\"row\"\u003eGewicht\u003c\/th\u003e\n              \u003ctd\u003eDato no facilitado\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eKompatibilität und Anwendungsfälle\u003c\/h2\u003e\n      \u003cp\u003eDieses Set ist für Kühlräume, Tiefkühler, Kaltlagerbereiche, Gasräume im Zusammenhang mit Kühlzellen und andere kalte Innenräume vorgesehen, in denen CO2 verwendet wird und bei Leckagen ein Risiko der Ansammlung besteht.\u003c\/p\u003e\n      \u003cp\u003eGeeignet für Gastronomie, Lebensmitteleinzelhandel, Weinkeller, Brauereien, Getränkehersteller, Lebensmittelindustrie und jede Anlage, in der CO2 in Kühlräumen oder Bereichen mit niedriger Temperatur eingesetzt wird.\u003c\/p\u003e\n      \u003cp\u003eDie Herstellerdokumentation selbst sieht Erweiterungen durch zusätzliche Kits, Relais‑Kits und die Anbindung an Gebäudemanagementsysteme vor – jeweils innerhalb der LogiCO2‑Architektur.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eInstallation und Hinweise vor dem Kauf\u003c\/h2\u003e\n      \u003cul class=\"iblgcr-bullets\"\u003e\n        \u003cli\u003eEl sensor debe instalarse a una altura máxima de 30 cm del suelo y a una distancia máxima de 5 m del punto de distribución de CO2.\u003c\/li\u003e\n        \u003cli\u003eJeder Sensor deckt eine maximale Fläche von 78 m² ab; ist die Kammer oder Zone größer, sollten zusätzliche Sensoren in Betracht gezogen werden.\u003c\/li\u003e\n        \u003cli\u003eDie Sirene\/Blitzleuchte ist über dem Sensor in einer Höhe von ca. 2–2,4 m über dem Boden anzubringen und muss von jedem Eingang aus gut sichtbar sein.\u003c\/li\u003e\n        \u003cli\u003eIn der Dokumentation wird empfohlen, zusätzlich eine zweite Sirene\/Blitzleuchte außerhalb des überwachten Bereichs zu montieren, vorzugsweise über der Tür oder den Zugangstüren.\u003c\/li\u003e\n        \u003cli\u003eDie Zentraleinheit muss außerhalb des überwachten Bereichs an einer gut sichtbaren und zugänglichen Stelle installiert werden.\u003c\/li\u003e\n        \u003cli\u003ePrüfen Sie die verfügbare Versorgungsspannung, die Verlegung der RJ45-Verkabelung und die Systemarchitektur, falls Sie Erweiterungen planen.\u003c\/li\u003e\n        \u003cli\u003eDa es sich um ein Sicherheitsprodukt handelt, müssen Installation und Inbetriebnahme mit technischem Sachverstand und abschließender Funktionsprüfung erfolgen.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-block\"\u003e\n      \u003ch2\u003eEmpfohlene Wartung und Nutzung\u003c\/h2\u003e\n      \u003cp\u003eDer Sensor führt mehrmals im Jahr eine automatische Kalibrierung durch. Da es sich jedoch um ein CO2-Sicherheitssystem handelt, wird empfohlen, Kabel, Verbinder, Sichtbarkeit der Beschilderung, Signalhorn\/Blitzleuchte und korrekte Anzeige an der Zentraleinheit regelmäßig zu überprüfen.\u003c\/p\u003e\n      \u003cp\u003eDie allgemeine Systemdokumentation empfiehlt, dass ein qualifizierter Fachbetrieb mindestens einmal pro Jahr eine Funktionsprüfung durchführt. Die Reinigung sollte mit Wasser und einem angefeuchteten Tuch erfolgen; unbefugte Eingriffe in das Gerät sind zu vermeiden.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-faq\"\u003e\n      \u003ch2\u003eHäufig gestellte Fragen\u003c\/h2\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIst dieses Produkt für Kühl- und Tiefkühlräume geeignet?\u003c\/summary\u003e\n        \u003cp\u003eJa. Artikel 3349 ist speziell für Anwendungen in Kühl- und Tiefkühlräumen ausgelegt.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eIst eine Mk9-Zentraleinheit enthalten?\u003c\/summary\u003e\n        \u003cp\u003eJa. Dieses Basisset umfasst Cold-Room-Sensor, Zentraleinheit Mk9, Signalhorn\/Blitzleuchte, Netzteil, Verbinder, Handbuch und Beschilderung.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWorin unterscheidet er sich von einem herkömmlichen Detektor?\u003c\/summary\u003e\n        \u003cp\u003eIm Datenblatt des Herstellers wird erläutert, dass herkömmliche Detektoren nicht für kalte Umgebungen ausgelegt sind und eine hohe Fehlertoleranz aufweisen können. Dieser Sensor ist für niedrige Temperaturen angepasst.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eWo sollte der Sensor installiert werden?\u003c\/summary\u003e\n        \u003cp\u003eEs muss in maximal 30 cm Höhe über dem Boden und höchstens 5 m vom CO2-Verteilerpunkt entfernt montiert werden. Jeder Sensor deckt bis zu 78 m² ab.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eKann das System erweitert werden?\u003c\/summary\u003e\n        \u003cp\u003eJa. In der Dokumentation zum Artikel 3349 ist angegeben, dass bis zu 12 Sensoren an eine Zentraleinheit angeschlossen werden können und dass Zusatzkits im Plug-and-Play-Modus installiert werden.\u003c\/p\u003e\n      \u003c\/details\u003e\n\n      \u003cdetails\u003e\n        \u003csummary\u003eBenötigt es eine regelmäßige Wartung?\u003c\/summary\u003e\n        \u003cp\u003eJa. Obwohl der Sensor eine automatische Kalibrierung durchführt, sind eine regelmäßige Funktionskontrolle und eine fachkundige Überprüfung mindestens einmal jährlich sinnvoll.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-downloads\"\u003e\n      \u003ch2\u003eDownloadbereich\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-download-grid\"\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/CO2_Coldroom_SensorSET_3349_es_db_LogiCO2.pdf?v=1775036243\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnisches Datenblatt LogiCO2 3349\u003c\/a\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/co2ss_mk9_mk90_es.pdf?v=1772145161\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHandbuch Mk9 \/ Mk90\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"iblgcr-related\"\u003e\n      \u003ch2\u003eTambién puede interesarte\u003c\/h2\u003e\n      \u003cdiv class=\"iblgcr-related-grid\"\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"\/de\/collections\/alarmas-detectores-co2-logico2\"\u003eLogiCO2 CO2‑Alarmgeräte und ‑Melder\u003c\/a\u003e\n        \u003ca class=\"iblgcr-btn\" href=\"\/de\/pages\/servicio-tecnico\"\u003eAsesoramiento e instalación técnica\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e","brand":"LogiCO2","offers":[{"title":"Default Title","offer_id":57238894084444,"sku":"LG007","price":618.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0339\/9513\/files\/coldroom-co2sensor-set-logico2.webp?v=1775036636","url":"https:\/\/installbeer.com\/de\/products\/conjunto-sensores-co2-camaras-frigorificas-logico2-mk90","provider":"Install Beer","version":"1.0","type":"link"}